Fernanda B Martins, Millena B Oliveira, Leandro M Oliveira, Alan Grupioni Lourenço, Luiz Renato Paranhos, Ana Carolina F Motta
{"title":"与唾液腺活检相关的超声波检查对斯约戈伦综合征的诊断准确性:系统回顾与荟萃分析。","authors":"Fernanda B Martins, Millena B Oliveira, Leandro M Oliveira, Alan Grupioni Lourenço, Luiz Renato Paranhos, Ana Carolina F Motta","doi":"10.1093/dmfr/twad007","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the accuracy of major salivary gland ultrasonography (SGUS) in relation to minor salivary gland biopsy (mSGB) in the diagnosis of Sjögren's syndrome (SS).</p><p><strong>Methods: </strong>A systematic review and meta-analysis were performed. Ten databases were searched to identify studies that compared the accuracy of SGUS and mSGB. The risk of bias was assessed, data were extracted, and univariate and bivariate random-effects meta-analyses were done.</p><p><strong>Results: </strong>A total of 5000 records were identified; 13 studies were included in the qualitative synthesis and 10 in the quantitative synthesis. The first meta-analysis found a sensitivity of 0.86 (95% CI: 0.74-0.92) and specificity of 0.87 (95% CI: 0.81-0.92) for the predictive value of SGUS scoring in relation to the result of mSGB. In the second meta-analysis, mSGB showed higher sensitivity and specificity than SGUS. Sensitivity was 0.80 (95% CI: 0.74-0.85) for mSGB and 0.71 (95% CI: 0.58-0.81) for SGUS, and specificity was 0.94 (95% CI: 0.87-0.97) for mSGB and 0.89 (95% CI: 0.82-0.94) for SGUS.</p><p><strong>Conclusions: </strong>The diagnostic accuracy of SGUS was similar to that of mSGB. SGUS is an effective diagnostic test that shows good sensitivity and high specificity, in addition to being a good tool for prognosis and for avoiding unnecessary biopsies. More studies using similar methodologies are needed to assess the accuracy of SGUS in predicting the result of mSGB. Our results will contribute to decision-making for the implementation of SGUS as a diagnostic tool for SS, considering the advantages of this method.</p>","PeriodicalId":11261,"journal":{"name":"Dento maxillo facial radiology","volume":" ","pages":"91-102"},"PeriodicalIF":2.9000,"publicationDate":"2024-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic accuracy of ultrasonography in relation to salivary gland biopsy in Sjögren's syndrome: a systematic review with meta-analysis.\",\"authors\":\"Fernanda B Martins, Millena B Oliveira, Leandro M Oliveira, Alan Grupioni Lourenço, Luiz Renato Paranhos, Ana Carolina F Motta\",\"doi\":\"10.1093/dmfr/twad007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate the accuracy of major salivary gland ultrasonography (SGUS) in relation to minor salivary gland biopsy (mSGB) in the diagnosis of Sjögren's syndrome (SS).</p><p><strong>Methods: </strong>A systematic review and meta-analysis were performed. Ten databases were searched to identify studies that compared the accuracy of SGUS and mSGB. The risk of bias was assessed, data were extracted, and univariate and bivariate random-effects meta-analyses were done.</p><p><strong>Results: </strong>A total of 5000 records were identified; 13 studies were included in the qualitative synthesis and 10 in the quantitative synthesis. The first meta-analysis found a sensitivity of 0.86 (95% CI: 0.74-0.92) and specificity of 0.87 (95% CI: 0.81-0.92) for the predictive value of SGUS scoring in relation to the result of mSGB. In the second meta-analysis, mSGB showed higher sensitivity and specificity than SGUS. Sensitivity was 0.80 (95% CI: 0.74-0.85) for mSGB and 0.71 (95% CI: 0.58-0.81) for SGUS, and specificity was 0.94 (95% CI: 0.87-0.97) for mSGB and 0.89 (95% CI: 0.82-0.94) for SGUS.</p><p><strong>Conclusions: </strong>The diagnostic accuracy of SGUS was similar to that of mSGB. SGUS is an effective diagnostic test that shows good sensitivity and high specificity, in addition to being a good tool for prognosis and for avoiding unnecessary biopsies. More studies using similar methodologies are needed to assess the accuracy of SGUS in predicting the result of mSGB. Our results will contribute to decision-making for the implementation of SGUS as a diagnostic tool for SS, considering the advantages of this method.</p>\",\"PeriodicalId\":11261,\"journal\":{\"name\":\"Dento maxillo facial radiology\",\"volume\":\" \",\"pages\":\"91-102\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-02-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dento maxillo facial radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/dmfr/twad007\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dento maxillo facial radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/dmfr/twad007","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Diagnostic accuracy of ultrasonography in relation to salivary gland biopsy in Sjögren's syndrome: a systematic review with meta-analysis.
Objectives: To evaluate the accuracy of major salivary gland ultrasonography (SGUS) in relation to minor salivary gland biopsy (mSGB) in the diagnosis of Sjögren's syndrome (SS).
Methods: A systematic review and meta-analysis were performed. Ten databases were searched to identify studies that compared the accuracy of SGUS and mSGB. The risk of bias was assessed, data were extracted, and univariate and bivariate random-effects meta-analyses were done.
Results: A total of 5000 records were identified; 13 studies were included in the qualitative synthesis and 10 in the quantitative synthesis. The first meta-analysis found a sensitivity of 0.86 (95% CI: 0.74-0.92) and specificity of 0.87 (95% CI: 0.81-0.92) for the predictive value of SGUS scoring in relation to the result of mSGB. In the second meta-analysis, mSGB showed higher sensitivity and specificity than SGUS. Sensitivity was 0.80 (95% CI: 0.74-0.85) for mSGB and 0.71 (95% CI: 0.58-0.81) for SGUS, and specificity was 0.94 (95% CI: 0.87-0.97) for mSGB and 0.89 (95% CI: 0.82-0.94) for SGUS.
Conclusions: The diagnostic accuracy of SGUS was similar to that of mSGB. SGUS is an effective diagnostic test that shows good sensitivity and high specificity, in addition to being a good tool for prognosis and for avoiding unnecessary biopsies. More studies using similar methodologies are needed to assess the accuracy of SGUS in predicting the result of mSGB. Our results will contribute to decision-making for the implementation of SGUS as a diagnostic tool for SS, considering the advantages of this method.
期刊介绍:
Dentomaxillofacial Radiology (DMFR) is the journal of the International Association of Dentomaxillofacial Radiology (IADMFR) and covers the closely related fields of oral radiology and head and neck imaging.
Established in 1972, DMFR is a key resource keeping dentists, radiologists and clinicians and scientists with an interest in Head and Neck imaging abreast of important research and developments in oral and maxillofacial radiology.
The DMFR editorial board features a panel of international experts including Editor-in-Chief Professor Ralf Schulze. Our editorial board provide their expertise and guidance in shaping the content and direction of the journal.
Quick Facts:
- 2015 Impact Factor - 1.919
- Receipt to first decision - average of 3 weeks
- Acceptance to online publication - average of 3 weeks
- Open access option
- ISSN: 0250-832X
- eISSN: 1476-542X