开发了三平面磁共振骨盆测量法。

E. D. Vyshedkevich, S. R. Sheriev, I. S. Paleeva, I. Mashchenko, A. Y. Efimtsev
{"title":"开发了三平面磁共振骨盆测量法。","authors":"E. D. Vyshedkevich, S. R. Sheriev, I. S. Paleeva, I. Mashchenko, A. Y. Efimtsev","doi":"10.18705/2311-4495-2023-10-5-455-465","DOIUrl":null,"url":null,"abstract":"Background. Magnetic resonance pelviophetometry is a highly informative, non-invasive and safe method for assessing the size of the pelvis of a pregnant woman and the fetal head, but it has several disadvantages — a long scanning time, heating of the tissues of the pregnant woman and the fetus, and operator dependence.Objective. Evaluation of the capabilities of the three-plane 3D Dixon MR-pelviophetometry (3D MR-PFM) technique, its comparative analysis with the generally accepted method of two-plane 2D MR-pelviophetometry (2D MR-PFM).Design and methods. A retrospective analysis was perormed out in 26 pregnant women with risk for the development clinically narrow pelvis for various reasons. Results. The data obtained using the Dixon pulse sequence is comparable to the data obtained during the standard technique.Conclusion. The Dixon sequence can be used for the developed 3D method of MR pelviophetometry, since it allows to reduce the scanning time and, according to statistical analysis, show comparable results.","PeriodicalId":23243,"journal":{"name":"Translational Medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Developed method of three-plane magnetic resonance pelviophetometry.\",\"authors\":\"E. D. Vyshedkevich, S. R. Sheriev, I. S. Paleeva, I. Mashchenko, A. Y. Efimtsev\",\"doi\":\"10.18705/2311-4495-2023-10-5-455-465\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background. Magnetic resonance pelviophetometry is a highly informative, non-invasive and safe method for assessing the size of the pelvis of a pregnant woman and the fetal head, but it has several disadvantages — a long scanning time, heating of the tissues of the pregnant woman and the fetus, and operator dependence.Objective. Evaluation of the capabilities of the three-plane 3D Dixon MR-pelviophetometry (3D MR-PFM) technique, its comparative analysis with the generally accepted method of two-plane 2D MR-pelviophetometry (2D MR-PFM).Design and methods. A retrospective analysis was perormed out in 26 pregnant women with risk for the development clinically narrow pelvis for various reasons. Results. The data obtained using the Dixon pulse sequence is comparable to the data obtained during the standard technique.Conclusion. The Dixon sequence can be used for the developed 3D method of MR pelviophetometry, since it allows to reduce the scanning time and, according to statistical analysis, show comparable results.\",\"PeriodicalId\":23243,\"journal\":{\"name\":\"Translational Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Translational Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18705/2311-4495-2023-10-5-455-465\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Translational Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18705/2311-4495-2023-10-5-455-465","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景。磁共振骨盆测量法是一种信息量大、无创、安全的评估孕妇骨盆和胎儿头部大小的方法,但它有几个缺点--扫描时间长、孕妇和胎儿的组织会发热以及对操作者的依赖性。评估三平面三维 Dixon MR-Pelviophetometry(三维 MR-PFM)技术的能力,并将其与公认的两平面二维 MR-pelviophetometry (二维 MR-PFM)方法进行比较分析。对 26 名因各种原因导致临床骨盆狭窄的孕妇进行了回顾性分析。结果使用 Dixon 脉冲序列获得的数据与标准技术获得的数据相当。迪克森序列可用于已开发的三维磁共振骨盆测量方法,因为它可以缩短扫描时间,而且根据统计分析,显示的结果具有可比性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Developed method of three-plane magnetic resonance pelviophetometry.
Background. Magnetic resonance pelviophetometry is a highly informative, non-invasive and safe method for assessing the size of the pelvis of a pregnant woman and the fetal head, but it has several disadvantages — a long scanning time, heating of the tissues of the pregnant woman and the fetus, and operator dependence.Objective. Evaluation of the capabilities of the three-plane 3D Dixon MR-pelviophetometry (3D MR-PFM) technique, its comparative analysis with the generally accepted method of two-plane 2D MR-pelviophetometry (2D MR-PFM).Design and methods. A retrospective analysis was perormed out in 26 pregnant women with risk for the development clinically narrow pelvis for various reasons. Results. The data obtained using the Dixon pulse sequence is comparable to the data obtained during the standard technique.Conclusion. The Dixon sequence can be used for the developed 3D method of MR pelviophetometry, since it allows to reduce the scanning time and, according to statistical analysis, show comparable results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信