用于治疗颅内剥脱性动脉瘤的血流分流器:安全性和有效性的系统回顾和荟萃分析。

IF 4.5 1区 医学 Q1 NEUROIMAGING
Melika Amoukhteh, Amir Hassankhani, Parya Valizadeh, Payam Jannatdoust, Sherief Ghozy, Hassan Kobeissi, David F Kallmes
{"title":"用于治疗颅内剥脱性动脉瘤的血流分流器:安全性和有效性的系统回顾和荟萃分析。","authors":"Melika Amoukhteh, Amir Hassankhani, Parya Valizadeh, Payam Jannatdoust, Sherief Ghozy, Hassan Kobeissi, David F Kallmes","doi":"10.1136/jnis-2023-021117","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Intracranial dissecting aneurysms present clinical challenges, demanding immediate intervention due to their high bleeding risk. While traditional treatments have limitations, the potential of flow diverters shows promise but remains a subject of ongoing debate for optimal management. The aim of this study was assess the safety and efficacy of flow diverters in the treatment of intracranial dissecting aneurysms.</p><p><strong>Methods: </strong>A systematic review and meta-analysis was performed following established guidelines. The search encompassed PubMed, Scopus, Web of Science, and Embase databases up to July 20, 2023. Eligible studies reporting outcomes of interest were included, and relevant data were extracted and analyzed using R software.</p><p><strong>Results: </strong>The analysis, based on data pooled from 20 included studies involving 329 patients, revealed a favorable functional outcome rate of 89.7% at the last follow-up. The mortality rate during the follow-up period was 2.4%, decreasing to 0.9% when excluding the outlier study. In the final angiographic follow-up, a complete occlusion rate of 71.7% and an adequate occlusion rate of 88.3% were observed. Notably, studies with longer angiographic follow-up times exhibited lower rates of complete (P=0.02) and adequate (P<0.01) occlusion. A minimal aneurysm recurrence/rebleeding rate of 0.1% was noted, while in-stent stenosis/thrombosis occurred at a rate of 1.14%. Additionally, ischemic events/infarctions were seen in 3.3% of cases. The need for retreatment was minimal, with a rate of 0.9%, and the technical success rate was impressively high at 99.1%.</p><p><strong>Conclusion: </strong>This study highlights the safety and efficacy of flow diverters in treating intracranial dissecting aneurysms. Further research, encompassing larger multicenter studies with extended follow-up periods, is crucial for comprehending occlusion dynamics, refining treatment strategies, improving long-term outcomes, and addressing methodological limitations.</p>","PeriodicalId":16411,"journal":{"name":"Journal of NeuroInterventional Surgery","volume":null,"pages":null},"PeriodicalIF":4.5000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flow diverters in the treatment of intracranial dissecting aneurysms: a systematic review and meta-analysis of safety and efficacy.\",\"authors\":\"Melika Amoukhteh, Amir Hassankhani, Parya Valizadeh, Payam Jannatdoust, Sherief Ghozy, Hassan Kobeissi, David F Kallmes\",\"doi\":\"10.1136/jnis-2023-021117\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Intracranial dissecting aneurysms present clinical challenges, demanding immediate intervention due to their high bleeding risk. While traditional treatments have limitations, the potential of flow diverters shows promise but remains a subject of ongoing debate for optimal management. The aim of this study was assess the safety and efficacy of flow diverters in the treatment of intracranial dissecting aneurysms.</p><p><strong>Methods: </strong>A systematic review and meta-analysis was performed following established guidelines. The search encompassed PubMed, Scopus, Web of Science, and Embase databases up to July 20, 2023. Eligible studies reporting outcomes of interest were included, and relevant data were extracted and analyzed using R software.</p><p><strong>Results: </strong>The analysis, based on data pooled from 20 included studies involving 329 patients, revealed a favorable functional outcome rate of 89.7% at the last follow-up. The mortality rate during the follow-up period was 2.4%, decreasing to 0.9% when excluding the outlier study. In the final angiographic follow-up, a complete occlusion rate of 71.7% and an adequate occlusion rate of 88.3% were observed. Notably, studies with longer angiographic follow-up times exhibited lower rates of complete (P=0.02) and adequate (P<0.01) occlusion. A minimal aneurysm recurrence/rebleeding rate of 0.1% was noted, while in-stent stenosis/thrombosis occurred at a rate of 1.14%. Additionally, ischemic events/infarctions were seen in 3.3% of cases. The need for retreatment was minimal, with a rate of 0.9%, and the technical success rate was impressively high at 99.1%.</p><p><strong>Conclusion: </strong>This study highlights the safety and efficacy of flow diverters in treating intracranial dissecting aneurysms. Further research, encompassing larger multicenter studies with extended follow-up periods, is crucial for comprehending occlusion dynamics, refining treatment strategies, improving long-term outcomes, and addressing methodological limitations.</p>\",\"PeriodicalId\":16411,\"journal\":{\"name\":\"Journal of NeuroInterventional Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.5000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of NeuroInterventional Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/jnis-2023-021117\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"NEUROIMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NeuroInterventional Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/jnis-2023-021117","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:颅内剥离动脉瘤给临床带来了挑战,由于出血风险高,需要立即进行干预。虽然传统治疗方法有其局限性,但血流分流器的潜力已初露端倪,但如何进行最佳治疗仍是一个争论不休的话题。本研究旨在评估血流分流器治疗颅内剥脱性动脉瘤的安全性和有效性:方法:按照既定指南进行了系统回顾和荟萃分析。检索范围包括截至 2023 年 7 月 20 日的 PubMed、Scopus、Web of Science 和 Embase 数据库。纳入了报告相关结果的合格研究,并使用 R 软件提取和分析了相关数据:结果:根据20项纳入研究(涉及329名患者)的汇总数据进行的分析表明,在最后一次随访中,患者的良好功能预后率为89.7%。随访期间的死亡率为2.4%,剔除离群研究后降至0.9%。在最后的血管造影随访中,完全闭塞率为 71.7%,充分闭塞率为 88.3%。值得注意的是,血管造影随访时间较长的研究显示出较低的完全闭塞率(P=0.02)和充分闭塞率(P=0.01):本研究强调了血流分流器治疗颅内剥脱性动脉瘤的安全性和有效性。进一步的研究,包括更大规模的多中心研究和更长的随访时间,对于理解闭塞动态、完善治疗策略、改善长期疗效和解决方法学上的局限性至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Flow diverters in the treatment of intracranial dissecting aneurysms: a systematic review and meta-analysis of safety and efficacy.

Background: Intracranial dissecting aneurysms present clinical challenges, demanding immediate intervention due to their high bleeding risk. While traditional treatments have limitations, the potential of flow diverters shows promise but remains a subject of ongoing debate for optimal management. The aim of this study was assess the safety and efficacy of flow diverters in the treatment of intracranial dissecting aneurysms.

Methods: A systematic review and meta-analysis was performed following established guidelines. The search encompassed PubMed, Scopus, Web of Science, and Embase databases up to July 20, 2023. Eligible studies reporting outcomes of interest were included, and relevant data were extracted and analyzed using R software.

Results: The analysis, based on data pooled from 20 included studies involving 329 patients, revealed a favorable functional outcome rate of 89.7% at the last follow-up. The mortality rate during the follow-up period was 2.4%, decreasing to 0.9% when excluding the outlier study. In the final angiographic follow-up, a complete occlusion rate of 71.7% and an adequate occlusion rate of 88.3% were observed. Notably, studies with longer angiographic follow-up times exhibited lower rates of complete (P=0.02) and adequate (P<0.01) occlusion. A minimal aneurysm recurrence/rebleeding rate of 0.1% was noted, while in-stent stenosis/thrombosis occurred at a rate of 1.14%. Additionally, ischemic events/infarctions were seen in 3.3% of cases. The need for retreatment was minimal, with a rate of 0.9%, and the technical success rate was impressively high at 99.1%.

Conclusion: This study highlights the safety and efficacy of flow diverters in treating intracranial dissecting aneurysms. Further research, encompassing larger multicenter studies with extended follow-up periods, is crucial for comprehending occlusion dynamics, refining treatment strategies, improving long-term outcomes, and addressing methodological limitations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.50
自引率
14.60%
发文量
291
审稿时长
4-8 weeks
期刊介绍: The Journal of NeuroInterventional Surgery (JNIS) is a leading peer review journal for scientific research and literature pertaining to the field of neurointerventional surgery. The journal launch follows growing professional interest in neurointerventional techniques for the treatment of a range of neurological and vascular problems including stroke, aneurysms, brain tumors, and spinal compression.The journal is owned by SNIS and is also the official journal of the Interventional Chapter of the Australian and New Zealand Society of Neuroradiology (ANZSNR), the Canadian Interventional Neuro Group, the Hong Kong Neurological Society (HKNS) and the Neuroradiological Society of Taiwan.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信