{"title":"用于牙科植入物的钛合金的循环疲劳特性。","authors":"Tomofumi Takano, Masao Yoshinari, Kaoru Sakurai, Takayuki Ueda","doi":"10.2209/tdcpublication.2023-0025","DOIUrl":null,"url":null,"abstract":"<p><p>The present study investigated the cyclic fatigue properties of titanium alloys (Ti-6Al-4V and Ti-6Al-7Nb) as implant materials and compared their properties with those of commercially pure titanium. Ti-6Al-4V and Ti-6Al-7Nb cylinders with diameters of 3.0 mm were examined. The surfaces of the cylinders were roughened by sand blasting with alumina particles and acid etching. Static and cyclic tests were performed according to ISO 14801:2016. The yield force in the static test (YS) was measured in 5 specimens of each alloy using a universal testing machine. The yield force in a cyclic test (YC) was measured in 20 specimens of each alloy using the staircase method, which involved applying a cyclic load at a frequency of 10 Hz for 10<sup>6</sup> cycles. After the cyclic loading tests, cross-sections of the specimens were examined under an optical microscope. The YS values for Ti-6Al-4V and Ti-6Al-7Nb were 1463 N±93 N and 1405 N±79 N, respectively, and the YC values were 870 N±58 N and 853 N±202 N, respectively. Microscopic observation revealed cracks on the tensile side of some of the specimens, including run outs and failures. The results of this study suggest that the YC values for Ti-6Al-4V and Ti-6Al-7Nb were 40% less than those for YS. The yield force of Grade-4 Cp-Ti significantly decreased after cyclic loading. The YC values for Ti-6Al-4V and Ti-6Al-7Nb were approximately 900 N, which was markedly greater than that for commercially pure, Grade-4 titanium (700 N).</p>","PeriodicalId":45490,"journal":{"name":"Bulletin of Tokyo Dental College","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2024-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cyclic Fatigue Properties of Titanium Alloys for Application in Dental Implants.\",\"authors\":\"Tomofumi Takano, Masao Yoshinari, Kaoru Sakurai, Takayuki Ueda\",\"doi\":\"10.2209/tdcpublication.2023-0025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present study investigated the cyclic fatigue properties of titanium alloys (Ti-6Al-4V and Ti-6Al-7Nb) as implant materials and compared their properties with those of commercially pure titanium. Ti-6Al-4V and Ti-6Al-7Nb cylinders with diameters of 3.0 mm were examined. The surfaces of the cylinders were roughened by sand blasting with alumina particles and acid etching. Static and cyclic tests were performed according to ISO 14801:2016. The yield force in the static test (YS) was measured in 5 specimens of each alloy using a universal testing machine. The yield force in a cyclic test (YC) was measured in 20 specimens of each alloy using the staircase method, which involved applying a cyclic load at a frequency of 10 Hz for 10<sup>6</sup> cycles. After the cyclic loading tests, cross-sections of the specimens were examined under an optical microscope. The YS values for Ti-6Al-4V and Ti-6Al-7Nb were 1463 N±93 N and 1405 N±79 N, respectively, and the YC values were 870 N±58 N and 853 N±202 N, respectively. Microscopic observation revealed cracks on the tensile side of some of the specimens, including run outs and failures. The results of this study suggest that the YC values for Ti-6Al-4V and Ti-6Al-7Nb were 40% less than those for YS. The yield force of Grade-4 Cp-Ti significantly decreased after cyclic loading. The YC values for Ti-6Al-4V and Ti-6Al-7Nb were approximately 900 N, which was markedly greater than that for commercially pure, Grade-4 titanium (700 N).</p>\",\"PeriodicalId\":45490,\"journal\":{\"name\":\"Bulletin of Tokyo Dental College\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2024-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of Tokyo Dental College\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2209/tdcpublication.2023-0025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Tokyo Dental College","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2209/tdcpublication.2023-0025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/15 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本研究调查了作为植入材料的钛合金(Ti-6Al-4V 和 Ti-6Al-7Nb)的循环疲劳特性,并将其特性与市售纯钛的特性进行了比较。对直径为 3.0 毫米的 Ti-6Al-4V 和 Ti-6Al-7Nb 圆柱体进行了检验。圆柱体的表面通过氧化铝颗粒喷砂和酸蚀刻进行了粗化处理。根据 ISO 14801:2016 标准进行了静态和循环测试。使用万能试验机测量了每种合金的 5 个试样在静态试验中的屈服力(YS)。循环试验中的屈服力(YC)是使用阶梯法对每种合金的 20 个试样进行测量的,其中包括施加频率为 10 Hz 的循环负载,持续 106 个循环。循环加载试验结束后,在光学显微镜下检查试样的横截面。Ti-6Al-4V 和 Ti-6Al-7Nb 的 YS 值分别为 1463 N±93 N 和 1405 N±79 N,YC 值分别为 870 N±58 N 和 853 N±202 N。显微镜观察发现,一些试样的拉伸侧出现了裂纹,包括跑偏和失效。研究结果表明,Ti-6Al-4V 和 Ti-6Al-7Nb 的 YC 值比 YS 值低 40%。4 级 Cp-Ti 的屈服力在循环加载后明显下降。Ti-6Al-4V 和 Ti-6Al-7Nb 的 YC 值约为 900 N,明显高于商业纯 4 级钛的 YC 值(700 N)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cyclic Fatigue Properties of Titanium Alloys for Application in Dental Implants.

The present study investigated the cyclic fatigue properties of titanium alloys (Ti-6Al-4V and Ti-6Al-7Nb) as implant materials and compared their properties with those of commercially pure titanium. Ti-6Al-4V and Ti-6Al-7Nb cylinders with diameters of 3.0 mm were examined. The surfaces of the cylinders were roughened by sand blasting with alumina particles and acid etching. Static and cyclic tests were performed according to ISO 14801:2016. The yield force in the static test (YS) was measured in 5 specimens of each alloy using a universal testing machine. The yield force in a cyclic test (YC) was measured in 20 specimens of each alloy using the staircase method, which involved applying a cyclic load at a frequency of 10 Hz for 106 cycles. After the cyclic loading tests, cross-sections of the specimens were examined under an optical microscope. The YS values for Ti-6Al-4V and Ti-6Al-7Nb were 1463 N±93 N and 1405 N±79 N, respectively, and the YC values were 870 N±58 N and 853 N±202 N, respectively. Microscopic observation revealed cracks on the tensile side of some of the specimens, including run outs and failures. The results of this study suggest that the YC values for Ti-6Al-4V and Ti-6Al-7Nb were 40% less than those for YS. The yield force of Grade-4 Cp-Ti significantly decreased after cyclic loading. The YC values for Ti-6Al-4V and Ti-6Al-7Nb were approximately 900 N, which was markedly greater than that for commercially pure, Grade-4 titanium (700 N).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bulletin of Tokyo Dental College
Bulletin of Tokyo Dental College DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: The bulletin of Tokyo Dental collegue is principally for the publication of original contributions to multidisciplinary research in dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信