在早产儿视网膜病变筛查中采用光学相干断层扫描技术。

IF 3 2区 医学 Q1 OPHTHALMOLOGY
Current Opinion in Ophthalmology Pub Date : 2024-05-01 Epub Date: 2024-01-11 DOI:10.1097/ICU.0000000000001030
Adam M Hanif, Yifan Jian, Benjamin K Young, John Peter Campbell
{"title":"在早产儿视网膜病变筛查中采用光学相干断层扫描技术。","authors":"Adam M Hanif, Yifan Jian, Benjamin K Young, John Peter Campbell","doi":"10.1097/ICU.0000000000001030","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>In this review, we explore the investigational applications of optical coherence tomography (OCT) in retinopathy of prematurity (ROP), the insights they have delivered thus far, and key milestones for its integration into the standard of care.</p><p><strong>Recent findings: </strong>While OCT has been widely integrated into clinical management of common retinal diseases, its use in pediatric contexts has been undermined by limitations in ergonomics, image acquisition time, and field of view. Recently, investigational handheld OCT devices have been reported with advancements including ultra-widefield view, noncontact use, and high-speed image capture permitting real-time en face visualization. These developments are compelling for OCT as a more objective alternative with reduced neonatal stress compared to indirect ophthalmoscopy and/or fundus photography as a means of classifying and monitoring ROP.</p><p><strong>Summary: </strong>OCT may become a viable modality in management of ROP. Ongoing innovation surrounding handheld devices should aim to optimize patient comfort and image resolution in the retinal periphery. Future clinical investigations may seek to objectively characterize features of peripheral stage and explore novel biomarkers of disease activity.</p>","PeriodicalId":50604,"journal":{"name":"Current Opinion in Ophthalmology","volume":" ","pages":"252-259"},"PeriodicalIF":3.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11034813/pdf/","citationCount":"0","resultStr":"{\"title\":\"Implementation of optical coherence tomography in retinopathy of prematurity screening.\",\"authors\":\"Adam M Hanif, Yifan Jian, Benjamin K Young, John Peter Campbell\",\"doi\":\"10.1097/ICU.0000000000001030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose of review: </strong>In this review, we explore the investigational applications of optical coherence tomography (OCT) in retinopathy of prematurity (ROP), the insights they have delivered thus far, and key milestones for its integration into the standard of care.</p><p><strong>Recent findings: </strong>While OCT has been widely integrated into clinical management of common retinal diseases, its use in pediatric contexts has been undermined by limitations in ergonomics, image acquisition time, and field of view. Recently, investigational handheld OCT devices have been reported with advancements including ultra-widefield view, noncontact use, and high-speed image capture permitting real-time en face visualization. These developments are compelling for OCT as a more objective alternative with reduced neonatal stress compared to indirect ophthalmoscopy and/or fundus photography as a means of classifying and monitoring ROP.</p><p><strong>Summary: </strong>OCT may become a viable modality in management of ROP. Ongoing innovation surrounding handheld devices should aim to optimize patient comfort and image resolution in the retinal periphery. Future clinical investigations may seek to objectively characterize features of peripheral stage and explore novel biomarkers of disease activity.</p>\",\"PeriodicalId\":50604,\"journal\":{\"name\":\"Current Opinion in Ophthalmology\",\"volume\":\" \",\"pages\":\"252-259\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11034813/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Opinion in Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICU.0000000000001030\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Opinion in Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICU.0000000000001030","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/11 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

综述的目的:在这篇综述中,我们探讨了光学相干断层扫描(OCT)在早产儿视网膜病变(ROP)中的研究性应用、迄今为止所获得的见解以及将其纳入标准治疗的关键里程碑:最近的研究结果:虽然 OCT 已被广泛应用于常见视网膜疾病的临床治疗,但由于其在人体工程学、图像采集时间和视野方面的局限性,其在儿科领域的应用一直受到影响。最近,有研究报告称,手持式 OCT 设备取得了一些进步,包括超宽视野、非接触式使用和高速图像捕捉,从而实现了实时全脸可视化。与间接眼底镜检查和/或眼底照相相比,OCT 是一种更客观的替代方法,可减少新生儿的压力,从而对 ROP 进行分类和监测。围绕手持设备的不断创新应旨在优化患者的舒适度和视网膜周边的图像分辨率。未来的临床研究可能会寻求客观描述周边阶段的特征,并探索疾病活动的新型生物标志物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Implementation of optical coherence tomography in retinopathy of prematurity screening.

Purpose of review: In this review, we explore the investigational applications of optical coherence tomography (OCT) in retinopathy of prematurity (ROP), the insights they have delivered thus far, and key milestones for its integration into the standard of care.

Recent findings: While OCT has been widely integrated into clinical management of common retinal diseases, its use in pediatric contexts has been undermined by limitations in ergonomics, image acquisition time, and field of view. Recently, investigational handheld OCT devices have been reported with advancements including ultra-widefield view, noncontact use, and high-speed image capture permitting real-time en face visualization. These developments are compelling for OCT as a more objective alternative with reduced neonatal stress compared to indirect ophthalmoscopy and/or fundus photography as a means of classifying and monitoring ROP.

Summary: OCT may become a viable modality in management of ROP. Ongoing innovation surrounding handheld devices should aim to optimize patient comfort and image resolution in the retinal periphery. Future clinical investigations may seek to objectively characterize features of peripheral stage and explore novel biomarkers of disease activity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.80
自引率
5.40%
发文量
120
审稿时长
6-12 weeks
期刊介绍: Current Opinion in Ophthalmology is an indispensable resource featuring key up-to-date and important advances in the field from around the world. With renowned guest editors for each section, every bimonthly issue of Current Opinion in Ophthalmology delivers a fresh insight into topics such as glaucoma, refractive surgery and corneal and external disorders. With ten sections in total, the journal provides a convenient and thorough review of the field and will be of interest to researchers, clinicians and other healthcare professionals alike.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信