优化评估 MAFLD 患者肝脏脂肪变性的衰减系数的有效测量次数:对 139 名接受肝活检患者的研究。

IF 3.1 3区 医学 Q1 ACOUSTICS
Ultraschall in Der Medizin Pub Date : 2024-08-01 Epub Date: 2023-12-11 DOI:10.1055/a-2178-5022
Xueqi Li, Xianjue Huang, Guangwen Cheng, Jing Liang, Luping Qiu, Jubo Zhang, Qiyuan Yao, Hong Ding
{"title":"优化评估 MAFLD 患者肝脏脂肪变性的衰减系数的有效测量次数:对 139 名接受肝活检患者的研究。","authors":"Xueqi Li, Xianjue Huang, Guangwen Cheng, Jing Liang, Luping Qiu, Jubo Zhang, Qiyuan Yao, Hong Ding","doi":"10.1055/a-2178-5022","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We investigated the optimal number of valid measurements (VMs) for the attenuation coefficient (AC) to assess liver steatosis using attenuation imaging (ATI) and explored factors that may affect AC measurement in patients with metabolic dysfunction-associated fatty liver disease (MAFLD).</p><p><strong>Materials and methods: </strong>A total of 139 patients with MAFLD who underwent ATI and liver biopsy were enrolled. Hepatic steatosis was graded as S0-3 according to the SAF scoring system. The AC values from 1, 2, 3, 5, and 7 VMs were compared with the degree of liver steatosis. The correlation between AC values from different VMs was analyzed. The diagnostic performance of AC from different VMs at each steatosis grade was compared. The factors related to AC were identified using linear regression analysis.</p><p><strong>Results: </strong>The mean AC values from 1, 2, 3, 5, and 7 VMs were not significantly different between grades S0-3 (p=n.s. for all). Bland-Altman analysis showed the mean difference in AC values of 3 VMs and 7 VMs was 0.003 dB/cm/MHz, which was smaller compared with 2 VMs, and close to 5 VMs. The intraclass correlation coefficients of AC were all > 0.90 among different VM groups. AC values from different VMs all significantly predicted steatosis grade ≥S1, ≥S2, and S3 without significant statistical differences (p=n.s. for all). The multivariate analysis showed that the hepatic steatosis grade and triglyceride level were factors independently associated with AC.</p><p><strong>Conclusion: </strong>Three valid measurements of AC may be adequate to ensure the accuracy and reproducibility of hepatic steatosis assessment. The degree of liver steatosis and the triglyceride level significantly affected AC values.</p>","PeriodicalId":49400,"journal":{"name":"Ultraschall in Der Medizin","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11293898/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optimizing the number of valid measurements for the attenuation coefficient to assess hepatic steatosis in MAFLD patients: A study of 139 patients who underwent liver biopsy.\",\"authors\":\"Xueqi Li, Xianjue Huang, Guangwen Cheng, Jing Liang, Luping Qiu, Jubo Zhang, Qiyuan Yao, Hong Ding\",\"doi\":\"10.1055/a-2178-5022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We investigated the optimal number of valid measurements (VMs) for the attenuation coefficient (AC) to assess liver steatosis using attenuation imaging (ATI) and explored factors that may affect AC measurement in patients with metabolic dysfunction-associated fatty liver disease (MAFLD).</p><p><strong>Materials and methods: </strong>A total of 139 patients with MAFLD who underwent ATI and liver biopsy were enrolled. Hepatic steatosis was graded as S0-3 according to the SAF scoring system. The AC values from 1, 2, 3, 5, and 7 VMs were compared with the degree of liver steatosis. The correlation between AC values from different VMs was analyzed. The diagnostic performance of AC from different VMs at each steatosis grade was compared. The factors related to AC were identified using linear regression analysis.</p><p><strong>Results: </strong>The mean AC values from 1, 2, 3, 5, and 7 VMs were not significantly different between grades S0-3 (p=n.s. for all). Bland-Altman analysis showed the mean difference in AC values of 3 VMs and 7 VMs was 0.003 dB/cm/MHz, which was smaller compared with 2 VMs, and close to 5 VMs. The intraclass correlation coefficients of AC were all > 0.90 among different VM groups. AC values from different VMs all significantly predicted steatosis grade ≥S1, ≥S2, and S3 without significant statistical differences (p=n.s. for all). The multivariate analysis showed that the hepatic steatosis grade and triglyceride level were factors independently associated with AC.</p><p><strong>Conclusion: </strong>Three valid measurements of AC may be adequate to ensure the accuracy and reproducibility of hepatic steatosis assessment. The degree of liver steatosis and the triglyceride level significantly affected AC values.</p>\",\"PeriodicalId\":49400,\"journal\":{\"name\":\"Ultraschall in Der Medizin\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11293898/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultraschall in Der Medizin\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2178-5022\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultraschall in Der Medizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2178-5022","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/11 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:我们研究了利用衰减成像(ATI)评估肝脏脂肪变性的衰减系数(AC)的最佳有效测量次数(VMs),并探讨了可能影响代谢功能障碍相关性脂肪肝(MAFLD)患者AC测量的因素:共纳入139名接受ATI和肝活检的MAFLD患者。根据 SAF 评分系统,肝脏脂肪变性分为 S0-3 级。将 1、2、3、5 和 7 个 VM 的 AC 值与肝脏脂肪变性程度进行比较。分析了不同血管的 AC 值之间的相关性。比较了不同肝脏脂肪变性程度下不同 VM 的 AC 诊断性能。利用线性回归分析确定了与 AC 相关的因素:结果:来自 1、2、3、5 和 7 个 VM 的 AC 平均值在 S0-3 级之间没有显著差异(所有值的 p=n.s.)。Bland-Altman分析显示,3个VM和7个VM的平均交流值差异为0.003 dB/cm/MHz,与2个VM相比差异较小,与5个VM接近。不同 VM 组之间的 AC 类内相关系数均大于 0.90。不同 VM 的 AC 值均可显著预测脂肪变性分级≥S1、≥S2 和 S3,但无显著统计学差异(均为 p=n.s.)。多变量分析显示,肝脏脂肪变性分级和甘油三酯水平是与 AC 独立相关的因素:结论:三次有效的 AC 测量足以确保肝脏脂肪变性评估的准确性和可重复性。肝脏脂肪变性程度和甘油三酯水平对 AC 值有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimizing the number of valid measurements for the attenuation coefficient to assess hepatic steatosis in MAFLD patients: A study of 139 patients who underwent liver biopsy.

Purpose: We investigated the optimal number of valid measurements (VMs) for the attenuation coefficient (AC) to assess liver steatosis using attenuation imaging (ATI) and explored factors that may affect AC measurement in patients with metabolic dysfunction-associated fatty liver disease (MAFLD).

Materials and methods: A total of 139 patients with MAFLD who underwent ATI and liver biopsy were enrolled. Hepatic steatosis was graded as S0-3 according to the SAF scoring system. The AC values from 1, 2, 3, 5, and 7 VMs were compared with the degree of liver steatosis. The correlation between AC values from different VMs was analyzed. The diagnostic performance of AC from different VMs at each steatosis grade was compared. The factors related to AC were identified using linear regression analysis.

Results: The mean AC values from 1, 2, 3, 5, and 7 VMs were not significantly different between grades S0-3 (p=n.s. for all). Bland-Altman analysis showed the mean difference in AC values of 3 VMs and 7 VMs was 0.003 dB/cm/MHz, which was smaller compared with 2 VMs, and close to 5 VMs. The intraclass correlation coefficients of AC were all > 0.90 among different VM groups. AC values from different VMs all significantly predicted steatosis grade ≥S1, ≥S2, and S3 without significant statistical differences (p=n.s. for all). The multivariate analysis showed that the hepatic steatosis grade and triglyceride level were factors independently associated with AC.

Conclusion: Three valid measurements of AC may be adequate to ensure the accuracy and reproducibility of hepatic steatosis assessment. The degree of liver steatosis and the triglyceride level significantly affected AC values.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultraschall in Der Medizin
Ultraschall in Der Medizin 医学-核医学
CiteScore
5.30
自引率
8.80%
发文量
228
审稿时长
6-12 weeks
期刊介绍: Ultraschall in der Medizin / European Journal of Ultrasound publishes scientific papers and contributions from a variety of disciplines on the diagnostic and therapeutic applications of ultrasound with an emphasis on clinical application. Technical papers with a physiological theme as well as the interaction between ultrasound and biological systems might also occasionally be considered for peer review and publication, provided that the translational relevance is high and the link with clinical applications is tight. The editors and the publishers reserve the right to publish selected articles online only. Authors are welcome to submit supplementary video material. Letters and comments are also accepted, promoting a vivid exchange of opinions and scientific discussions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信