电化学生成的铝--用于修复含有 2,4-二氯苯酚的废水

H. Simol, R. A. Jahan
{"title":"电化学生成的铝--用于修复含有 2,4-二氯苯酚的废水","authors":"H. Simol, R. A. Jahan","doi":"10.9734/ajocs/2023/v13i6274","DOIUrl":null,"url":null,"abstract":"An effective treatment process for 2,4-dichlorophenol (2,4-DCP) in wastewater is highly essential, since it may cause great threat to our environment. In such context, a low-cost potential and environment-friendly technique has been demonstrated for the removal of a toxic compound 2,4-DCP from aqueous media. The electrochemically generated aluminum sorbent was used to remove 2,4-DCP from waste water by in-situ electrocoagulation and by adsorption. The experimental findings were analyzed based on the percent removal of 2,4-DCP with time. DCP-containing wastewater was electrocoagulated in a two-electrode monopolar electrocoagulation cell with aluminum as the sacrificial anode and 0.05 M NaCl as the internal electrolyte, with the electrolyte concentration kept constant throughout the experiment. Starting concentration and pH were found to have a significant impact on the electrocoagulation process for removing 2,4-DCP from wastewater.","PeriodicalId":8505,"journal":{"name":"Asian Journal of Chemical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrochemically Generated Aluminum-Species for Remediation of Waste Water Containing 2, 4-Dichlorophenol\",\"authors\":\"H. Simol, R. A. Jahan\",\"doi\":\"10.9734/ajocs/2023/v13i6274\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An effective treatment process for 2,4-dichlorophenol (2,4-DCP) in wastewater is highly essential, since it may cause great threat to our environment. In such context, a low-cost potential and environment-friendly technique has been demonstrated for the removal of a toxic compound 2,4-DCP from aqueous media. The electrochemically generated aluminum sorbent was used to remove 2,4-DCP from waste water by in-situ electrocoagulation and by adsorption. The experimental findings were analyzed based on the percent removal of 2,4-DCP with time. DCP-containing wastewater was electrocoagulated in a two-electrode monopolar electrocoagulation cell with aluminum as the sacrificial anode and 0.05 M NaCl as the internal electrolyte, with the electrolyte concentration kept constant throughout the experiment. Starting concentration and pH were found to have a significant impact on the electrocoagulation process for removing 2,4-DCP from wastewater.\",\"PeriodicalId\":8505,\"journal\":{\"name\":\"Asian Journal of Chemical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Chemical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9734/ajocs/2023/v13i6274\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Chemical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/ajocs/2023/v13i6274","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

废水中2,4-二氯酚(2,4- dcp)的有效处理工艺是非常必要的,因为它可能对我们的环境造成很大的威胁。在这种情况下,一种低成本、环保的技术已经被证明可以从水介质中去除有毒化合物2,4-二氯苯酚。采用原位电絮凝和吸附两种方法对废水中的2,4-二氯苯酚进行了电化学合成铝吸附剂的去除。根据2,4- dcp去除率随时间的变化对实验结果进行了分析。以铝为牺牲阳极,0.05 M NaCl为内电解质,在双电极单极电凝池中对含dcp废水进行电凝处理,整个实验过程中保持电解质浓度不变。研究发现,初始浓度和pH值对电凝法去除废水中2,4-二氯苯酚有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrochemically Generated Aluminum-Species for Remediation of Waste Water Containing 2, 4-Dichlorophenol
An effective treatment process for 2,4-dichlorophenol (2,4-DCP) in wastewater is highly essential, since it may cause great threat to our environment. In such context, a low-cost potential and environment-friendly technique has been demonstrated for the removal of a toxic compound 2,4-DCP from aqueous media. The electrochemically generated aluminum sorbent was used to remove 2,4-DCP from waste water by in-situ electrocoagulation and by adsorption. The experimental findings were analyzed based on the percent removal of 2,4-DCP with time. DCP-containing wastewater was electrocoagulated in a two-electrode monopolar electrocoagulation cell with aluminum as the sacrificial anode and 0.05 M NaCl as the internal electrolyte, with the electrolyte concentration kept constant throughout the experiment. Starting concentration and pH were found to have a significant impact on the electrocoagulation process for removing 2,4-DCP from wastewater.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信