根据 SYNOP 报告和 PERUN 闪电探测系统对波兰雷暴日进行比较

IF 0.6 Q3 GEOGRAPHY
Sławomir Sulik, M. Kejna
{"title":"根据 SYNOP 报告和 PERUN 闪电探测系统对波兰雷暴日进行比较","authors":"Sławomir Sulik, M. Kejna","doi":"10.2478/mgrsd-2023-0019","DOIUrl":null,"url":null,"abstract":"Abstract The research presents a comparison between two methods which are used to identify days on which there are thunderstorms (TDs) in Poland. SYNOP and PERUN lightning network data from the Institute of Meteorology and Water Management (IMGW-PIB) for the period 2002–2020 were used to determine and compare the changes in the number of TDs. To determine the number of TDs using the PERUN data, an appropriate method needed to be created which would allow for the closest possible reference to human perception in relation to lightning. A buffer with a radius of 15 km was used, and TDs were counted when there was at least one flash within the buffer circle. Measurements performed by observers are sometimes not homogeneous and are prone to errors, and thus underestimate the actual number of TDs. As a result of the analysis, the average number of TDs in Poland was found to be 26 (SYNOP) and 30 (PERUN) per year.","PeriodicalId":44469,"journal":{"name":"Miscellanea Geographica","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2023-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of thunderstorm days in Poland based on SYNOP reports and PERUN lightning detection system\",\"authors\":\"Sławomir Sulik, M. Kejna\",\"doi\":\"10.2478/mgrsd-2023-0019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The research presents a comparison between two methods which are used to identify days on which there are thunderstorms (TDs) in Poland. SYNOP and PERUN lightning network data from the Institute of Meteorology and Water Management (IMGW-PIB) for the period 2002–2020 were used to determine and compare the changes in the number of TDs. To determine the number of TDs using the PERUN data, an appropriate method needed to be created which would allow for the closest possible reference to human perception in relation to lightning. A buffer with a radius of 15 km was used, and TDs were counted when there was at least one flash within the buffer circle. Measurements performed by observers are sometimes not homogeneous and are prone to errors, and thus underestimate the actual number of TDs. As a result of the analysis, the average number of TDs in Poland was found to be 26 (SYNOP) and 30 (PERUN) per year.\",\"PeriodicalId\":44469,\"journal\":{\"name\":\"Miscellanea Geographica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-12-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Miscellanea Geographica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/mgrsd-2023-0019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GEOGRAPHY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Miscellanea Geographica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/mgrsd-2023-0019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GEOGRAPHY","Score":null,"Total":0}
引用次数: 0

摘要

摘要:研究提出了两种方法之间的比较,这是用来确定有雷暴(td)在波兰的日子。利用2002-2020年气象和水管理研究所(IMGW-PIB)的SYNOP和PERUN闪电网数据确定和比较了td数量的变化。为了利用PERUN数据确定td的数量,需要创建一种适当的方法,以尽可能接近人类对闪电的感知。使用半径为15 km的缓冲圈,当缓冲圈内至少出现一次闪光时,计算TDs。观测者进行的测量有时不是均匀的,容易出错,因此低估了td的实际数量。分析结果显示,波兰的TDs平均数量为每年26例(SYNOP)和30例(PERUN)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of thunderstorm days in Poland based on SYNOP reports and PERUN lightning detection system
Abstract The research presents a comparison between two methods which are used to identify days on which there are thunderstorms (TDs) in Poland. SYNOP and PERUN lightning network data from the Institute of Meteorology and Water Management (IMGW-PIB) for the period 2002–2020 were used to determine and compare the changes in the number of TDs. To determine the number of TDs using the PERUN data, an appropriate method needed to be created which would allow for the closest possible reference to human perception in relation to lightning. A buffer with a radius of 15 km was used, and TDs were counted when there was at least one flash within the buffer circle. Measurements performed by observers are sometimes not homogeneous and are prone to errors, and thus underestimate the actual number of TDs. As a result of the analysis, the average number of TDs in Poland was found to be 26 (SYNOP) and 30 (PERUN) per year.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
21
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信