治疗有症状的腘动脉病变:戈尔® TIGRIS® 血管支架的讣告。

Thomas Betz, Karin Pfister, Wilma Schierling, Georgios Sachsamanis, Jörn Radunski, Claus Nolte Ernsting, Alexander Stehr
{"title":"治疗有症状的腘动脉病变:戈尔® TIGRIS® 血管支架的讣告。","authors":"Thomas Betz, Karin Pfister, Wilma Schierling, Georgios Sachsamanis, Jörn Radunski, Claus Nolte Ernsting, Alexander Stehr","doi":"10.3233/CH-231993","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The popliteal artery is highly exposed to biomechanical stress, which is the primary factor associated with stent failure. However, information on the optimal endovascular treatment for the popliteal artery is lacking.</p><p><strong>Objective: </strong>To report the efficacy of the GORE® TIGRIS® Vascular Stent for the endovascular treatment of popliteal artery lesions.</p><p><strong>Methods: </strong>Retrospective analysis of all patients with symptoms of peripheral artery occlusive disease (PAD) and popliteal artery lesions who underwent implantation of a GORE® TIGRIS® Vascular Stent between August 2012 and August 2014 at a tertiary vascular centre.</p><p><strong>Results: </strong>Between August 2012 and August 2014, 48 patients (32 men, aged 75±8 years) were treated with a GORE® TIGRIS® Vascular Stent. The technical success rate was 100%. At 12 months, the primary and secondary patency rates were 74% and 85%, respectively. During follow-up, no stent fracture was observed. No major amputations were performed.</p><p><strong>Conclusions: </strong>Our study showed that isolated popliteal artery lesions in patients with symptomatic PAD could easily be treated with the GORE® TIGRIS® Vascular Stent, as good short-term results were achieved at 12 months. Therefore, the discontinuation of this product removed a useful tool with a simple release mechanism from the endovascular armamentarium of vascular specialists.</p>","PeriodicalId":93943,"journal":{"name":"Clinical hemorheology and microcirculation","volume":" ","pages":"67-75"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Treatment of symptomatic popliteal artery lesions: An obituary of the GORE® TIGRIS® vascular stent.\",\"authors\":\"Thomas Betz, Karin Pfister, Wilma Schierling, Georgios Sachsamanis, Jörn Radunski, Claus Nolte Ernsting, Alexander Stehr\",\"doi\":\"10.3233/CH-231993\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The popliteal artery is highly exposed to biomechanical stress, which is the primary factor associated with stent failure. However, information on the optimal endovascular treatment for the popliteal artery is lacking.</p><p><strong>Objective: </strong>To report the efficacy of the GORE® TIGRIS® Vascular Stent for the endovascular treatment of popliteal artery lesions.</p><p><strong>Methods: </strong>Retrospective analysis of all patients with symptoms of peripheral artery occlusive disease (PAD) and popliteal artery lesions who underwent implantation of a GORE® TIGRIS® Vascular Stent between August 2012 and August 2014 at a tertiary vascular centre.</p><p><strong>Results: </strong>Between August 2012 and August 2014, 48 patients (32 men, aged 75±8 years) were treated with a GORE® TIGRIS® Vascular Stent. The technical success rate was 100%. At 12 months, the primary and secondary patency rates were 74% and 85%, respectively. During follow-up, no stent fracture was observed. No major amputations were performed.</p><p><strong>Conclusions: </strong>Our study showed that isolated popliteal artery lesions in patients with symptomatic PAD could easily be treated with the GORE® TIGRIS® Vascular Stent, as good short-term results were achieved at 12 months. Therefore, the discontinuation of this product removed a useful tool with a simple release mechanism from the endovascular armamentarium of vascular specialists.</p>\",\"PeriodicalId\":93943,\"journal\":{\"name\":\"Clinical hemorheology and microcirculation\",\"volume\":\" \",\"pages\":\"67-75\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical hemorheology and microcirculation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3233/CH-231993\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical hemorheology and microcirculation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/CH-231993","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:腘动脉高度暴露于生物力学应力,这是导致支架失效的主要因素。然而,有关腘动脉最佳血管内治疗方法的信息尚缺:报告 GORE® TIGRIS® 血管支架用于腘动脉病变血管内治疗的疗效:方法:对2012年8月至2014年8月期间在一家三级血管中心接受GORE® TIGRIS® 血管支架植入手术的所有有外周动脉闭塞性疾病(PAD)症状和腘动脉病变的患者进行回顾性分析:2012年8月至2014年8月期间,48名患者(32名男性,年龄为75±8岁)接受了GORE® TIGRIS®血管支架治疗。技术成功率为 100%。12 个月时,一次和二次通畅率分别为 74% 和 85%。随访期间,未发现支架断裂。结论:我们的研究表明,有症状的 PAD 患者的孤立性腘动脉病变可以通过 GORE® TIGRIS® 血管支架轻松治疗,12 个月后可获得良好的短期效果。因此,该产品的停产使血管专科医生的血管内治疗手段中失去了一种释放机制简单的有用工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Treatment of symptomatic popliteal artery lesions: An obituary of the GORE® TIGRIS® vascular stent.

Background: The popliteal artery is highly exposed to biomechanical stress, which is the primary factor associated with stent failure. However, information on the optimal endovascular treatment for the popliteal artery is lacking.

Objective: To report the efficacy of the GORE® TIGRIS® Vascular Stent for the endovascular treatment of popliteal artery lesions.

Methods: Retrospective analysis of all patients with symptoms of peripheral artery occlusive disease (PAD) and popliteal artery lesions who underwent implantation of a GORE® TIGRIS® Vascular Stent between August 2012 and August 2014 at a tertiary vascular centre.

Results: Between August 2012 and August 2014, 48 patients (32 men, aged 75±8 years) were treated with a GORE® TIGRIS® Vascular Stent. The technical success rate was 100%. At 12 months, the primary and secondary patency rates were 74% and 85%, respectively. During follow-up, no stent fracture was observed. No major amputations were performed.

Conclusions: Our study showed that isolated popliteal artery lesions in patients with symptomatic PAD could easily be treated with the GORE® TIGRIS® Vascular Stent, as good short-term results were achieved at 12 months. Therefore, the discontinuation of this product removed a useful tool with a simple release mechanism from the endovascular armamentarium of vascular specialists.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信