Pelin Kiyat, Timur Kose, Banu Gümüstas, Ozlem Barut Selver
{"title":"评估糖尿病神经病变患者的角膜敏感性和正交变异性。","authors":"Pelin Kiyat, Timur Kose, Banu Gümüstas, Ozlem Barut Selver","doi":"10.4103/meajo.meajo_111_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of the study was to evaluate the corneal sensitivity and its quadrature variability in patients with diabetic neuropathy (DN) diagnosed with electromyography and to compare these results with age- and sex-matched healthy individuals.</p><p><strong>Methods: </strong>The left eyes of 32 patients who applied for refraction or fundus examination and had a diagnosis of DN by electromyography in their medical history were included in this study. Corneal sensitivity was evaluated using the Cochet-Bonnet esthesiometer (Luneau, Paris) in five zones: central, nasal, superior, temporal, and inferior. The measurements of the patients were compared with the measurements of 32 age- and sex-matched healthy volunteers. Furthermore, the measurements of five corneal zones were compared with each other, and the level of correlation was investigated in each group.</p><p><strong>Results: </strong>The central corneal sensitivity values were measured as 4.12 ± 1.04 (mm) and 5.92 ± 0.14 (mm) (<i>P</i> < 0.001). While the sensitivity values at the superior, inferior, nasal, and temporal quadrants were detected as 5.85 ± 0.21, 5.85 ± 0.26, 5.94 ± 0.13, 5.93 ± 0.13, and 5.92 ± 0.14 (mm) in the control group, it was measured as 3.67 ± 0.66, 3.67 ± 0.62, 3.67 ± 0.62, and 3.89 ± 0.73 (mm) in the DN group, respectively. The corneal sensitivity values were all found to be significantly lower in the DN group (<i>P</i> < 0.001 for all parameters) at all quadrants as well as the central cornea. Furthermore, a moderate positive correlation between all five zones in the control group and a very strong positive correlation in the DN group were found in terms of the corneal quadrature sensitivity.</p><p><strong>Conclusion: </strong>The current study revealed a significant reduction in corneal sensitivity in patients with DN. In both the control group and DN group, all corneal zones showed positive correlations which show the consistency of the measurement in different quadratures. Evaluating corneal sensitivity with a Cochet-Bonnet esthesiometer might serve as a useful screening tool in detecting neuropathy development. By taking the necessary precautions, further damage can be prevented.</p>","PeriodicalId":18740,"journal":{"name":"Middle East African Journal of Ophthalmology","volume":"29 4","pages":"200-204"},"PeriodicalIF":0.5000,"publicationDate":"2023-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10754107/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Corneal Sensitivity and Quadrature Variability in Patients with Diabetic Neuropathy.\",\"authors\":\"Pelin Kiyat, Timur Kose, Banu Gümüstas, Ozlem Barut Selver\",\"doi\":\"10.4103/meajo.meajo_111_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of the study was to evaluate the corneal sensitivity and its quadrature variability in patients with diabetic neuropathy (DN) diagnosed with electromyography and to compare these results with age- and sex-matched healthy individuals.</p><p><strong>Methods: </strong>The left eyes of 32 patients who applied for refraction or fundus examination and had a diagnosis of DN by electromyography in their medical history were included in this study. Corneal sensitivity was evaluated using the Cochet-Bonnet esthesiometer (Luneau, Paris) in five zones: central, nasal, superior, temporal, and inferior. The measurements of the patients were compared with the measurements of 32 age- and sex-matched healthy volunteers. Furthermore, the measurements of five corneal zones were compared with each other, and the level of correlation was investigated in each group.</p><p><strong>Results: </strong>The central corneal sensitivity values were measured as 4.12 ± 1.04 (mm) and 5.92 ± 0.14 (mm) (<i>P</i> < 0.001). While the sensitivity values at the superior, inferior, nasal, and temporal quadrants were detected as 5.85 ± 0.21, 5.85 ± 0.26, 5.94 ± 0.13, 5.93 ± 0.13, and 5.92 ± 0.14 (mm) in the control group, it was measured as 3.67 ± 0.66, 3.67 ± 0.62, 3.67 ± 0.62, and 3.89 ± 0.73 (mm) in the DN group, respectively. The corneal sensitivity values were all found to be significantly lower in the DN group (<i>P</i> < 0.001 for all parameters) at all quadrants as well as the central cornea. Furthermore, a moderate positive correlation between all five zones in the control group and a very strong positive correlation in the DN group were found in terms of the corneal quadrature sensitivity.</p><p><strong>Conclusion: </strong>The current study revealed a significant reduction in corneal sensitivity in patients with DN. In both the control group and DN group, all corneal zones showed positive correlations which show the consistency of the measurement in different quadratures. Evaluating corneal sensitivity with a Cochet-Bonnet esthesiometer might serve as a useful screening tool in detecting neuropathy development. By taking the necessary precautions, further damage can be prevented.</p>\",\"PeriodicalId\":18740,\"journal\":{\"name\":\"Middle East African Journal of Ophthalmology\",\"volume\":\"29 4\",\"pages\":\"200-204\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10754107/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Middle East African Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/meajo.meajo_111_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/10/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Middle East African Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/meajo.meajo_111_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Evaluation of Corneal Sensitivity and Quadrature Variability in Patients with Diabetic Neuropathy.
Purpose: The purpose of the study was to evaluate the corneal sensitivity and its quadrature variability in patients with diabetic neuropathy (DN) diagnosed with electromyography and to compare these results with age- and sex-matched healthy individuals.
Methods: The left eyes of 32 patients who applied for refraction or fundus examination and had a diagnosis of DN by electromyography in their medical history were included in this study. Corneal sensitivity was evaluated using the Cochet-Bonnet esthesiometer (Luneau, Paris) in five zones: central, nasal, superior, temporal, and inferior. The measurements of the patients were compared with the measurements of 32 age- and sex-matched healthy volunteers. Furthermore, the measurements of five corneal zones were compared with each other, and the level of correlation was investigated in each group.
Results: The central corneal sensitivity values were measured as 4.12 ± 1.04 (mm) and 5.92 ± 0.14 (mm) (P < 0.001). While the sensitivity values at the superior, inferior, nasal, and temporal quadrants were detected as 5.85 ± 0.21, 5.85 ± 0.26, 5.94 ± 0.13, 5.93 ± 0.13, and 5.92 ± 0.14 (mm) in the control group, it was measured as 3.67 ± 0.66, 3.67 ± 0.62, 3.67 ± 0.62, and 3.89 ± 0.73 (mm) in the DN group, respectively. The corneal sensitivity values were all found to be significantly lower in the DN group (P < 0.001 for all parameters) at all quadrants as well as the central cornea. Furthermore, a moderate positive correlation between all five zones in the control group and a very strong positive correlation in the DN group were found in terms of the corneal quadrature sensitivity.
Conclusion: The current study revealed a significant reduction in corneal sensitivity in patients with DN. In both the control group and DN group, all corneal zones showed positive correlations which show the consistency of the measurement in different quadratures. Evaluating corneal sensitivity with a Cochet-Bonnet esthesiometer might serve as a useful screening tool in detecting neuropathy development. By taking the necessary precautions, further damage can be prevented.
期刊介绍:
The Middle East African Journal of Ophthalmology (MEAJO), published four times per year in print and online, is an official journal of the Middle East African Council of Ophthalmology (MEACO). It is an international, peer-reviewed journal whose mission includes publication of original research of interest to ophthalmologists in the Middle East and Africa, and to provide readers with high quality educational review articles from world-renown experts. MEAJO, previously known as Middle East Journal of Ophthalmology (MEJO) was founded by Dr Akef El Maghraby in 1993.