暴露于聚合物或肝素涂层膜氧合器的血液中的血小板体积指数和 von Willebrand 因子水平。

IF 1.4 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Masashi Tagaya, Shinya Okano, Takuo Murataka, Hiroki Handa, Shunsuke Ichikawa, Shunsuke Takahashi
{"title":"暴露于聚合物或肝素涂层膜氧合器的血液中的血小板体积指数和 von Willebrand 因子水平。","authors":"Masashi Tagaya, Shinya Okano, Takuo Murataka, Hiroki Handa, Shunsuke Ichikawa, Shunsuke Takahashi","doi":"10.1177/03913988231223360","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>To understand the behavior of platelet volume indices and the von Willebrand factor (VWF), in vitro experiments using whole human blood were performed with extracorporeal circulation (ECC) circuits, including membrane oxygenators coated with acrylate copolymer (ACP) or immobilized heparin (IHP).</p><p><strong>Methods: </strong>Heparinized blood was circulated through two distinct experimental circuits: an ACP-coated reservoir and tubes, as well as membranes coated with either ACP or IHP (comprising five pieces of each type). The platelet distribution width, mean platelet volume (MPV), platelet large cell ratio (P-LCR), VWF quantity (VWFQ), and VWF activity (VWFA) were measured at 0, 8, 16, 24, and 32 h in each experiment. A two-way analysis of variance (ANOVA) was performed to determine whether the coating type or circulation duration affected the transition of each measurement.</p><p><strong>Results: </strong>Two-way ANOVA indicated that the transitions of MPV, P-LCR, and VWFA were significantly affected by the circulation duration (<i>p</i> = 0.030, 0.001, and <0.001, respectively) and that the transitions of VWFQ and VWFA were significantly affected by the coating type (<i>p</i> = 0.022 and 0.006, respectively). Factor interactions between the coating type and circulation duration were not observed for each transition (<i>p</i> > 0.05).</p><p><strong>Conclusions: </strong>Our findings suggest that P-LCR is a good index for platelet activation in blood-circulating ECC and that VWFA and VWFQ are significantly attenuated in blood-circulating ECC with ACP-coated membranes, indicating the advantage of IHP coating regarding platelet activation.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":" ","pages":"198-204"},"PeriodicalIF":1.4000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Platelet volume indices and von Willebrand factor levels in blood exposed to polymer- or heparin-coated membrane oxygenators.\",\"authors\":\"Masashi Tagaya, Shinya Okano, Takuo Murataka, Hiroki Handa, Shunsuke Ichikawa, Shunsuke Takahashi\",\"doi\":\"10.1177/03913988231223360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>To understand the behavior of platelet volume indices and the von Willebrand factor (VWF), in vitro experiments using whole human blood were performed with extracorporeal circulation (ECC) circuits, including membrane oxygenators coated with acrylate copolymer (ACP) or immobilized heparin (IHP).</p><p><strong>Methods: </strong>Heparinized blood was circulated through two distinct experimental circuits: an ACP-coated reservoir and tubes, as well as membranes coated with either ACP or IHP (comprising five pieces of each type). The platelet distribution width, mean platelet volume (MPV), platelet large cell ratio (P-LCR), VWF quantity (VWFQ), and VWF activity (VWFA) were measured at 0, 8, 16, 24, and 32 h in each experiment. A two-way analysis of variance (ANOVA) was performed to determine whether the coating type or circulation duration affected the transition of each measurement.</p><p><strong>Results: </strong>Two-way ANOVA indicated that the transitions of MPV, P-LCR, and VWFA were significantly affected by the circulation duration (<i>p</i> = 0.030, 0.001, and <0.001, respectively) and that the transitions of VWFQ and VWFA were significantly affected by the coating type (<i>p</i> = 0.022 and 0.006, respectively). Factor interactions between the coating type and circulation duration were not observed for each transition (<i>p</i> > 0.05).</p><p><strong>Conclusions: </strong>Our findings suggest that P-LCR is a good index for platelet activation in blood-circulating ECC and that VWFA and VWFQ are significantly attenuated in blood-circulating ECC with ACP-coated membranes, indicating the advantage of IHP coating regarding platelet activation.</p>\",\"PeriodicalId\":13932,\"journal\":{\"name\":\"International Journal of Artificial Organs\",\"volume\":\" \",\"pages\":\"198-204\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/03913988231223360\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988231223360","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/7 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

简介为了了解血小板体积指数和冯-威廉因子(VWF)的行为,使用体外循环(ECC)回路(包括涂有丙烯酸酯共聚物(ACP)或固定肝素(IHP)的膜氧合器)对全人血进行了体外实验。方法:肝素化血液通过两种不同的实验回路进行循环:涂有 ACP 的储液器和试管,以及涂有 ACP 或 IHP 的膜(每种类型各五片)。每次实验分别在 0、8、16、24 和 32 小时测量血小板分布宽度、平均血小板体积 (MPV)、血小板大细胞比率 (P-LCR)、VWF 数量 (VWFQ) 和 VWF 活性 (VWFA)。进行了双向方差分析(ANOVA),以确定涂层类型或循环持续时间是否会影响各项测量的转换:结果:双向方差分析表明,MPV、P-LCR 和 VWFA 的转变受循环持续时间的显著影响(分别为 p = 0.030、0.001 和 p = 0.022 和 0.006)。没有观察到涂层类型与循环持续时间之间的因子相互作用(p > 0.05):我们的研究结果表明,P-LCR 是血液循环 ECC 中血小板活化的良好指标,而在使用 ACP 涂层膜的血液循环 ECC 中,VWFA 和 VWFQ 明显减弱,这表明 IHP 涂层在血小板活化方面具有优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Platelet volume indices and von Willebrand factor levels in blood exposed to polymer- or heparin-coated membrane oxygenators.

Introduction: To understand the behavior of platelet volume indices and the von Willebrand factor (VWF), in vitro experiments using whole human blood were performed with extracorporeal circulation (ECC) circuits, including membrane oxygenators coated with acrylate copolymer (ACP) or immobilized heparin (IHP).

Methods: Heparinized blood was circulated through two distinct experimental circuits: an ACP-coated reservoir and tubes, as well as membranes coated with either ACP or IHP (comprising five pieces of each type). The platelet distribution width, mean platelet volume (MPV), platelet large cell ratio (P-LCR), VWF quantity (VWFQ), and VWF activity (VWFA) were measured at 0, 8, 16, 24, and 32 h in each experiment. A two-way analysis of variance (ANOVA) was performed to determine whether the coating type or circulation duration affected the transition of each measurement.

Results: Two-way ANOVA indicated that the transitions of MPV, P-LCR, and VWFA were significantly affected by the circulation duration (p = 0.030, 0.001, and <0.001, respectively) and that the transitions of VWFQ and VWFA were significantly affected by the coating type (p = 0.022 and 0.006, respectively). Factor interactions between the coating type and circulation duration were not observed for each transition (p > 0.05).

Conclusions: Our findings suggest that P-LCR is a good index for platelet activation in blood-circulating ECC and that VWFA and VWFQ are significantly attenuated in blood-circulating ECC with ACP-coated membranes, indicating the advantage of IHP coating regarding platelet activation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Artificial Organs
International Journal of Artificial Organs 医学-工程:生物医学
CiteScore
3.40
自引率
5.90%
发文量
92
审稿时长
3 months
期刊介绍: The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信