Nguyen Nguyen Truong, Nguyen Thi Minh Diep, Vu Anh Tuan
{"title":"利用双通道荧光检测器高效液相色谱法测定尿液中的诺氟沙星、环丙沙星、左氧氟沙星和莫西沙星","authors":"Nguyen Nguyen Truong, Nguyen Thi Minh Diep, Vu Anh Tuan","doi":"10.55401/jst.v6i4.2421","DOIUrl":null,"url":null,"abstract":"A sensitive HPLC-FLD method with two-channel fluorescence detection was established and validated for quantification of four fluoroquinolones (norfloxacin, ciprofloxacin, levofloxacin and moxifloxacin) in urine samples. The fluorescent detector was set at two-channel excitation and emission wavelengths: 280/445 nm (for NOR, CIP) and 290/500 nm (for LEVO, MOXI). The measurement protocol was in compatible with both of the sample treatment procedures including the liquid-liquid extraction (LLE) and solid-phase extraction (SPE). The method was well-validated with the limit of quantification: 0.027; 0.034; 0.024; 0.020 µg/mL (for LLE), and 0.028; 0.033; 0.024; 0.020 µg/mL (for SPE) for NOR, CIP, LEVO, MOXI, respectively. The method has been proved to be precise and accurate, with the relative standard deviation lower than 3% and the recovery ranging from 98.0%¸102.0%, for all fluoroquinolones. The proposed HPLC-FLD method provides an alternative approach for the simultaneous analysis of fluoroquinolones in urine. \n® 2023 Journal of Science and Technology - NTTU","PeriodicalId":17073,"journal":{"name":"Journal of Science and Technology","volume":"27 11","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of norfloxacin, cipfloxacin, levofloxacin and moxifloxacin in urine by HPLC with a two-channel fluorescence detector\",\"authors\":\"Nguyen Nguyen Truong, Nguyen Thi Minh Diep, Vu Anh Tuan\",\"doi\":\"10.55401/jst.v6i4.2421\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A sensitive HPLC-FLD method with two-channel fluorescence detection was established and validated for quantification of four fluoroquinolones (norfloxacin, ciprofloxacin, levofloxacin and moxifloxacin) in urine samples. The fluorescent detector was set at two-channel excitation and emission wavelengths: 280/445 nm (for NOR, CIP) and 290/500 nm (for LEVO, MOXI). The measurement protocol was in compatible with both of the sample treatment procedures including the liquid-liquid extraction (LLE) and solid-phase extraction (SPE). The method was well-validated with the limit of quantification: 0.027; 0.034; 0.024; 0.020 µg/mL (for LLE), and 0.028; 0.033; 0.024; 0.020 µg/mL (for SPE) for NOR, CIP, LEVO, MOXI, respectively. The method has been proved to be precise and accurate, with the relative standard deviation lower than 3% and the recovery ranging from 98.0%¸102.0%, for all fluoroquinolones. The proposed HPLC-FLD method provides an alternative approach for the simultaneous analysis of fluoroquinolones in urine. \\n® 2023 Journal of Science and Technology - NTTU\",\"PeriodicalId\":17073,\"journal\":{\"name\":\"Journal of Science and Technology\",\"volume\":\"27 11\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55401/jst.v6i4.2421\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55401/jst.v6i4.2421","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determination of norfloxacin, cipfloxacin, levofloxacin and moxifloxacin in urine by HPLC with a two-channel fluorescence detector
A sensitive HPLC-FLD method with two-channel fluorescence detection was established and validated for quantification of four fluoroquinolones (norfloxacin, ciprofloxacin, levofloxacin and moxifloxacin) in urine samples. The fluorescent detector was set at two-channel excitation and emission wavelengths: 280/445 nm (for NOR, CIP) and 290/500 nm (for LEVO, MOXI). The measurement protocol was in compatible with both of the sample treatment procedures including the liquid-liquid extraction (LLE) and solid-phase extraction (SPE). The method was well-validated with the limit of quantification: 0.027; 0.034; 0.024; 0.020 µg/mL (for LLE), and 0.028; 0.033; 0.024; 0.020 µg/mL (for SPE) for NOR, CIP, LEVO, MOXI, respectively. The method has been proved to be precise and accurate, with the relative standard deviation lower than 3% and the recovery ranging from 98.0%¸102.0%, for all fluoroquinolones. The proposed HPLC-FLD method provides an alternative approach for the simultaneous analysis of fluoroquinolones in urine.
® 2023 Journal of Science and Technology - NTTU