{"title":"用停止时间研究法确定标准时间 Syam 水库案例研究","authors":"Asri Nurhasanah, Bratama Ibramgara, Taufik Hidayaturrahman","doi":"10.31949/stima.v7i0.1023","DOIUrl":null,"url":null,"abstract":"Depot Air Syam is a service company that produces mineral water. However, often these targets cannot be met, so companies consider whether to revise for those company targets. In order for the company to continue to survive and win the increasingly fierce competition, it needs these advantages in addition to being obtained through increased productivity. One of the ways that companies do is by measuring standard time. The purpose of this study is to help companies to consider the need for revision of company targets. The observation method is the method used in this study, resulting in a standard time in the gallon water refilling process of 241.4 seconds. This time is obtained from the average cycle time of 164.4 seconds.","PeriodicalId":161203,"journal":{"name":"SEMINAR TEKNOLOGI MAJALENGKA (STIMA)","volume":"4 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Penentuan Waktu Baku dengan Metode Stopwacth Time Study Studi Kasus Depot Air Syam\",\"authors\":\"Asri Nurhasanah, Bratama Ibramgara, Taufik Hidayaturrahman\",\"doi\":\"10.31949/stima.v7i0.1023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Depot Air Syam is a service company that produces mineral water. However, often these targets cannot be met, so companies consider whether to revise for those company targets. In order for the company to continue to survive and win the increasingly fierce competition, it needs these advantages in addition to being obtained through increased productivity. One of the ways that companies do is by measuring standard time. The purpose of this study is to help companies to consider the need for revision of company targets. The observation method is the method used in this study, resulting in a standard time in the gallon water refilling process of 241.4 seconds. This time is obtained from the average cycle time of 164.4 seconds.\",\"PeriodicalId\":161203,\"journal\":{\"name\":\"SEMINAR TEKNOLOGI MAJALENGKA (STIMA)\",\"volume\":\"4 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SEMINAR TEKNOLOGI MAJALENGKA (STIMA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31949/stima.v7i0.1023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEMINAR TEKNOLOGI MAJALENGKA (STIMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31949/stima.v7i0.1023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
Depot Air Syam 是一家生产矿泉水的服务公司。然而,这些目标往往无法实现,因此公司要考虑是否对这些公司目标进行修订。为了让公司继续生存下去,并在日益激烈的竞争中获胜,除了通过提高生产率获得优势外,公司还需要这些优势。公司的方法之一就是测量标准时间。本研究的目的是帮助公司考虑修订公司目标的必要性。本研究采用观察法,得出加仑水加注过程的标准时间为 241.4 秒。这个时间是从 164.4 秒的平均周期时间中得出的。
Penentuan Waktu Baku dengan Metode Stopwacth Time Study Studi Kasus Depot Air Syam
Depot Air Syam is a service company that produces mineral water. However, often these targets cannot be met, so companies consider whether to revise for those company targets. In order for the company to continue to survive and win the increasingly fierce competition, it needs these advantages in addition to being obtained through increased productivity. One of the ways that companies do is by measuring standard time. The purpose of this study is to help companies to consider the need for revision of company targets. The observation method is the method used in this study, resulting in a standard time in the gallon water refilling process of 241.4 seconds. This time is obtained from the average cycle time of 164.4 seconds.