使用 Braincare® BCMM 2000 监测器对接受骨髓造影术的骨髓病犬的颅内压波形进行无创监测

N. L. Rocha, Guilherme S. Cardoso, Joel F. Nogueira, Mônica V. Bahr Arias
{"title":"使用 Braincare® BCMM 2000 监测器对接受骨髓造影术的骨髓病犬的颅内压波形进行无创监测","authors":"N. L. Rocha, Guilherme S. Cardoso, Joel F. Nogueira, Mônica V. Bahr Arias","doi":"10.1590/1678-5150-PVB-7132","DOIUrl":null,"url":null,"abstract":"ABSTRACT: Intracranial pressure (ICP) monitoring is considered the gold standard for optimizing the treatment of humans in intensive care units. However, this procedure is not commonly performed in veterinary medicine because of the limitations and complications of the method. There are some new promising non-invasive techniques for monitoring ICP, but they have not been validated in veterinary medicine. This study aimed to correlate the non-invasive intracranial pressure (NI-ICP) waveforms obtained with the BCMM-2000 Brain4care monitor during myelography in dogs with myelopathies undergoing this exam for diagnostic purposes with the waveforms obtained through invasive monitoring of the subarachnoid pressure (SP). The NI-ICP waveform was monitored in six dogs with myelopathies before (M1), during (M2), and after (M3) contrast medium injection into the subarachnoid space. Cerebrospinal fluid (CSF) was collected before contrast injection. The SP waveform was simultaneously monitored in three of the six dogs. Correlations between the two methods were performed using Pearson’s coefficient. The analysis of the morphology and amplitude of the waves at each moment was performed, and at M2, an increase in the P2:P1 ratio (p<0.05) was observed in both monitoring methods. In M3, the values were similar to those of M1, demonstrating the return of cerebral compliance. The comparison of the NI-ICP and SP had a positive correlation in those moments (Pearson’s coefficient r=0.76; p=0.027). The speed of contrast administration, degree of spinal cord compression, and volume of CSF previously collected may affect P2:P1 and ICP dynamics. The BCMM-2000 Brain4care monitor was effective in detecting changes in ICP dynamics and abnormal pulse waveforms in dogs with meningoencephalitis of unknown origin, vertebral neoplasm and intervertebral disc disease with and without hemorrhagic myelomalacia, suggesting increased ICP induced by myelography.","PeriodicalId":19995,"journal":{"name":"Pesquisa Veterinária Brasileira","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Non-invasive monitoring of intracranial pressure waveforms using Braincare® BCMM 2000 monitor in dogs with myelopathies undergoing myelography\",\"authors\":\"N. L. Rocha, Guilherme S. Cardoso, Joel F. Nogueira, Mônica V. Bahr Arias\",\"doi\":\"10.1590/1678-5150-PVB-7132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT: Intracranial pressure (ICP) monitoring is considered the gold standard for optimizing the treatment of humans in intensive care units. However, this procedure is not commonly performed in veterinary medicine because of the limitations and complications of the method. There are some new promising non-invasive techniques for monitoring ICP, but they have not been validated in veterinary medicine. This study aimed to correlate the non-invasive intracranial pressure (NI-ICP) waveforms obtained with the BCMM-2000 Brain4care monitor during myelography in dogs with myelopathies undergoing this exam for diagnostic purposes with the waveforms obtained through invasive monitoring of the subarachnoid pressure (SP). The NI-ICP waveform was monitored in six dogs with myelopathies before (M1), during (M2), and after (M3) contrast medium injection into the subarachnoid space. Cerebrospinal fluid (CSF) was collected before contrast injection. The SP waveform was simultaneously monitored in three of the six dogs. Correlations between the two methods were performed using Pearson’s coefficient. The analysis of the morphology and amplitude of the waves at each moment was performed, and at M2, an increase in the P2:P1 ratio (p<0.05) was observed in both monitoring methods. In M3, the values were similar to those of M1, demonstrating the return of cerebral compliance. The comparison of the NI-ICP and SP had a positive correlation in those moments (Pearson’s coefficient r=0.76; p=0.027). The speed of contrast administration, degree of spinal cord compression, and volume of CSF previously collected may affect P2:P1 and ICP dynamics. The BCMM-2000 Brain4care monitor was effective in detecting changes in ICP dynamics and abnormal pulse waveforms in dogs with meningoencephalitis of unknown origin, vertebral neoplasm and intervertebral disc disease with and without hemorrhagic myelomalacia, suggesting increased ICP induced by myelography.\",\"PeriodicalId\":19995,\"journal\":{\"name\":\"Pesquisa Veterinária Brasileira\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pesquisa Veterinária Brasileira\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/1678-5150-PVB-7132\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pesquisa Veterinária Brasileira","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1678-5150-PVB-7132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要:颅内压 (ICP) 监测被认为是重症监护室优化人类治疗的黄金标准。然而,由于该方法的局限性和并发症,在兽医领域并不常用。目前有一些新的无创技术可用于监测 ICP,但尚未在兽医学中得到验证。本研究的目的是在对患有骨髓病的犬进行骨髓造影诊断时,将使用 BCMM-2000 Brain4care 监护仪获得的无创颅内压 (NI-ICP) 波形与通过有创蛛网膜下腔压力 (SP) 监测获得的波形进行关联。在向蛛网膜下腔注射造影剂之前(M1)、期间(M2)和之后(M3),对六只患有骨髓病的狗进行了 NI-ICP 波形监测。注射造影剂前收集脑脊液(CSF)。六只狗中有三只同时监测了 SP 波形。使用皮尔逊系数对两种方法进行相关性分析。在 M2 阶段,两种监测方法都观察到 P2:P1 比值增加(p<0.05)。在 M3,数值与 M1 相似,表明大脑顺应性恢复。在这些时刻,NI-ICP 和 SP 的比较呈正相关(皮尔逊系数 r=0.76;p=0.027)。造影剂给药速度、脊髓压迫程度和之前收集的 CSF 量可能会影响 P2:P1 和 ICP 动态。BCMM-2000 Brain4care 监测器能有效检测出不明原因脑膜脑炎、椎体肿瘤和椎间盘疾病(伴有或不伴有出血性脊髓空洞症)犬的 ICP 动态变化和异常脉搏波形,这表明脊髓造影会诱发 ICP 增高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Non-invasive monitoring of intracranial pressure waveforms using Braincare® BCMM 2000 monitor in dogs with myelopathies undergoing myelography
ABSTRACT: Intracranial pressure (ICP) monitoring is considered the gold standard for optimizing the treatment of humans in intensive care units. However, this procedure is not commonly performed in veterinary medicine because of the limitations and complications of the method. There are some new promising non-invasive techniques for monitoring ICP, but they have not been validated in veterinary medicine. This study aimed to correlate the non-invasive intracranial pressure (NI-ICP) waveforms obtained with the BCMM-2000 Brain4care monitor during myelography in dogs with myelopathies undergoing this exam for diagnostic purposes with the waveforms obtained through invasive monitoring of the subarachnoid pressure (SP). The NI-ICP waveform was monitored in six dogs with myelopathies before (M1), during (M2), and after (M3) contrast medium injection into the subarachnoid space. Cerebrospinal fluid (CSF) was collected before contrast injection. The SP waveform was simultaneously monitored in three of the six dogs. Correlations between the two methods were performed using Pearson’s coefficient. The analysis of the morphology and amplitude of the waves at each moment was performed, and at M2, an increase in the P2:P1 ratio (p<0.05) was observed in both monitoring methods. In M3, the values were similar to those of M1, demonstrating the return of cerebral compliance. The comparison of the NI-ICP and SP had a positive correlation in those moments (Pearson’s coefficient r=0.76; p=0.027). The speed of contrast administration, degree of spinal cord compression, and volume of CSF previously collected may affect P2:P1 and ICP dynamics. The BCMM-2000 Brain4care monitor was effective in detecting changes in ICP dynamics and abnormal pulse waveforms in dogs with meningoencephalitis of unknown origin, vertebral neoplasm and intervertebral disc disease with and without hemorrhagic myelomalacia, suggesting increased ICP induced by myelography.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信