{"title":"自下而上加热的平整金属熔体层侧表面的修正努塞尔特数关系式","authors":"V. D. Loktionov","doi":"10.1134/S004060152312008X","DOIUrl":null,"url":null,"abstract":"<p>An analysis was made of the developed modified Nusselt number ratio Nu for estimating thermal loads on the surfaces of a flat horizontal layer of metal melt (liquid-metal coolants, metal melt layers formed inside nuclear power plant (NPP) containers during a severe accident, etc.), heated along its lower surface and having an uneven radial temperature distribution. The need for such an analysis is explained by the fact that the use of known relations for the Nusselt numbers Nu for a liquid/melt layer with an uneven longitudinal temperature distribution leads to significant errors in determining the heat transfer conditions at the boundary surfaces of the layer, which is critical, for example, when implementing the concept of retaining molten materials inside the nuclear power plant in case of a severe accident (SA). In the proposed relation for the Nu number on the lateral surface of the melt layer, both traditional (Rayleigh number) and additional parameters are used, taking into account the temperature conditions on its boundary surfaces (including the lateral one) as well as the dimensions of the layer. To find the unknown coefficients in the modified ratio, the results of several series of numerical experiments were used by the domestic ANES CFD code. Using the ratio obtained for the Nu number, a parametric analysis of the heat-transfer conditions on the side surface of the metal layer of the melt formed during an SA was carried out. According to the results of the analysis, the proposed ratio gives good accuracy in calculations (on average, the error did not exceed 7%) and the predictive efficiency of the developed modified ratio for Nu numbers in the range of Rayleigh numbers from 10<sup>6</sup> to 10<sup>12</sup>. Such a relation for the Nu numbers on the side surface of the melt layer can be used in assessing the thermal loads on the nuclear power plant container during an SA and in other problems where there is a radial nonuniformity of the temperature distribution in a flat liquid/melt layer heated from below.</p>","PeriodicalId":799,"journal":{"name":"Thermal Engineering","volume":"70 12","pages":"1019 - 1028"},"PeriodicalIF":0.9000,"publicationDate":"2023-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modified Relationship for Nusselt Numbers on the Side Surface of a Flat Metal Layer of Melt Heated from Below\",\"authors\":\"V. D. Loktionov\",\"doi\":\"10.1134/S004060152312008X\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>An analysis was made of the developed modified Nusselt number ratio Nu for estimating thermal loads on the surfaces of a flat horizontal layer of metal melt (liquid-metal coolants, metal melt layers formed inside nuclear power plant (NPP) containers during a severe accident, etc.), heated along its lower surface and having an uneven radial temperature distribution. The need for such an analysis is explained by the fact that the use of known relations for the Nusselt numbers Nu for a liquid/melt layer with an uneven longitudinal temperature distribution leads to significant errors in determining the heat transfer conditions at the boundary surfaces of the layer, which is critical, for example, when implementing the concept of retaining molten materials inside the nuclear power plant in case of a severe accident (SA). In the proposed relation for the Nu number on the lateral surface of the melt layer, both traditional (Rayleigh number) and additional parameters are used, taking into account the temperature conditions on its boundary surfaces (including the lateral one) as well as the dimensions of the layer. To find the unknown coefficients in the modified ratio, the results of several series of numerical experiments were used by the domestic ANES CFD code. Using the ratio obtained for the Nu number, a parametric analysis of the heat-transfer conditions on the side surface of the metal layer of the melt formed during an SA was carried out. According to the results of the analysis, the proposed ratio gives good accuracy in calculations (on average, the error did not exceed 7%) and the predictive efficiency of the developed modified ratio for Nu numbers in the range of Rayleigh numbers from 10<sup>6</sup> to 10<sup>12</sup>. Such a relation for the Nu numbers on the side surface of the melt layer can be used in assessing the thermal loads on the nuclear power plant container during an SA and in other problems where there is a radial nonuniformity of the temperature distribution in a flat liquid/melt layer heated from below.</p>\",\"PeriodicalId\":799,\"journal\":{\"name\":\"Thermal Engineering\",\"volume\":\"70 12\",\"pages\":\"1019 - 1028\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thermal Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S004060152312008X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thermal Engineering","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1134/S004060152312008X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

摘要 对已开发的修正努塞尔特数比 Nu 进行了分析,以估算沿下表面受热且径向温度分布不均的平 坦水平金属熔体层(液态金属冷却剂、严重事故期间在核电站容器内形成的金属熔体层 等)表面的热负荷。之所以需要进行这样的分析,是因为对于纵向温度分布不均匀的液体/熔体层,使用已知的努塞尔特数 Nu 关系会导致在确定该层边界表面的传热条件时出现重大误差,例如,在发生严重事故(SA)时,在核电厂内实施保留熔融材料的概念时,这一点至关重要。在提议的熔融层侧向表面 Nu 数关系中,既使用了传统参数(瑞利数),也使用了附加参数,同时考虑了熔融层边界表面(包括侧向表面)的温度条件以及熔融层的尺寸。为了找到修正比率中的未知系数,国内 ANES CFD 代码使用了多个系列的数值实验结果。利用获得的 Nu 数比率,对 SA 过程中形成的熔体金属层侧表面的传热条件进行了参数分析。分析结果表明,所建议的比率具有良好的计算精度(平均误差不超过 7%),并且所开发的修正比率对雷利数范围在 106 到 1012 之间的 Nu 数具有很高的预测效率。这种熔体层侧表面的 Nu 数关系可用于评估 SA 期间核电站容器上的热负荷,也可用于从下方加热的平面液体/熔体层中温度分布存在径向不均匀性的其他问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Modified Relationship for Nusselt Numbers on the Side Surface of a Flat Metal Layer of Melt Heated from Below

Modified Relationship for Nusselt Numbers on the Side Surface of a Flat Metal Layer of Melt Heated from Below

An analysis was made of the developed modified Nusselt number ratio Nu for estimating thermal loads on the surfaces of a flat horizontal layer of metal melt (liquid-metal coolants, metal melt layers formed inside nuclear power plant (NPP) containers during a severe accident, etc.), heated along its lower surface and having an uneven radial temperature distribution. The need for such an analysis is explained by the fact that the use of known relations for the Nusselt numbers Nu for a liquid/melt layer with an uneven longitudinal temperature distribution leads to significant errors in determining the heat transfer conditions at the boundary surfaces of the layer, which is critical, for example, when implementing the concept of retaining molten materials inside the nuclear power plant in case of a severe accident (SA). In the proposed relation for the Nu number on the lateral surface of the melt layer, both traditional (Rayleigh number) and additional parameters are used, taking into account the temperature conditions on its boundary surfaces (including the lateral one) as well as the dimensions of the layer. To find the unknown coefficients in the modified ratio, the results of several series of numerical experiments were used by the domestic ANES CFD code. Using the ratio obtained for the Nu number, a parametric analysis of the heat-transfer conditions on the side surface of the metal layer of the melt formed during an SA was carried out. According to the results of the analysis, the proposed ratio gives good accuracy in calculations (on average, the error did not exceed 7%) and the predictive efficiency of the developed modified ratio for Nu numbers in the range of Rayleigh numbers from 106 to 1012. Such a relation for the Nu numbers on the side surface of the melt layer can be used in assessing the thermal loads on the nuclear power plant container during an SA and in other problems where there is a radial nonuniformity of the temperature distribution in a flat liquid/melt layer heated from below.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.30
自引率
20.00%
发文量
94
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信