Jian Xiong, Jingjing Xu, Mengyun Zhou, Jie Liu, Qing Wang, Xiaolong Yin, Yan Deng, Xiao Luo, Nanye Wang, Fu Gui, Kang Yu, Jueling Liu, Zeyu Zhu, Chiwen Cheng, Yifeng Yu
{"title":"中焦瞳孔指数是眼内植入式准分子人工晶体植入术后产生残疾眩光的潜在风险因素:前瞻性研究。","authors":"Jian Xiong, Jingjing Xu, Mengyun Zhou, Jie Liu, Qing Wang, Xiaolong Yin, Yan Deng, Xiao Luo, Nanye Wang, Fu Gui, Kang Yu, Jueling Liu, Zeyu Zhu, Chiwen Cheng, Yifeng Yu","doi":"10.1097/j.jcrs.0000000000001420","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To explore the influence of preoperative factors, including varying pupil sizes and refractive attributes, on postoperative glare disability in patients undergoing implantable collamer lens (ICL) implantation.</p><p><strong>Setting: </strong>Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China.</p><p><strong>Design: </strong>Prospective observational study.</p><p><strong>Methods: </strong>The preoperative ocular characteristics and 6-month postoperative glare status in eligible patients who underwent EVO-Visian ICL V4c (VICMO) implantation were analyzed. The glare disability criteria encompassed a glare symptom score >6 and glare sensitivity exceeding 1:2.7. Logistic regression analysis was used to explore the relationship between the preoperative ocular parameters and post-ICL glare.</p><p><strong>Results: </strong>The study included 95 patients (mean age, 26.04 ± 6.29 years), comprising 30 men (58 eyes) and 65 women (129 eyes). Multivariate analysis revealed a significant correlation between postoperative glare disability and increased spherical power in preoperative mesopic pupils (β = -0.124, P = .039), as well as elevated cylinder power in preoperative mesopic (β = -0.412, P = .009) and photopic pupils (β = -0.430, P = .007). Moreover, a larger preoperative mesopic pupil diameter (β = 0.561, P = .005) demonstrated a significant correlation with glare disability.</p><p><strong>Conclusions: </strong>Preoperative mesopic pupil dimensions and associated refractive parameters, such as sphere and cylinder, were correlated with glare disability, including the cylinder aspect in photopic pupils, which can assist clinicians in optimizing preoperative selection for ICL implantation, aiding in the anticipation of potential glare disability risks.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"565-571"},"PeriodicalIF":2.6000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11146185/pdf/","citationCount":"0","resultStr":"{\"title\":\"Mesopic pupil indices as potential risk factors for glare disability after intraocular implantable collamer lens implantation: prospective study.\",\"authors\":\"Jian Xiong, Jingjing Xu, Mengyun Zhou, Jie Liu, Qing Wang, Xiaolong Yin, Yan Deng, Xiao Luo, Nanye Wang, Fu Gui, Kang Yu, Jueling Liu, Zeyu Zhu, Chiwen Cheng, Yifeng Yu\",\"doi\":\"10.1097/j.jcrs.0000000000001420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To explore the influence of preoperative factors, including varying pupil sizes and refractive attributes, on postoperative glare disability in patients undergoing implantable collamer lens (ICL) implantation.</p><p><strong>Setting: </strong>Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China.</p><p><strong>Design: </strong>Prospective observational study.</p><p><strong>Methods: </strong>The preoperative ocular characteristics and 6-month postoperative glare status in eligible patients who underwent EVO-Visian ICL V4c (VICMO) implantation were analyzed. The glare disability criteria encompassed a glare symptom score >6 and glare sensitivity exceeding 1:2.7. Logistic regression analysis was used to explore the relationship between the preoperative ocular parameters and post-ICL glare.</p><p><strong>Results: </strong>The study included 95 patients (mean age, 26.04 ± 6.29 years), comprising 30 men (58 eyes) and 65 women (129 eyes). Multivariate analysis revealed a significant correlation between postoperative glare disability and increased spherical power in preoperative mesopic pupils (β = -0.124, P = .039), as well as elevated cylinder power in preoperative mesopic (β = -0.412, P = .009) and photopic pupils (β = -0.430, P = .007). Moreover, a larger preoperative mesopic pupil diameter (β = 0.561, P = .005) demonstrated a significant correlation with glare disability.</p><p><strong>Conclusions: </strong>Preoperative mesopic pupil dimensions and associated refractive parameters, such as sphere and cylinder, were correlated with glare disability, including the cylinder aspect in photopic pupils, which can assist clinicians in optimizing preoperative selection for ICL implantation, aiding in the anticipation of potential glare disability risks.</p>\",\"PeriodicalId\":15214,\"journal\":{\"name\":\"Journal of cataract and refractive surgery\",\"volume\":\" \",\"pages\":\"565-571\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11146185/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cataract and refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcrs.0000000000001420\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001420","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Mesopic pupil indices as potential risk factors for glare disability after intraocular implantable collamer lens implantation: prospective study.
Purpose: To explore the influence of preoperative factors, including varying pupil sizes and refractive attributes, on postoperative glare disability in patients undergoing implantable collamer lens (ICL) implantation.
Setting: Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China.
Design: Prospective observational study.
Methods: The preoperative ocular characteristics and 6-month postoperative glare status in eligible patients who underwent EVO-Visian ICL V4c (VICMO) implantation were analyzed. The glare disability criteria encompassed a glare symptom score >6 and glare sensitivity exceeding 1:2.7. Logistic regression analysis was used to explore the relationship between the preoperative ocular parameters and post-ICL glare.
Results: The study included 95 patients (mean age, 26.04 ± 6.29 years), comprising 30 men (58 eyes) and 65 women (129 eyes). Multivariate analysis revealed a significant correlation between postoperative glare disability and increased spherical power in preoperative mesopic pupils (β = -0.124, P = .039), as well as elevated cylinder power in preoperative mesopic (β = -0.412, P = .009) and photopic pupils (β = -0.430, P = .007). Moreover, a larger preoperative mesopic pupil diameter (β = 0.561, P = .005) demonstrated a significant correlation with glare disability.
Conclusions: Preoperative mesopic pupil dimensions and associated refractive parameters, such as sphere and cylinder, were correlated with glare disability, including the cylinder aspect in photopic pupils, which can assist clinicians in optimizing preoperative selection for ICL implantation, aiding in the anticipation of potential glare disability risks.
期刊介绍:
The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS).
JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.