在仰卧位经皮肾镜取石术中导航整个采集系统:刚性肾镜是否足够?国际尿路结石联盟仰卧位经皮肾镜取石术工作组的前瞻性研究。

IF 1.1 4区 医学 Q3 SURGERY
Mehmet Ilker Gokce, Giorgio Mazzon, Dong Nguyen, Braulio Manzo Perez, Muhammed Arif Ibis, Guohua Zeng, Kemal Sarica
{"title":"在仰卧位经皮肾镜取石术中导航整个采集系统:刚性肾镜是否足够?国际尿路结石联盟仰卧位经皮肾镜取石术工作组的前瞻性研究。","authors":"Mehmet Ilker Gokce, Giorgio Mazzon, Dong Nguyen, Braulio Manzo Perez, Muhammed Arif Ibis, Guohua Zeng, Kemal Sarica","doi":"10.1089/lap.2024.0025","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> During percutaneous nephrolithotomy (PCNL), accessibility to the entire collecting system is crucial to check the presence of any residual stone fragments. In this study, we aimed to identify the rate of accessibility of all caliceal cavities using lower-, middle- and, upper-pole punctures and the eventual benefit of simultaneous utilization of retrograde/antegrade flexible nephroscopy. <b><i>Materials and Methods:</i></b> Data of patients undergone supine PCNL in five different institutions were collected prospectively. Access status to other poles of the kidney with a rigid nephroscope, antegrade access status to the other poles of the kidney with a flexible nephroscope, or retrograde access with a flexible ureterorenoscope were all evaluated together with detection of residual fragments. Access status to the other poles of the kidney with anterograde and retrograde approaches were compared. <b><i>Results:</i></b> Data of 226 patients were analyzed and stone-free status was achieved in 207 (91.6%) of the patients. The entire collecting system could be successfully approached by a rigid nephroscope in 50% of the cases through middle-pole puncture. This rate was significantly higher than that of lower-pole puncture (37.1%) and upper-pole puncture (28.1%) (<i>P</i> = .035). The successful approach to the entire collecting system with retrograde ureterorenoscopy was possible in 97.6% of the cases, while the successful approach was possible in 48 of the 60 cases (80%) with the retrograde approach (<i>P</i> < .0001). <b><i>Conclusions:</i></b> During PCNL, evaluation of the entire collecting system with rigid nephroscopy is not possible in a significant portion of the patients. We believe that the application of flexible nephroscopy, particularly via retrograde approach improves the stone-free rates.</p>","PeriodicalId":50166,"journal":{"name":"Journal of Laparoendoscopic & Advanced Surgical Techniques","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Navigating Entire Collecting System During Supine Percutaneous Nephrolithotomy: Is Rigid Nephroscopy Enough? A Prospective Study by International Alliance of Urolithiasis Supine Percutaneous Nephrolithotomy Working Group.\",\"authors\":\"Mehmet Ilker Gokce, Giorgio Mazzon, Dong Nguyen, Braulio Manzo Perez, Muhammed Arif Ibis, Guohua Zeng, Kemal Sarica\",\"doi\":\"10.1089/lap.2024.0025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Background:</i></b> During percutaneous nephrolithotomy (PCNL), accessibility to the entire collecting system is crucial to check the presence of any residual stone fragments. In this study, we aimed to identify the rate of accessibility of all caliceal cavities using lower-, middle- and, upper-pole punctures and the eventual benefit of simultaneous utilization of retrograde/antegrade flexible nephroscopy. <b><i>Materials and Methods:</i></b> Data of patients undergone supine PCNL in five different institutions were collected prospectively. Access status to other poles of the kidney with a rigid nephroscope, antegrade access status to the other poles of the kidney with a flexible nephroscope, or retrograde access with a flexible ureterorenoscope were all evaluated together with detection of residual fragments. Access status to the other poles of the kidney with anterograde and retrograde approaches were compared. <b><i>Results:</i></b> Data of 226 patients were analyzed and stone-free status was achieved in 207 (91.6%) of the patients. The entire collecting system could be successfully approached by a rigid nephroscope in 50% of the cases through middle-pole puncture. This rate was significantly higher than that of lower-pole puncture (37.1%) and upper-pole puncture (28.1%) (<i>P</i> = .035). The successful approach to the entire collecting system with retrograde ureterorenoscopy was possible in 97.6% of the cases, while the successful approach was possible in 48 of the 60 cases (80%) with the retrograde approach (<i>P</i> < .0001). <b><i>Conclusions:</i></b> During PCNL, evaluation of the entire collecting system with rigid nephroscopy is not possible in a significant portion of the patients. We believe that the application of flexible nephroscopy, particularly via retrograde approach improves the stone-free rates.</p>\",\"PeriodicalId\":50166,\"journal\":{\"name\":\"Journal of Laparoendoscopic & Advanced Surgical Techniques\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Laparoendoscopic & Advanced Surgical Techniques\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/lap.2024.0025\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Laparoendoscopic & Advanced Surgical Techniques","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/lap.2024.0025","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景:在经皮肾镜碎石术(PCNL)中,能否进入整个集合系统对于检查是否存在残余结石碎片至关重要。在本研究中,我们旨在确定使用下极、中极和上极穿刺对所有盏腔的可及性,以及同时使用逆行/顺行柔性肾镜的最终益处。材料和方法:前瞻性地收集了在五家不同机构接受仰卧位 PCNL 的患者数据。对使用硬性肾镜进入肾脏其他两极、使用柔性肾镜前行进入肾脏其他两极或使用柔性输尿管造影镜逆行进入肾脏其他两极的情况以及残留碎片的检测情况进行了评估。比较了前行和逆行方法进入肾脏其他两极的情况。结果:分析了 226 名患者的数据,其中 207 名患者(91.6%)达到了无结石状态。在 50%的病例中,硬质肾镜可通过中极穿刺成功进入整个集合系统。这一比例明显高于下极穿刺(37.1%)和上极穿刺(28.1%)(P = 0.035)。97.6%的病例可以通过逆行输尿管结肠镜成功进入整个集合系统,而采用逆行方法的 60 例病例中有 48 例(80%)可以成功进入集合系统(P 结论:逆行输尿管结肠镜穿刺的成功率高于逆行输尿管结肠镜穿刺的成功率:在 PCNL 期间,相当一部分患者无法通过硬性肾镜对整个集合系统进行评估。我们认为,应用柔性肾镜,尤其是逆行方法,可提高无结石率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Navigating Entire Collecting System During Supine Percutaneous Nephrolithotomy: Is Rigid Nephroscopy Enough? A Prospective Study by International Alliance of Urolithiasis Supine Percutaneous Nephrolithotomy Working Group.

Background: During percutaneous nephrolithotomy (PCNL), accessibility to the entire collecting system is crucial to check the presence of any residual stone fragments. In this study, we aimed to identify the rate of accessibility of all caliceal cavities using lower-, middle- and, upper-pole punctures and the eventual benefit of simultaneous utilization of retrograde/antegrade flexible nephroscopy. Materials and Methods: Data of patients undergone supine PCNL in five different institutions were collected prospectively. Access status to other poles of the kidney with a rigid nephroscope, antegrade access status to the other poles of the kidney with a flexible nephroscope, or retrograde access with a flexible ureterorenoscope were all evaluated together with detection of residual fragments. Access status to the other poles of the kidney with anterograde and retrograde approaches were compared. Results: Data of 226 patients were analyzed and stone-free status was achieved in 207 (91.6%) of the patients. The entire collecting system could be successfully approached by a rigid nephroscope in 50% of the cases through middle-pole puncture. This rate was significantly higher than that of lower-pole puncture (37.1%) and upper-pole puncture (28.1%) (P = .035). The successful approach to the entire collecting system with retrograde ureterorenoscopy was possible in 97.6% of the cases, while the successful approach was possible in 48 of the 60 cases (80%) with the retrograde approach (P < .0001). Conclusions: During PCNL, evaluation of the entire collecting system with rigid nephroscopy is not possible in a significant portion of the patients. We believe that the application of flexible nephroscopy, particularly via retrograde approach improves the stone-free rates.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
163
审稿时长
3 months
期刊介绍: Journal of Laparoendoscopic & Advanced Surgical Techniques (JLAST) is the leading international peer-reviewed journal for practicing surgeons who want to keep up with the latest thinking and advanced surgical technologies in laparoscopy, endoscopy, NOTES, and robotics. The Journal is ideally suited to surgeons who are early adopters of new technology and techniques. Recognizing that many new technologies and techniques have significant overlap with several surgical specialties, JLAST is the first journal to focus on these topics both in general and pediatric surgery, and includes other surgical subspecialties such as: urology, gynecologic surgery, thoracic surgery, and more.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信