研究流量对淋浴疗法中 DS18B20 传感器水温读数的影响

Eko Arianto
{"title":"研究流量对淋浴疗法中 DS18B20 传感器水温读数的影响","authors":"Eko Arianto","doi":"10.35134/jitekin.v13i2.100","DOIUrl":null,"url":null,"abstract":"The shifting lifestyle trends towards prolonged periods of sitting have led to an increase in health issues such as stress, depression, and even hypertension. In the pursuit of maintaining health, therapy, particularly shower therapy, has become a popular choice for its perceived ability to provide warmth, relaxation, and alleviate fatigue. However, questions arise regarding whether the water temperature in shower therapy changes as water flows at specific rates and how this might influence the therapy's effectiveness. This research aims to observe whether the water temperature in shower therapy is affected by the flow rate using the DS18B20 temperature sensor. The method involves measuring the water temperature at rest and while it flows at various flow rates. Water flow is controlled using a dimmer on the booster pump, while temperature measurements are taken using the DS18B20 temperature sensor and water flow meter sensor. The test results indicate that water at temperatures of 38-43°C flowing through pipes experiences an average temperature decrease of approximately 1.53°C. However, the temperature decrease does not exhibit a linear relationship with the flow rate. These findings suggest the possibility of other factors, such as the surface area of the conduit (pipes), influencing the temperature reduction in shower therapy. Hence, further research to examine the impact of the surface area of the conduit on the temperature reduction in shower therapy is warranted to obtain a more comprehensive understanding.","PeriodicalId":55763,"journal":{"name":"Jurnal Teknologi","volume":" 33","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigasi Pengaruh Flow terhadap Pembacaan Suhu Air Sensor DS18B20 pada Shower Therapy\",\"authors\":\"Eko Arianto\",\"doi\":\"10.35134/jitekin.v13i2.100\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The shifting lifestyle trends towards prolonged periods of sitting have led to an increase in health issues such as stress, depression, and even hypertension. In the pursuit of maintaining health, therapy, particularly shower therapy, has become a popular choice for its perceived ability to provide warmth, relaxation, and alleviate fatigue. However, questions arise regarding whether the water temperature in shower therapy changes as water flows at specific rates and how this might influence the therapy's effectiveness. This research aims to observe whether the water temperature in shower therapy is affected by the flow rate using the DS18B20 temperature sensor. The method involves measuring the water temperature at rest and while it flows at various flow rates. Water flow is controlled using a dimmer on the booster pump, while temperature measurements are taken using the DS18B20 temperature sensor and water flow meter sensor. The test results indicate that water at temperatures of 38-43°C flowing through pipes experiences an average temperature decrease of approximately 1.53°C. However, the temperature decrease does not exhibit a linear relationship with the flow rate. These findings suggest the possibility of other factors, such as the surface area of the conduit (pipes), influencing the temperature reduction in shower therapy. Hence, further research to examine the impact of the surface area of the conduit on the temperature reduction in shower therapy is warranted to obtain a more comprehensive understanding.\",\"PeriodicalId\":55763,\"journal\":{\"name\":\"Jurnal Teknologi\",\"volume\":\" 33\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Teknologi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35134/jitekin.v13i2.100\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknologi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35134/jitekin.v13i2.100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

长时间坐着的生活方式的改变导致压力、抑郁甚至高血压等健康问题的增加。在追求健康的过程中,理疗,尤其是淋浴理疗,因其能够提供温暖、放松和缓解疲劳而成为一种流行的选择。然而,淋浴疗法中的水温是否会随着特定流速的水流而发生变化,以及这会如何影响疗法的效果,这些都是问题所在。本研究旨在使用 DS18B20 温度传感器观察淋浴疗法中的水温是否受流速影响。该方法包括测量静止时的水温和以不同流速流动时的水温。使用增压泵上的调光器控制水流,同时使用 DS18B20 温度传感器和水流量计传感器测量温度。测试结果表明,温度为 38-43°C 的水流过管道时,平均温度下降了约 1.53°C。然而,温度下降与流速并不呈线性关系。这些结果表明,可能还有其他因素(如导管(管道)的表面积)会影响淋浴疗法中的温度降低。因此,有必要进一步研究导管表面积对淋浴疗法中温度降低的影响,以获得更全面的认识。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigasi Pengaruh Flow terhadap Pembacaan Suhu Air Sensor DS18B20 pada Shower Therapy
The shifting lifestyle trends towards prolonged periods of sitting have led to an increase in health issues such as stress, depression, and even hypertension. In the pursuit of maintaining health, therapy, particularly shower therapy, has become a popular choice for its perceived ability to provide warmth, relaxation, and alleviate fatigue. However, questions arise regarding whether the water temperature in shower therapy changes as water flows at specific rates and how this might influence the therapy's effectiveness. This research aims to observe whether the water temperature in shower therapy is affected by the flow rate using the DS18B20 temperature sensor. The method involves measuring the water temperature at rest and while it flows at various flow rates. Water flow is controlled using a dimmer on the booster pump, while temperature measurements are taken using the DS18B20 temperature sensor and water flow meter sensor. The test results indicate that water at temperatures of 38-43°C flowing through pipes experiences an average temperature decrease of approximately 1.53°C. However, the temperature decrease does not exhibit a linear relationship with the flow rate. These findings suggest the possibility of other factors, such as the surface area of the conduit (pipes), influencing the temperature reduction in shower therapy. Hence, further research to examine the impact of the surface area of the conduit on the temperature reduction in shower therapy is warranted to obtain a more comprehensive understanding.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信