胃肠内窥镜介入功能诊断:将内窥镜套件中的诊断和治疗工具与功能性管腔成像探头相结合

IF 4 3区 医学 Q1 PHARMACOLOGY & PHARMACY
Zuzana Vackova , Ian Levenfus , Daniel Pohl
{"title":"胃肠内窥镜介入功能诊断:将内窥镜套件中的诊断和治疗工具与功能性管腔成像探头相结合","authors":"Zuzana Vackova ,&nbsp;Ian Levenfus ,&nbsp;Daniel Pohl","doi":"10.1016/j.coph.2023.102414","DOIUrl":null,"url":null,"abstract":"<div><p>With technical progress of gastrointestinal functional testing, there has been a demand for more comprehensive examination of esophageal physiology and pathophysiology beyond high-resolution manometry. A new interventional technology based on impedance planimetry, the functional lumen imaging probe (FLIP), enables intraluminal measurement of distensibility and compliance of hollow organs. EndoFLIP uses balloon catheters to measure diameter and distension pressure to calculate cross-sectional area and distensibility in different organs (mostly esophagus, stomach, anorectal region) and can be used in wide variety of indications (diagnostics, pre- and post-treatment evaluation) and currently serves as a helpful adjunctive tool in ambiguous clinical cases. EsoFLIP is a therapeutic variation that uses a stiffer balloon catheter allowing for dilation. The trend to simplify the clinical process from diagnosis to treatment tends to a one-session procedure combining diagnostics and therapeutic interventions. In specified conditions like e.g. achalasia or gastroparesis, a combination of EndoFLIP and EsoFLIP procedures may therefore be useful. The aim of this narrative review is to introduce the clinical use of FLIP and its potential benefit in combined diagnostic-therapeutic procedures.</p></div>","PeriodicalId":50603,"journal":{"name":"Current Opinion in Pharmacology","volume":null,"pages":null},"PeriodicalIF":4.0000,"publicationDate":"2023-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1471489223000693/pdfft?md5=a85fbc9fb6d7221a1db26a1995fcc341&pid=1-s2.0-S1471489223000693-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Interventional functional diagnostics in gastrointestinal endoscopy: Combining diagnostic and therapeutic tools in the endoscopy suite with the functional lumen imaging probe\",\"authors\":\"Zuzana Vackova ,&nbsp;Ian Levenfus ,&nbsp;Daniel Pohl\",\"doi\":\"10.1016/j.coph.2023.102414\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>With technical progress of gastrointestinal functional testing, there has been a demand for more comprehensive examination of esophageal physiology and pathophysiology beyond high-resolution manometry. A new interventional technology based on impedance planimetry, the functional lumen imaging probe (FLIP), enables intraluminal measurement of distensibility and compliance of hollow organs. EndoFLIP uses balloon catheters to measure diameter and distension pressure to calculate cross-sectional area and distensibility in different organs (mostly esophagus, stomach, anorectal region) and can be used in wide variety of indications (diagnostics, pre- and post-treatment evaluation) and currently serves as a helpful adjunctive tool in ambiguous clinical cases. EsoFLIP is a therapeutic variation that uses a stiffer balloon catheter allowing for dilation. The trend to simplify the clinical process from diagnosis to treatment tends to a one-session procedure combining diagnostics and therapeutic interventions. In specified conditions like e.g. achalasia or gastroparesis, a combination of EndoFLIP and EsoFLIP procedures may therefore be useful. The aim of this narrative review is to introduce the clinical use of FLIP and its potential benefit in combined diagnostic-therapeutic procedures.</p></div>\",\"PeriodicalId\":50603,\"journal\":{\"name\":\"Current Opinion in Pharmacology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2023-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1471489223000693/pdfft?md5=a85fbc9fb6d7221a1db26a1995fcc341&pid=1-s2.0-S1471489223000693-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Opinion in Pharmacology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1471489223000693\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Opinion in Pharmacology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1471489223000693","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

随着胃肠功能检测技术的进步,人们要求在高分辨率测压法之外,对食管生理和病理生理进行更全面的检查。一种基于阻抗平面测量的新型介入技术——功能性管腔成像探针(FLIP),可以在腔内测量中空器官的扩张性和顺应性。EndoFLIP使用球囊导管测量直径和扩张压力,计算不同器官(主要是食道、胃、肛肠区域)的横截面积和扩张率,可用于各种适应症(诊断、治疗前和治疗后评估),目前是临床上模棱两可病例的辅助工具。EsoFLIP是一种治疗性的变体,使用更硬的球囊导管进行扩张。简化从诊断到治疗的临床过程的趋势趋向于将诊断和治疗干预相结合的一次会议程序。在特定的情况下,如贲门失弛缓症或胃轻瘫,EndoFLIP和EsoFLIP手术的组合可能是有用的。这篇叙述性综述的目的是介绍FLIP的临床应用及其在联合诊断和治疗过程中的潜在益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Interventional functional diagnostics in gastrointestinal endoscopy: Combining diagnostic and therapeutic tools in the endoscopy suite with the functional lumen imaging probe

With technical progress of gastrointestinal functional testing, there has been a demand for more comprehensive examination of esophageal physiology and pathophysiology beyond high-resolution manometry. A new interventional technology based on impedance planimetry, the functional lumen imaging probe (FLIP), enables intraluminal measurement of distensibility and compliance of hollow organs. EndoFLIP uses balloon catheters to measure diameter and distension pressure to calculate cross-sectional area and distensibility in different organs (mostly esophagus, stomach, anorectal region) and can be used in wide variety of indications (diagnostics, pre- and post-treatment evaluation) and currently serves as a helpful adjunctive tool in ambiguous clinical cases. EsoFLIP is a therapeutic variation that uses a stiffer balloon catheter allowing for dilation. The trend to simplify the clinical process from diagnosis to treatment tends to a one-session procedure combining diagnostics and therapeutic interventions. In specified conditions like e.g. achalasia or gastroparesis, a combination of EndoFLIP and EsoFLIP procedures may therefore be useful. The aim of this narrative review is to introduce the clinical use of FLIP and its potential benefit in combined diagnostic-therapeutic procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.80
自引率
2.50%
发文量
131
审稿时长
4-8 weeks
期刊介绍: Current Opinion in Pharmacology (COPHAR) publishes authoritative, comprehensive, and systematic reviews. COPHAR helps specialists keep up to date with a clear and readable synthesis on current advances in pharmacology and drug discovery. Expert authors annotate the most interesting papers from the expanding volume of information published today, saving valuable time and giving the reader insight on areas of importance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信