中焦瞳孔指数是眼内植入式准分子人工晶体植入术后产生残疾眩光的潜在风险因素:前瞻性研究。

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY
Jian Xiong, Jingjing Xu, Mengyun Zhou, Jie Liu, Qing Wang, Xiaolong Yin, Yan Deng, Xiao Luo, Nanye Wang, Fu Gui, Kang Yu, Jueling Liu, Zeyu Zhu, Chiwen Cheng, Yifeng Yu
{"title":"中焦瞳孔指数是眼内植入式准分子人工晶体植入术后产生残疾眩光的潜在风险因素:前瞻性研究。","authors":"Jian Xiong, Jingjing Xu, Mengyun Zhou, Jie Liu, Qing Wang, Xiaolong Yin, Yan Deng, Xiao Luo, Nanye Wang, Fu Gui, Kang Yu, Jueling Liu, Zeyu Zhu, Chiwen Cheng, Yifeng Yu","doi":"10.1097/j.jcrs.0000000000001420","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To explore the influence of preoperative factors, including varying pupil sizes and refractive attributes, on postoperative glare disability in patients undergoing implantable collamer lens (ICL) implantation.</p><p><strong>Setting: </strong>Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China.</p><p><strong>Design: </strong>Prospective observational study.</p><p><strong>Methods: </strong>The preoperative ocular characteristics and 6-month postoperative glare status in eligible patients who underwent EVO-Visian ICL V4c (VICMO) implantation were analyzed. The glare disability criteria encompassed a glare symptom score >6 and glare sensitivity exceeding 1:2.7. Logistic regression analysis was used to explore the relationship between the preoperative ocular parameters and post-ICL glare.</p><p><strong>Results: </strong>The study included 95 patients (mean age, 26.04 ± 6.29 years), comprising 30 men (58 eyes) and 65 women (129 eyes). Multivariate analysis revealed a significant correlation between postoperative glare disability and increased spherical power in preoperative mesopic pupils (β = -0.124, P = .039), as well as elevated cylinder power in preoperative mesopic (β = -0.412, P = .009) and photopic pupils (β = -0.430, P = .007). Moreover, a larger preoperative mesopic pupil diameter (β = 0.561, P = .005) demonstrated a significant correlation with glare disability.</p><p><strong>Conclusions: </strong>Preoperative mesopic pupil dimensions and associated refractive parameters, such as sphere and cylinder, were correlated with glare disability, including the cylinder aspect in photopic pupils, which can assist clinicians in optimizing preoperative selection for ICL implantation, aiding in the anticipation of potential glare disability risks.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"565-571"},"PeriodicalIF":2.6000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11146185/pdf/","citationCount":"0","resultStr":"{\"title\":\"Mesopic pupil indices as potential risk factors for glare disability after intraocular implantable collamer lens implantation: prospective study.\",\"authors\":\"Jian Xiong, Jingjing Xu, Mengyun Zhou, Jie Liu, Qing Wang, Xiaolong Yin, Yan Deng, Xiao Luo, Nanye Wang, Fu Gui, Kang Yu, Jueling Liu, Zeyu Zhu, Chiwen Cheng, Yifeng Yu\",\"doi\":\"10.1097/j.jcrs.0000000000001420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To explore the influence of preoperative factors, including varying pupil sizes and refractive attributes, on postoperative glare disability in patients undergoing implantable collamer lens (ICL) implantation.</p><p><strong>Setting: </strong>Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China.</p><p><strong>Design: </strong>Prospective observational study.</p><p><strong>Methods: </strong>The preoperative ocular characteristics and 6-month postoperative glare status in eligible patients who underwent EVO-Visian ICL V4c (VICMO) implantation were analyzed. The glare disability criteria encompassed a glare symptom score >6 and glare sensitivity exceeding 1:2.7. Logistic regression analysis was used to explore the relationship between the preoperative ocular parameters and post-ICL glare.</p><p><strong>Results: </strong>The study included 95 patients (mean age, 26.04 ± 6.29 years), comprising 30 men (58 eyes) and 65 women (129 eyes). Multivariate analysis revealed a significant correlation between postoperative glare disability and increased spherical power in preoperative mesopic pupils (β = -0.124, P = .039), as well as elevated cylinder power in preoperative mesopic (β = -0.412, P = .009) and photopic pupils (β = -0.430, P = .007). Moreover, a larger preoperative mesopic pupil diameter (β = 0.561, P = .005) demonstrated a significant correlation with glare disability.</p><p><strong>Conclusions: </strong>Preoperative mesopic pupil dimensions and associated refractive parameters, such as sphere and cylinder, were correlated with glare disability, including the cylinder aspect in photopic pupils, which can assist clinicians in optimizing preoperative selection for ICL implantation, aiding in the anticipation of potential glare disability risks.</p>\",\"PeriodicalId\":15214,\"journal\":{\"name\":\"Journal of cataract and refractive surgery\",\"volume\":\" \",\"pages\":\"565-571\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11146185/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cataract and refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcrs.0000000000001420\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001420","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨不同瞳孔大小和屈光属性等术前因素对可植入性人工晶体(ICL)植入术患者术后残疾眩光的影响:南昌大学第二附属医院:前瞻性观察研究:我们分析了接受EVO-Visian ICL V4c (VICMO)植入术的合格患者的术前眼部特征和术后6个月的眩光状况。残疾眩光标准包括眩光症状评分大于 6 分和眩光敏感度超过 1:2.7。采用逻辑回归分析来探讨术前眼部参数与 ICL 术后眩光之间的关系:研究共纳入 95 名患者(平均年龄为 26.04 ± 6.29 岁),其中男性 30 名(58 只眼),女性 65 名(129 只眼)。多变量分析显示,术后残疾眩光与术前中焦瞳孔球面力增加(β = -0.124,p = 0.039)以及术前中焦瞳孔圆柱力增加(β = -0.412,p = 0.009)和近视瞳孔圆柱力增加(β = -0.430,p = 0.007)之间存在显著相关性。此外,术前较大的中焦瞳孔直径(β = 0.561,p = 0.005)与残疾眩光有显著相关性:结论:术前中焦瞳孔尺寸及相关屈光参数(如球面和柱面)与残疾眩光(包括光视瞳孔的柱面)相关,这有助于临床医生优化 ICL 植入术的术前选择,帮助预测潜在的残疾眩光风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mesopic pupil indices as potential risk factors for glare disability after intraocular implantable collamer lens implantation: prospective study.

Purpose: To explore the influence of preoperative factors, including varying pupil sizes and refractive attributes, on postoperative glare disability in patients undergoing implantable collamer lens (ICL) implantation.

Setting: Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China.

Design: Prospective observational study.

Methods: The preoperative ocular characteristics and 6-month postoperative glare status in eligible patients who underwent EVO-Visian ICL V4c (VICMO) implantation were analyzed. The glare disability criteria encompassed a glare symptom score >6 and glare sensitivity exceeding 1:2.7. Logistic regression analysis was used to explore the relationship between the preoperative ocular parameters and post-ICL glare.

Results: The study included 95 patients (mean age, 26.04 ± 6.29 years), comprising 30 men (58 eyes) and 65 women (129 eyes). Multivariate analysis revealed a significant correlation between postoperative glare disability and increased spherical power in preoperative mesopic pupils (β = -0.124, P = .039), as well as elevated cylinder power in preoperative mesopic (β = -0.412, P = .009) and photopic pupils (β = -0.430, P = .007). Moreover, a larger preoperative mesopic pupil diameter (β = 0.561, P = .005) demonstrated a significant correlation with glare disability.

Conclusions: Preoperative mesopic pupil dimensions and associated refractive parameters, such as sphere and cylinder, were correlated with glare disability, including the cylinder aspect in photopic pupils, which can assist clinicians in optimizing preoperative selection for ICL implantation, aiding in the anticipation of potential glare disability risks.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信