H Heynemann, K P Richter, J Haerting, H J Holzhausen, J Baumann, K Jenderka, R Millner, B Langkopf
{"title":"[超声衰减在福尔马林固定睾丸组织中的频率函数]。","authors":"H Heynemann, K P Richter, J Haerting, H J Holzhausen, J Baumann, K Jenderka, R Millner, B Langkopf","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Measurements of the ultrasound attenuation were carried out in 10 normal testes and 20 pathologically changed testicular tissue biopsies in vitro after formalin fixation. The ultrasound attenuation as function of the frequency was recorded ultrasound-spectroscopically about the complete frequency spectrum of the ultrasound-broad range transformer (3-8 MHz). The frequency dependence of the attenuation behaviour differed in the 10 normal testes from the 20 pathologically changed biopsies by smaller values of the ultrasound attenuation coefficient a (linear regression analysis). The ultrasound attenuation in a characteristic measuring point allows the differentiation between normal and pathologically changed testicular tissue. The following comparison with the histologic evidences showed the correspondence of the results.</p>","PeriodicalId":77647,"journal":{"name":"Zeitschrift fur experimentelle Chirurgie, Transplantation, und kunstliche Organe : Organ der Sektion Experimentelle Chirurgie der Gesellschaft fur Chirurgie der DDR","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Ultrasound attenuation as a function of frequency in formalin fixed testicular tissue].\",\"authors\":\"H Heynemann, K P Richter, J Haerting, H J Holzhausen, J Baumann, K Jenderka, R Millner, B Langkopf\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Measurements of the ultrasound attenuation were carried out in 10 normal testes and 20 pathologically changed testicular tissue biopsies in vitro after formalin fixation. The ultrasound attenuation as function of the frequency was recorded ultrasound-spectroscopically about the complete frequency spectrum of the ultrasound-broad range transformer (3-8 MHz). The frequency dependence of the attenuation behaviour differed in the 10 normal testes from the 20 pathologically changed biopsies by smaller values of the ultrasound attenuation coefficient a (linear regression analysis). The ultrasound attenuation in a characteristic measuring point allows the differentiation between normal and pathologically changed testicular tissue. The following comparison with the histologic evidences showed the correspondence of the results.</p>\",\"PeriodicalId\":77647,\"journal\":{\"name\":\"Zeitschrift fur experimentelle Chirurgie, Transplantation, und kunstliche Organe : Organ der Sektion Experimentelle Chirurgie der Gesellschaft fur Chirurgie der DDR\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zeitschrift fur experimentelle Chirurgie, Transplantation, und kunstliche Organe : Organ der Sektion Experimentelle Chirurgie der Gesellschaft fur Chirurgie der DDR\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur experimentelle Chirurgie, Transplantation, und kunstliche Organe : Organ der Sektion Experimentelle Chirurgie der Gesellschaft fur Chirurgie der DDR","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Ultrasound attenuation as a function of frequency in formalin fixed testicular tissue].
Measurements of the ultrasound attenuation were carried out in 10 normal testes and 20 pathologically changed testicular tissue biopsies in vitro after formalin fixation. The ultrasound attenuation as function of the frequency was recorded ultrasound-spectroscopically about the complete frequency spectrum of the ultrasound-broad range transformer (3-8 MHz). The frequency dependence of the attenuation behaviour differed in the 10 normal testes from the 20 pathologically changed biopsies by smaller values of the ultrasound attenuation coefficient a (linear regression analysis). The ultrasound attenuation in a characteristic measuring point allows the differentiation between normal and pathologically changed testicular tissue. The following comparison with the histologic evidences showed the correspondence of the results.