Iman A El-Asfahani, Amr S Ramdan, Emad M T M Agamy
{"title":"选择性激光熔融杆固位下颌种植体辅助覆盖义齿的准确性:不同印模材料和技术的体外比较。","authors":"Iman A El-Asfahani, Amr S Ramdan, Emad M T M Agamy","doi":"10.1563/aaid-joi-D-23-00068","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to assess the accuracy of the marginal fit of 2 implant-supported overdenture bars fabricated with selective laser melting technology, using polyvinyl siloxane and vinyl siloxane ether impression materials and different impression techniques. Two implants with multi-unit abutments were inserted in a 3D-printed mandibular model and used as a reference model, then duplicated into a stone cast to fabricate custom trays for obtaining impressions with polyvinyl siloxane and vinyl siloxane ether impression materials, using both open and closed-tray techniques. This resulted in a total of 4 groups, each with 8 specimens. The impressions were poured and scanned, and 32 cobalt-chromium bars were fabricated using selective laser melting technology. Each bar was screwed onto one abutment of the reference model, and a standardized digital periapical radiograph of the opposite unscrewed side was taken; this process was repeated to the other abutment. The vertical misfit was measured at 3 predetermined positions on the unscrewed side, and 6 values per bar were recorded. The mean gap distance was measured, and the data were subjected to statistical analysis; the present study found that the open-tray technique with vinyl polyether siloxane impression material may offer improved accuracy for obtaining impressions for 2 implant-supported bars. The open-tray technique groups also showed better marginal fit than the closed-tray groups. However, further clinical research is required to confirm these findings.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"590-598"},"PeriodicalIF":1.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of Selective Laser Melted Bar Retaining Mandibular Implant-Assisted Overdenture: An In Vitro Comparison of Different Impression Materials and Techniques.\",\"authors\":\"Iman A El-Asfahani, Amr S Ramdan, Emad M T M Agamy\",\"doi\":\"10.1563/aaid-joi-D-23-00068\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to assess the accuracy of the marginal fit of 2 implant-supported overdenture bars fabricated with selective laser melting technology, using polyvinyl siloxane and vinyl siloxane ether impression materials and different impression techniques. Two implants with multi-unit abutments were inserted in a 3D-printed mandibular model and used as a reference model, then duplicated into a stone cast to fabricate custom trays for obtaining impressions with polyvinyl siloxane and vinyl siloxane ether impression materials, using both open and closed-tray techniques. This resulted in a total of 4 groups, each with 8 specimens. The impressions were poured and scanned, and 32 cobalt-chromium bars were fabricated using selective laser melting technology. Each bar was screwed onto one abutment of the reference model, and a standardized digital periapical radiograph of the opposite unscrewed side was taken; this process was repeated to the other abutment. The vertical misfit was measured at 3 predetermined positions on the unscrewed side, and 6 values per bar were recorded. The mean gap distance was measured, and the data were subjected to statistical analysis; the present study found that the open-tray technique with vinyl polyether siloxane impression material may offer improved accuracy for obtaining impressions for 2 implant-supported bars. The open-tray technique groups also showed better marginal fit than the closed-tray groups. However, further clinical research is required to confirm these findings.</p>\",\"PeriodicalId\":50101,\"journal\":{\"name\":\"Journal of Oral Implantology\",\"volume\":\" \",\"pages\":\"590-598\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Oral Implantology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1563/aaid-joi-D-23-00068\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oral Implantology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-23-00068","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Accuracy of Selective Laser Melted Bar Retaining Mandibular Implant-Assisted Overdenture: An In Vitro Comparison of Different Impression Materials and Techniques.
This study aimed to assess the accuracy of the marginal fit of 2 implant-supported overdenture bars fabricated with selective laser melting technology, using polyvinyl siloxane and vinyl siloxane ether impression materials and different impression techniques. Two implants with multi-unit abutments were inserted in a 3D-printed mandibular model and used as a reference model, then duplicated into a stone cast to fabricate custom trays for obtaining impressions with polyvinyl siloxane and vinyl siloxane ether impression materials, using both open and closed-tray techniques. This resulted in a total of 4 groups, each with 8 specimens. The impressions were poured and scanned, and 32 cobalt-chromium bars were fabricated using selective laser melting technology. Each bar was screwed onto one abutment of the reference model, and a standardized digital periapical radiograph of the opposite unscrewed side was taken; this process was repeated to the other abutment. The vertical misfit was measured at 3 predetermined positions on the unscrewed side, and 6 values per bar were recorded. The mean gap distance was measured, and the data were subjected to statistical analysis; the present study found that the open-tray technique with vinyl polyether siloxane impression material may offer improved accuracy for obtaining impressions for 2 implant-supported bars. The open-tray technique groups also showed better marginal fit than the closed-tray groups. However, further clinical research is required to confirm these findings.
期刊介绍:
The official publication of the American Academy of Implant Dentistry and of the American Academy of Implant Prosthodontics, is dedicated to providing valuable information to general dentists, oral surgeons, prosthodontists, periodontists, scientists, clinicians, laboratory owners and technicians, manufacturers, and educators. Implant basics, prosthetics, pharmaceuticals, the latest research in implantology, implant surgery, and advanced implant procedures are just some of the topics covered.