印度北部一家三级医院工作人员的噪音水平和烦恼:一项横断面研究。

Aritrik Das, Jugal Kishore
{"title":"印度北部一家三级医院工作人员的噪音水平和烦恼:一项横断面研究。","authors":"Aritrik Das, Jugal Kishore","doi":"10.1080/19338244.2023.2286388","DOIUrl":null,"url":null,"abstract":"<p><p>Hospital noise has remained a low priority problem in India. An area of not less than 100 meters around a hospital is considered a silence zone, with guidelines restricting noise levels at 50dBA during daytime and 40dBA during the night. World Health Organization (WHO) guidelines also stipulate an average of 30dBA and a maximum of 40dbA. Annoyance is a known effect of noise exposure. However, very few studies have attempted to explore the hospital soundscape and the annoyance among staff related to it. Noise data was collected from 30 sites, using a Digital Integrating Sound Level Meter, LutronSL-4035SD (ISO-9001,CE,IEC1010) meeting IEC61672 standards. Stratified random sampling of staff was done on basis of noise exposure. A pre-designed, semi-structured questionnaire collected information on sociodemographic and work profile. Annoyance was defined as a stress reaction to environmental noise and was measured using standardized general purpose noise reaction questionnaire (ISO-TS/15666). Data was analyzed in SPSS. The mean L<sub>Aeq</sub> 24 h across all the sites was 69.5dBA (SD ±5.8dBA) for the weekdays and 66.2dBA (SD ±4.6dBA) for the weekends. Noise levels were higher during the day than during the night, and higher during the weekdays as compared to the weekends. 332(73.8%) study participants were found to be annoyed due to hospital noise. Annoyance among study participants was significantly associated with L<sub>Aeq</sub> 24 h > 80 dBA during the weekdays [aOR = 5.08 (1.17-22.06)] and L<sub>Aeq</sub> 24 h of 65-80 dBA during the weekends [aOR = 2.71 (1.46-5.01)]. Noise levels in the hospital far exceeded WHO and Central Pollution Control Board (CPCB) guidelines recommended for indoor hospital noise, as well as the national guidelines for sensitive zones. Almost three-fourth of the study participants were annoyed due to hospital noise. Significant association was found between annoyance among staff and higher noise levels of their workplace. Similar studies need to be conducted in hospitals across India to generate evidence on the current situtation and identify solutions.</p>","PeriodicalId":93879,"journal":{"name":"Archives of environmental & occupational health","volume":" ","pages":"471-482"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Noise levels and annoyance among staff in a tertiary care hospital in North India: A cross-sectional study.\",\"authors\":\"Aritrik Das, Jugal Kishore\",\"doi\":\"10.1080/19338244.2023.2286388\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Hospital noise has remained a low priority problem in India. An area of not less than 100 meters around a hospital is considered a silence zone, with guidelines restricting noise levels at 50dBA during daytime and 40dBA during the night. World Health Organization (WHO) guidelines also stipulate an average of 30dBA and a maximum of 40dbA. Annoyance is a known effect of noise exposure. However, very few studies have attempted to explore the hospital soundscape and the annoyance among staff related to it. Noise data was collected from 30 sites, using a Digital Integrating Sound Level Meter, LutronSL-4035SD (ISO-9001,CE,IEC1010) meeting IEC61672 standards. Stratified random sampling of staff was done on basis of noise exposure. A pre-designed, semi-structured questionnaire collected information on sociodemographic and work profile. Annoyance was defined as a stress reaction to environmental noise and was measured using standardized general purpose noise reaction questionnaire (ISO-TS/15666). Data was analyzed in SPSS. The mean L<sub>Aeq</sub> 24 h across all the sites was 69.5dBA (SD ±5.8dBA) for the weekdays and 66.2dBA (SD ±4.6dBA) for the weekends. Noise levels were higher during the day than during the night, and higher during the weekdays as compared to the weekends. 332(73.8%) study participants were found to be annoyed due to hospital noise. Annoyance among study participants was significantly associated with L<sub>Aeq</sub> 24 h > 80 dBA during the weekdays [aOR = 5.08 (1.17-22.06)] and L<sub>Aeq</sub> 24 h of 65-80 dBA during the weekends [aOR = 2.71 (1.46-5.01)]. Noise levels in the hospital far exceeded WHO and Central Pollution Control Board (CPCB) guidelines recommended for indoor hospital noise, as well as the national guidelines for sensitive zones. Almost three-fourth of the study participants were annoyed due to hospital noise. Significant association was found between annoyance among staff and higher noise levels of their workplace. Similar studies need to be conducted in hospitals across India to generate evidence on the current situtation and identify solutions.</p>\",\"PeriodicalId\":93879,\"journal\":{\"name\":\"Archives of environmental & occupational health\",\"volume\":\" \",\"pages\":\"471-482\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of environmental & occupational health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/19338244.2023.2286388\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of environmental & occupational health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/19338244.2023.2286388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/7 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

医院噪音在印度仍然是一个不太重要的问题。医院周围不少于100米的区域被认为是安静区,指导方针将噪音水平限制在白天50dBA,晚上40dBA。世界卫生组织(WHO)的指导方针也规定了平均30dBA和最高40dbA。烦恼是暴露在噪音中的一种已知影响。然而,很少有研究试图探讨医院的音景和与之相关的员工的烦恼。使用符合IEC61672标准的数字集成声级计lutreon - 4035sd (ISO-9001,CE,IEC1010)从30个站点收集噪声数据。根据噪声暴露情况对工作人员进行分层随机抽样。预先设计的半结构化问卷收集了社会人口统计和工作概况的信息。烦恼被定义为对环境噪声的应激反应,采用标准化通用噪声反应问卷(ISO-TS/15666)进行测量。数据用SPSS进行分析。24 h平均LAeq在工作日为69.5dBA (SD±5.8dBA),在周末为66.2dBA (SD±4.6dBA)。白天的噪音水平比晚上高,工作日的噪音水平比周末高。332名(73.8%)研究参与者被发现因医院噪音而烦恼。研究参与者的烦恼与工作日LAeq 24小时> 80 dBA [aOR = 5.08(1.17-22.06)]和周末LAeq 24小时> 65-80 dBA [aOR = 2.71(1.46-5.01)]显著相关。医院的噪音水平远远超过世卫组织和中央污染控制委员会建议的医院室内噪音准则,以及敏感地区的国家准则。近四分之三的研究参与者因医院的噪音而感到烦恼。研究发现,员工的烦恼与工作场所的高噪音水平之间存在显著关联。需要在印度各地的医院进行类似的研究,以得出关于目前情况的证据并确定解决办法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Noise levels and annoyance among staff in a tertiary care hospital in North India: A cross-sectional study.

Hospital noise has remained a low priority problem in India. An area of not less than 100 meters around a hospital is considered a silence zone, with guidelines restricting noise levels at 50dBA during daytime and 40dBA during the night. World Health Organization (WHO) guidelines also stipulate an average of 30dBA and a maximum of 40dbA. Annoyance is a known effect of noise exposure. However, very few studies have attempted to explore the hospital soundscape and the annoyance among staff related to it. Noise data was collected from 30 sites, using a Digital Integrating Sound Level Meter, LutronSL-4035SD (ISO-9001,CE,IEC1010) meeting IEC61672 standards. Stratified random sampling of staff was done on basis of noise exposure. A pre-designed, semi-structured questionnaire collected information on sociodemographic and work profile. Annoyance was defined as a stress reaction to environmental noise and was measured using standardized general purpose noise reaction questionnaire (ISO-TS/15666). Data was analyzed in SPSS. The mean LAeq 24 h across all the sites was 69.5dBA (SD ±5.8dBA) for the weekdays and 66.2dBA (SD ±4.6dBA) for the weekends. Noise levels were higher during the day than during the night, and higher during the weekdays as compared to the weekends. 332(73.8%) study participants were found to be annoyed due to hospital noise. Annoyance among study participants was significantly associated with LAeq 24 h > 80 dBA during the weekdays [aOR = 5.08 (1.17-22.06)] and LAeq 24 h of 65-80 dBA during the weekends [aOR = 2.71 (1.46-5.01)]. Noise levels in the hospital far exceeded WHO and Central Pollution Control Board (CPCB) guidelines recommended for indoor hospital noise, as well as the national guidelines for sensitive zones. Almost three-fourth of the study participants were annoyed due to hospital noise. Significant association was found between annoyance among staff and higher noise levels of their workplace. Similar studies need to be conducted in hospitals across India to generate evidence on the current situtation and identify solutions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信