{"title":"宜兴水泵-涡轮机头盖螺栓的力特性分析","authors":"Xiang Zhou, Delou Wang, Peng Zhang, Liu Chen, Zheng Zhang, Chengjun Li, Yuwen Chen, Shunyi Chen, Tianjiao Xue","doi":"10.62051/q455cv40","DOIUrl":null,"url":null,"abstract":"This article conducts numerical calculations on the head cover bolts of the pump turbine in Yixing Pumped Storage Power Station under typical steady-state and transient conditions and analyses the force characteristics of the coupling bolts under turbine, pump, pump zero flow and load rejection conditions. On this basis, further evaluation of head cover bolts safety and reasonable suggestions for subsequent operation are provided.","PeriodicalId":503289,"journal":{"name":"Transactions on Engineering and Technology Research","volume":"79 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Force Characteristics Analysis of Yixing Pump-Turbine Head Cover Bolts\",\"authors\":\"Xiang Zhou, Delou Wang, Peng Zhang, Liu Chen, Zheng Zhang, Chengjun Li, Yuwen Chen, Shunyi Chen, Tianjiao Xue\",\"doi\":\"10.62051/q455cv40\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article conducts numerical calculations on the head cover bolts of the pump turbine in Yixing Pumped Storage Power Station under typical steady-state and transient conditions and analyses the force characteristics of the coupling bolts under turbine, pump, pump zero flow and load rejection conditions. On this basis, further evaluation of head cover bolts safety and reasonable suggestions for subsequent operation are provided.\",\"PeriodicalId\":503289,\"journal\":{\"name\":\"Transactions on Engineering and Technology Research\",\"volume\":\"79 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions on Engineering and Technology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.62051/q455cv40\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions on Engineering and Technology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.62051/q455cv40","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Force Characteristics Analysis of Yixing Pump-Turbine Head Cover Bolts
This article conducts numerical calculations on the head cover bolts of the pump turbine in Yixing Pumped Storage Power Station under typical steady-state and transient conditions and analyses the force characteristics of the coupling bolts under turbine, pump, pump zero flow and load rejection conditions. On this basis, further evaluation of head cover bolts safety and reasonable suggestions for subsequent operation are provided.