Xiaojun Lu, Shuguang Piao, ShenFei Qin, KaiXuan Zhang, JiaCheng Li, WenHao Zhou, Lei Tang, Shi Yan, Yuangui Chen, Guonan Yin, Tie Zhou
{"title":"成年男性一次性包皮环切缝合器的系带保护技术。","authors":"Xiaojun Lu, Shuguang Piao, ShenFei Qin, KaiXuan Zhang, JiaCheng Li, WenHao Zhou, Lei Tang, Shi Yan, Yuangui Chen, Guonan Yin, Tie Zhou","doi":"10.22037/uj.v20i.7788","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the efficacy of frenulum protection technique of the disposable circumcision suture device (DCSD) in adult males.</p><p><strong>Materials and methods: </strong>Atotal of 53 adult males were diagnosed with redundant prepuce and underwent circumcision with DCSD using frenulum protection technique. The main preoperative and postoperative measure of the length of penile frenulum was evaluated. Other data such as edema rate, intraoperative blood loss, operation time, postoperative pain, staple falling off time, incision infection rate, and evaluation of satisfaction rate with penis appearance were documented in the study.</p><p><strong>Results: </strong>There was no significant difference in preoperative and postoperative frenulum length for each patient. The mean length of the penile frenulum before and after surgery was 2.25 ± 0.36 cm and 2.23 ± 0.39 cm, respectively (p = .31). The rate of frenulum length preservation was 100%. All the patients had no excessive resection of the frenulum and no serious complication happened after surgery. The satisfaction rate of postoperative penis appearance from patients' evaluation was 98.1% (52/53).</p><p><strong>Conclusion: </strong>The frenulum protection technique was simple and operable, which could help the operator to accurately identify the most distal position of the frenulum and retain a sufficient length of frenulum during DCSD circumcision.</p>","PeriodicalId":23416,"journal":{"name":"Urology Journal","volume":" ","pages":"424-428"},"PeriodicalIF":1.5000,"publicationDate":"2023-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Frenulum Protection Technique in Disposable Circumcision Suture Device for Adult Males.\",\"authors\":\"Xiaojun Lu, Shuguang Piao, ShenFei Qin, KaiXuan Zhang, JiaCheng Li, WenHao Zhou, Lei Tang, Shi Yan, Yuangui Chen, Guonan Yin, Tie Zhou\",\"doi\":\"10.22037/uj.v20i.7788\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the efficacy of frenulum protection technique of the disposable circumcision suture device (DCSD) in adult males.</p><p><strong>Materials and methods: </strong>Atotal of 53 adult males were diagnosed with redundant prepuce and underwent circumcision with DCSD using frenulum protection technique. The main preoperative and postoperative measure of the length of penile frenulum was evaluated. Other data such as edema rate, intraoperative blood loss, operation time, postoperative pain, staple falling off time, incision infection rate, and evaluation of satisfaction rate with penis appearance were documented in the study.</p><p><strong>Results: </strong>There was no significant difference in preoperative and postoperative frenulum length for each patient. The mean length of the penile frenulum before and after surgery was 2.25 ± 0.36 cm and 2.23 ± 0.39 cm, respectively (p = .31). The rate of frenulum length preservation was 100%. All the patients had no excessive resection of the frenulum and no serious complication happened after surgery. The satisfaction rate of postoperative penis appearance from patients' evaluation was 98.1% (52/53).</p><p><strong>Conclusion: </strong>The frenulum protection technique was simple and operable, which could help the operator to accurately identify the most distal position of the frenulum and retain a sufficient length of frenulum during DCSD circumcision.</p>\",\"PeriodicalId\":23416,\"journal\":{\"name\":\"Urology Journal\",\"volume\":\" \",\"pages\":\"424-428\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Urology Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.22037/uj.v20i.7788\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urology Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.22037/uj.v20i.7788","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的:评价一次性包皮环切器(DCSD)护系带技术在成年男性包皮环切术中的应用效果。材料与方法:确诊包皮过多的成年男性53例,采用环带保护技术行包皮环切术。评价术前、术后阴茎系带长度的主要测量指标。其他数据如水肿率、术中出血量、手术时间、术后疼痛、取钉时间、切口感染率、阴茎外观满意度评价。结果:两组患者术前、术后系带长度无明显差异。手术前后阴茎系带平均长度分别为2.25±0.36 cm和2.23±0.39 cm (P = 0.31)。系带长度保存率为100%。所有患者均未发生系带过度切除,术后无严重并发症发生。患者术后阴茎外观评价满意率为98.1%(52/53)。结论:系带保护技术简单易行,可帮助术者在DCSD包皮环切术中准确识别系带最远端位置,保留足够长度的系带。
Frenulum Protection Technique in Disposable Circumcision Suture Device for Adult Males.
Purpose: To evaluate the efficacy of frenulum protection technique of the disposable circumcision suture device (DCSD) in adult males.
Materials and methods: Atotal of 53 adult males were diagnosed with redundant prepuce and underwent circumcision with DCSD using frenulum protection technique. The main preoperative and postoperative measure of the length of penile frenulum was evaluated. Other data such as edema rate, intraoperative blood loss, operation time, postoperative pain, staple falling off time, incision infection rate, and evaluation of satisfaction rate with penis appearance were documented in the study.
Results: There was no significant difference in preoperative and postoperative frenulum length for each patient. The mean length of the penile frenulum before and after surgery was 2.25 ± 0.36 cm and 2.23 ± 0.39 cm, respectively (p = .31). The rate of frenulum length preservation was 100%. All the patients had no excessive resection of the frenulum and no serious complication happened after surgery. The satisfaction rate of postoperative penis appearance from patients' evaluation was 98.1% (52/53).
Conclusion: The frenulum protection technique was simple and operable, which could help the operator to accurately identify the most distal position of the frenulum and retain a sufficient length of frenulum during DCSD circumcision.
期刊介绍:
As the official journal of the Urology and Nephrology Research Center (UNRC) and the Iranian Urological Association (IUA), Urology Journal is a comprehensive digest of useful information on modern urology. Emphasis is on practical information that reflects the latest diagnostic and treatment techniques. Our objectives are to provide an exceptional source of current and clinically relevant research in the discipline of urology, to reflect the scientific work and progress of our colleagues, and to present the articles in a logical, timely, and concise format that meets the diverse needs of today’s urologist.
Urology Journal publishes manuscripts on urology and kidney transplantation, all of which undergo extensive peer review by recognized authorities in the field prior to their acceptance for publication. Accordingly, original articles, case reports, and letters to editor are encouraged.