R Günther, W Walter, K H Kloetzer, D Kob, J Schindler
{"title":"[192Ir线源的剂量学研究和剂量分布的数学表示]。","authors":"R Günther, W Walter, K H Kloetzer, D Kob, J Schindler","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The dose distribution of a \"line-shaped\" 192Ir-source was measured in 1,152 measuring points in a water phantom. Using regression analysis the analytical description of dose distribution was obtained. Accomplished comparison measurings with a solid phantom of miramide in 45 measuring points show that the dose distribution can be reproduced well by solid phantom measurings. Taking an ideal line source distribution as a basis, the r-dependence of correction factor, obtained by regression analysis, refers to a dispersion effect. The angle-dependent deviation of dose distribution from the ideal line source can be described by cos-terms with the single and double angle between line source axis and measuring point.</p>","PeriodicalId":76404,"journal":{"name":"Radiobiologia, radiotherapia","volume":"30 2","pages":"113-22"},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Dosimetric studies of 192Ir line sources and the mathematical presentation of the dose distribution].\",\"authors\":\"R Günther, W Walter, K H Kloetzer, D Kob, J Schindler\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The dose distribution of a \\\"line-shaped\\\" 192Ir-source was measured in 1,152 measuring points in a water phantom. Using regression analysis the analytical description of dose distribution was obtained. Accomplished comparison measurings with a solid phantom of miramide in 45 measuring points show that the dose distribution can be reproduced well by solid phantom measurings. Taking an ideal line source distribution as a basis, the r-dependence of correction factor, obtained by regression analysis, refers to a dispersion effect. The angle-dependent deviation of dose distribution from the ideal line source can be described by cos-terms with the single and double angle between line source axis and measuring point.</p>\",\"PeriodicalId\":76404,\"journal\":{\"name\":\"Radiobiologia, radiotherapia\",\"volume\":\"30 2\",\"pages\":\"113-22\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiobiologia, radiotherapia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiobiologia, radiotherapia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Dosimetric studies of 192Ir line sources and the mathematical presentation of the dose distribution].
The dose distribution of a "line-shaped" 192Ir-source was measured in 1,152 measuring points in a water phantom. Using regression analysis the analytical description of dose distribution was obtained. Accomplished comparison measurings with a solid phantom of miramide in 45 measuring points show that the dose distribution can be reproduced well by solid phantom measurings. Taking an ideal line source distribution as a basis, the r-dependence of correction factor, obtained by regression analysis, refers to a dispersion effect. The angle-dependent deviation of dose distribution from the ideal line source can be described by cos-terms with the single and double angle between line source axis and measuring point.