利用短延迟自外差干涉仪和多峰谷差精确测量线宽

Yu Hao Zhang, Xu Hua Cao, Wei Chen
{"title":"利用短延迟自外差干涉仪和多峰谷差精确测量线宽","authors":"Yu Hao Zhang, Xu Hua Cao, Wei Chen","doi":"10.1117/12.3006300","DOIUrl":null,"url":null,"abstract":"We propose a precision linewidths measurement using short-delay self-heterodyne interferometers and multiple peak-to-valley differences (MPVD). The method of MPVD of the coherent envelope to determine the laser linewidth is proved to be stable. Based on the relationship within MPVD values, the delay length and laser linewidth were calculated theoretically and via simulations. We also eliminate the effect of the broadened spectrum induced by the 1/f frequency noise and the influence of noise floor on the measurement using short-delay self-heterodyne techniques, providing MPVD that can satisfy high-precision measurements without being affected by noise. The results showed that this new method is capable of significantly improving the measurement accuracy of narrow linewidth.","PeriodicalId":298662,"journal":{"name":"Applied Optics and Photonics China","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precise linewidths measurement using short delay self-heterodyne interferometry and multiple peak-to-valley differences\",\"authors\":\"Yu Hao Zhang, Xu Hua Cao, Wei Chen\",\"doi\":\"10.1117/12.3006300\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We propose a precision linewidths measurement using short-delay self-heterodyne interferometers and multiple peak-to-valley differences (MPVD). The method of MPVD of the coherent envelope to determine the laser linewidth is proved to be stable. Based on the relationship within MPVD values, the delay length and laser linewidth were calculated theoretically and via simulations. We also eliminate the effect of the broadened spectrum induced by the 1/f frequency noise and the influence of noise floor on the measurement using short-delay self-heterodyne techniques, providing MPVD that can satisfy high-precision measurements without being affected by noise. The results showed that this new method is capable of significantly improving the measurement accuracy of narrow linewidth.\",\"PeriodicalId\":298662,\"journal\":{\"name\":\"Applied Optics and Photonics China\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Optics and Photonics China\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.3006300\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Optics and Photonics China","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.3006300","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们提出了一种利用短延迟自外差干涉仪和多峰谷差(MPVD)进行精确线宽测量的方法。通过相干包络的 MPVD 来确定激光线宽的方法被证明是稳定的。根据 MPVD 值之间的关系,理论和模拟计算出了延迟长度和激光线宽。我们还利用短延迟自外差技术消除了由 1/f 频率噪声引起的频谱增宽效应和本底噪声对测量的影响,提供了不受噪声影响、可满足高精度测量的 MPVD。结果表明,这种新方法能够显著提高窄线宽的测量精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Precise linewidths measurement using short delay self-heterodyne interferometry and multiple peak-to-valley differences
We propose a precision linewidths measurement using short-delay self-heterodyne interferometers and multiple peak-to-valley differences (MPVD). The method of MPVD of the coherent envelope to determine the laser linewidth is proved to be stable. Based on the relationship within MPVD values, the delay length and laser linewidth were calculated theoretically and via simulations. We also eliminate the effect of the broadened spectrum induced by the 1/f frequency noise and the influence of noise floor on the measurement using short-delay self-heterodyne techniques, providing MPVD that can satisfy high-precision measurements without being affected by noise. The results showed that this new method is capable of significantly improving the measurement accuracy of narrow linewidth.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信