自然条件下的薄膜光伏热电池实验研究

IF 1.204 Q3 Energy
I. R. Jurayev, I. A. Yuldoshev, Z. I. Jurayeva
{"title":"自然条件下的薄膜光伏热电池实验研究","authors":"I. R. Jurayev,&nbsp;I. A. Yuldoshev,&nbsp;Z. I. Jurayeva","doi":"10.3103/S0003701X23601278","DOIUrl":null,"url":null,"abstract":"<p>This article presents the results of an experimental study of a photovoltaic thermal battery (PVTB) and a photovoltaic module (PVM) based on a thin-film structure installed on the heliopolygon of the Department of Alternative Energy Sources (AESs) of Tashkent State Technical University. A brief review of research on PVM cooling technologies and the creation of PVTB installations has been conducted. The data from the experimental study were processed. The dynamics of changes in the external parameters and characteristics of PVM and PVTB are presented graphically, as well as a comparison of the values of the corresponding parameters are given in tabular form. According to the results of the conducted research, the surface temperature of the PVTB decreased by an average of 6.3°С relative to the temperature of the PVM. Due to the developed module cooling technology, the electrical power of the PVTB compared to the power of the PVM increased by an average of 5.3 watts or 10.3%. According to experimental data, 122 L of heated water was produced during the time of the experiment from a useful area of 0.7 m<sup>2</sup> of PVTB, with an average temperature of 38.1°C. This installation allows for simultaneous electricity generation and water heating. These advantages create conditions for the use of this installation in the power supply and heated water supply of household needs of consumers.</p>","PeriodicalId":475,"journal":{"name":"Applied Solar Energy","volume":"59 4","pages":"498 - 506"},"PeriodicalIF":1.2040,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Study of a Thin-Film Photovoltaic Thermal Battery in Natural Conditions\",\"authors\":\"I. R. Jurayev,&nbsp;I. A. Yuldoshev,&nbsp;Z. I. Jurayeva\",\"doi\":\"10.3103/S0003701X23601278\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This article presents the results of an experimental study of a photovoltaic thermal battery (PVTB) and a photovoltaic module (PVM) based on a thin-film structure installed on the heliopolygon of the Department of Alternative Energy Sources (AESs) of Tashkent State Technical University. A brief review of research on PVM cooling technologies and the creation of PVTB installations has been conducted. The data from the experimental study were processed. The dynamics of changes in the external parameters and characteristics of PVM and PVTB are presented graphically, as well as a comparison of the values of the corresponding parameters are given in tabular form. According to the results of the conducted research, the surface temperature of the PVTB decreased by an average of 6.3°С relative to the temperature of the PVM. Due to the developed module cooling technology, the electrical power of the PVTB compared to the power of the PVM increased by an average of 5.3 watts or 10.3%. According to experimental data, 122 L of heated water was produced during the time of the experiment from a useful area of 0.7 m<sup>2</sup> of PVTB, with an average temperature of 38.1°C. This installation allows for simultaneous electricity generation and water heating. These advantages create conditions for the use of this installation in the power supply and heated water supply of household needs of consumers.</p>\",\"PeriodicalId\":475,\"journal\":{\"name\":\"Applied Solar Energy\",\"volume\":\"59 4\",\"pages\":\"498 - 506\"},\"PeriodicalIF\":1.2040,\"publicationDate\":\"2024-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Solar Energy\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://link.springer.com/article/10.3103/S0003701X23601278\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Solar Energy","FirstCategoryId":"1","ListUrlMain":"https://link.springer.com/article/10.3103/S0003701X23601278","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
引用次数: 0

摘要

摘要 本文介绍了对安装在塔什干国立技术大学替代能源系(AESs)日光垄上的光伏热电池(PVTB)和基于薄膜结构的光伏模块(PVM)进行实验研究的结果。本文简要回顾了有关 PVM 冷却技术的研究和 PVTB 装置的创建。对实验研究的数据进行了处理。PVM 和 PVTB 外部参数和特性的动态变化以图表形式呈现,相应参数值的比较以表格形式给出。研究结果表明,相对于 PVM 的温度,PVTB 的表面温度平均下降了 6.3°С。由于开发了组件冷却技术,PVTB 的电功率与 PVM 的电功率相比平均增加了 5.3 瓦或 10.3%。实验数据显示,在实验期间,0.7 平方米的 PVTB 有效面积产生了 122 升热水,平均温度为 38.1°C。该装置可同时发电和加热水。这些优势为将该装置用于满足消费者的家庭供电和热水供应需求创造了条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Experimental Study of a Thin-Film Photovoltaic Thermal Battery in Natural Conditions

Experimental Study of a Thin-Film Photovoltaic Thermal Battery in Natural Conditions

Experimental Study of a Thin-Film Photovoltaic Thermal Battery in Natural Conditions

This article presents the results of an experimental study of a photovoltaic thermal battery (PVTB) and a photovoltaic module (PVM) based on a thin-film structure installed on the heliopolygon of the Department of Alternative Energy Sources (AESs) of Tashkent State Technical University. A brief review of research on PVM cooling technologies and the creation of PVTB installations has been conducted. The data from the experimental study were processed. The dynamics of changes in the external parameters and characteristics of PVM and PVTB are presented graphically, as well as a comparison of the values of the corresponding parameters are given in tabular form. According to the results of the conducted research, the surface temperature of the PVTB decreased by an average of 6.3°С relative to the temperature of the PVM. Due to the developed module cooling technology, the electrical power of the PVTB compared to the power of the PVM increased by an average of 5.3 watts or 10.3%. According to experimental data, 122 L of heated water was produced during the time of the experiment from a useful area of 0.7 m2 of PVTB, with an average temperature of 38.1°C. This installation allows for simultaneous electricity generation and water heating. These advantages create conditions for the use of this installation in the power supply and heated water supply of household needs of consumers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Solar Energy
Applied Solar Energy Energy-Renewable Energy, Sustainability and the Environment
CiteScore
2.50
自引率
0.00%
发文量
0
期刊介绍: Applied Solar Energy  is an international peer reviewed journal covers various topics of research and development studies on solar energy conversion and use: photovoltaics, thermophotovoltaics, water heaters, passive solar heating systems, drying of agricultural production, water desalination, solar radiation condensers, operation of Big Solar Oven, combined use of solar energy and traditional energy sources, new semiconductors for solar cells and thermophotovoltaic system photocells, engines for autonomous solar stations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信