{"title":"离子触发原位凝胶的制备与评估:盐酸环丙沙星和盐酸奥洛他定的有效眼部给药组合","authors":"D. A. Shaikh, Munira M. M. Momin","doi":"10.2174/0122103031267809231128111259","DOIUrl":null,"url":null,"abstract":"\n\nOcular in situ gels (ISG) are an adequate substitute to overcome the pitfalls of conventional eye drops as they acquaintance the advantages of solutions, including accuracy, dosing frequency, and ease of administration with prolonged contact with the ocular membrane.\n\n\n\nThe present investigation aims to develop the ion-triggered in situ gel (ITISG) system for the convenient administration of Ciprofloxacin HCl (CFH) and Olopatadine HCl (OLH) in combination by employing gellan gum to prolong the pre-corneal residence, optic bioavailability and declines dosing frequency.\n\n\n\nThe ISG material and critical quality attributes (CQA) were identified. Quality by Design (QbD) was established to optimize the formulation. Nine experimental formulations were designed (F1-F9) and assigned to distinct physicochemical and in vitro examinations\n\n\n\nOptimized batch F2 exhibited all the findings within acceptable limits. The Ion-triggered ISG technique exhibits maximum drug release over a 240-min cycle, much more significant than conventional eyedrops (60 min), suggesting sustained drug distribution and superior corneal penetration and absorption.\n\n\n\nComprehensive findings of the present investigation conclude that the CFH and OLH would be effectively formulated as an ion-triggered ISG system to manage several draw-backs associated with prolonged release, ocular retention, and better corneal penetration com-pared with conventional eyedrops.\n","PeriodicalId":11310,"journal":{"name":"Drug Delivery Letters","volume":"83 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Formulation and Evaluation of Ion-Triggered In situ gel for Effective Ocular Delivery of Ciprofloxacin HCl and Olopatadine HCl in Combination\",\"authors\":\"D. A. Shaikh, Munira M. M. Momin\",\"doi\":\"10.2174/0122103031267809231128111259\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n\\nOcular in situ gels (ISG) are an adequate substitute to overcome the pitfalls of conventional eye drops as they acquaintance the advantages of solutions, including accuracy, dosing frequency, and ease of administration with prolonged contact with the ocular membrane.\\n\\n\\n\\nThe present investigation aims to develop the ion-triggered in situ gel (ITISG) system for the convenient administration of Ciprofloxacin HCl (CFH) and Olopatadine HCl (OLH) in combination by employing gellan gum to prolong the pre-corneal residence, optic bioavailability and declines dosing frequency.\\n\\n\\n\\nThe ISG material and critical quality attributes (CQA) were identified. Quality by Design (QbD) was established to optimize the formulation. Nine experimental formulations were designed (F1-F9) and assigned to distinct physicochemical and in vitro examinations\\n\\n\\n\\nOptimized batch F2 exhibited all the findings within acceptable limits. The Ion-triggered ISG technique exhibits maximum drug release over a 240-min cycle, much more significant than conventional eyedrops (60 min), suggesting sustained drug distribution and superior corneal penetration and absorption.\\n\\n\\n\\nComprehensive findings of the present investigation conclude that the CFH and OLH would be effectively formulated as an ion-triggered ISG system to manage several draw-backs associated with prolonged release, ocular retention, and better corneal penetration com-pared with conventional eyedrops.\\n\",\"PeriodicalId\":11310,\"journal\":{\"name\":\"Drug Delivery Letters\",\"volume\":\"83 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drug Delivery Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/0122103031267809231128111259\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Pharmacology, Toxicology and Pharmaceutics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Delivery Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/0122103031267809231128111259","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

摘要

眼原位凝胶(ISG)是克服传统滴眼液缺陷的适当替代品,因为它们了解溶液的优点,包括准确性,给药频率,易于与眼膜长时间接触。本研究旨在利用结冷胶延长环丙沙星(CFH)和奥洛帕他定(OLH)在角膜前的停留时间、光学生物利用度和降低给药频率,建立离子触发原位凝胶(ITISG)系统,方便环丙沙星(CFH)和奥洛帕他定(OLH)联合给药。确定了ISG材料和关键质量属性(CQA)。建立质量设计法(QbD),对配方进行优化。设计了9个实验配方(F1-F9),并进行了不同的理化和体外检查,优化批次F2的所有结果都在可接受的范围内。离子触发ISG技术在240分钟的周期内显示出最大的药物释放,比传统滴眼液(60分钟)显著得多,表明药物持续分布和更好的角膜渗透和吸收。本研究的综合结果表明,与传统滴眼液相比,CFH和OLH可以有效地作为离子触发的ISG系统来管理与释放时间延长、眼潴留和更好的角膜穿透有关的几个缺点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Formulation and Evaluation of Ion-Triggered In situ gel for Effective Ocular Delivery of Ciprofloxacin HCl and Olopatadine HCl in Combination
Ocular in situ gels (ISG) are an adequate substitute to overcome the pitfalls of conventional eye drops as they acquaintance the advantages of solutions, including accuracy, dosing frequency, and ease of administration with prolonged contact with the ocular membrane. The present investigation aims to develop the ion-triggered in situ gel (ITISG) system for the convenient administration of Ciprofloxacin HCl (CFH) and Olopatadine HCl (OLH) in combination by employing gellan gum to prolong the pre-corneal residence, optic bioavailability and declines dosing frequency. The ISG material and critical quality attributes (CQA) were identified. Quality by Design (QbD) was established to optimize the formulation. Nine experimental formulations were designed (F1-F9) and assigned to distinct physicochemical and in vitro examinations Optimized batch F2 exhibited all the findings within acceptable limits. The Ion-triggered ISG technique exhibits maximum drug release over a 240-min cycle, much more significant than conventional eyedrops (60 min), suggesting sustained drug distribution and superior corneal penetration and absorption. Comprehensive findings of the present investigation conclude that the CFH and OLH would be effectively formulated as an ion-triggered ISG system to manage several draw-backs associated with prolonged release, ocular retention, and better corneal penetration com-pared with conventional eyedrops.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Drug Delivery Letters
Drug Delivery Letters Pharmacology, Toxicology and Pharmaceutics-Pharmacology, Toxicology and Pharmaceutics (miscellaneous)
CiteScore
1.70
自引率
0.00%
发文量
30
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信