{"title":"热障对棒材 Jominy 中马氏体转变的影响","authors":"D. Rezini, Touhami Baki","doi":"10.2478/scjme-2023-0028","DOIUrl":null,"url":null,"abstract":"Abstract The shape and geometry of a part influence the cooling behavior during a martensitic transformation; an experimental study carried out on a control Jominy bar was compared with other bars fitted with one, two, and three slots; the results show differences in hardness along the specimen, the hardness with a slit and more is greater than the hardness on a sample without a slit, this is valid on the cooled side of the specimen, the further away from the side cooled plus the difference is minimal; the study was completed with a simulation on bars with and without slits, the results of the temperature contours show an acceleration of the cooling on the cooled side of the bars provided with slits; far from the cooled face the influence of the slits is weak.","PeriodicalId":445896,"journal":{"name":"Strojnícky časopis - Journal of Mechanical Engineering","volume":"104 1","pages":"133 - 144"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Thermal Barriers on the Martensitic Transformation in a Bar Jominy\",\"authors\":\"D. Rezini, Touhami Baki\",\"doi\":\"10.2478/scjme-2023-0028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The shape and geometry of a part influence the cooling behavior during a martensitic transformation; an experimental study carried out on a control Jominy bar was compared with other bars fitted with one, two, and three slots; the results show differences in hardness along the specimen, the hardness with a slit and more is greater than the hardness on a sample without a slit, this is valid on the cooled side of the specimen, the further away from the side cooled plus the difference is minimal; the study was completed with a simulation on bars with and without slits, the results of the temperature contours show an acceleration of the cooling on the cooled side of the bars provided with slits; far from the cooled face the influence of the slits is weak.\",\"PeriodicalId\":445896,\"journal\":{\"name\":\"Strojnícky časopis - Journal of Mechanical Engineering\",\"volume\":\"104 1\",\"pages\":\"133 - 144\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Strojnícky časopis - Journal of Mechanical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/scjme-2023-0028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strojnícky časopis - Journal of Mechanical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/scjme-2023-0028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of Thermal Barriers on the Martensitic Transformation in a Bar Jominy
Abstract The shape and geometry of a part influence the cooling behavior during a martensitic transformation; an experimental study carried out on a control Jominy bar was compared with other bars fitted with one, two, and three slots; the results show differences in hardness along the specimen, the hardness with a slit and more is greater than the hardness on a sample without a slit, this is valid on the cooled side of the specimen, the further away from the side cooled plus the difference is minimal; the study was completed with a simulation on bars with and without slits, the results of the temperature contours show an acceleration of the cooling on the cooled side of the bars provided with slits; far from the cooled face the influence of the slits is weak.