{"title":"[苏制机械心脏瓣膜假体二尖瓣位置血流动力学特性比较]。","authors":"I N Gvakhariia,&nbsp;N A Chigogidze,&nbsp;Iu S Petrosian","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The article deals with hemodynamic evaluation of Soviet-made, and heart valve prostheses in late-term periods after operation for mitral valve replacement. Fourty-six patients were examined: a ball prosthesis was implanted in 21 patients (1st group), as disk prosthesis--in 15 patients (2nd group) and a prosthesis--in 10 patients (3rd group). A good clinical result of the operation was achieved in all patients, they were referred to functional class I and II. Catheterization of the left and right parts of the heart, left ventriculography, and test with dosed physical exertion were carried out. Loading was continued till cardiac output increased approximately by 60 per cent in 6 patients of the 1st group, 12 patients of the second group, and in all 10 patients of the 3rd group. The study showed that the prostheses do not yield to foreign models of heart valves in hemodynamic characteristics and cause a lower stenosing effect than the prostheses do. No essential differences were detected between the prostheses.</p>","PeriodicalId":73184,"journal":{"name":"Grudnaia khirurgiia (Moscow, Russia)","volume":" 6","pages":"37-41"},"PeriodicalIF":0.0000,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Comparative hemodynamic characteristics of Soviet-made mechanical heart valve prostheses in the mitral position].\",\"authors\":\"I N Gvakhariia,&nbsp;N A Chigogidze,&nbsp;Iu S Petrosian\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The article deals with hemodynamic evaluation of Soviet-made, and heart valve prostheses in late-term periods after operation for mitral valve replacement. Fourty-six patients were examined: a ball prosthesis was implanted in 21 patients (1st group), as disk prosthesis--in 15 patients (2nd group) and a prosthesis--in 10 patients (3rd group). A good clinical result of the operation was achieved in all patients, they were referred to functional class I and II. Catheterization of the left and right parts of the heart, left ventriculography, and test with dosed physical exertion were carried out. Loading was continued till cardiac output increased approximately by 60 per cent in 6 patients of the 1st group, 12 patients of the second group, and in all 10 patients of the 3rd group. The study showed that the prostheses do not yield to foreign models of heart valves in hemodynamic characteristics and cause a lower stenosing effect than the prostheses do. No essential differences were detected between the prostheses.</p>\",\"PeriodicalId\":73184,\"journal\":{\"name\":\"Grudnaia khirurgiia (Moscow, Russia)\",\"volume\":\" 6\",\"pages\":\"37-41\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Grudnaia khirurgiia (Moscow, Russia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Grudnaia khirurgiia (Moscow, Russia)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文对苏式人工心脏二尖瓣置换术后后期的血流动力学评价进行了研究。对46例患者进行检查:第一组21例植入球形假体,第二组15例植入盘状假体,第三组10例植入假体。所有患者均获得良好的临床手术效果,均被归为功能I级和II级。左、右心脏插管、左心室造影及大剂量体力消耗试验。在第一组的6名患者,第二组的12名患者和第三组的所有10名患者中,持续负荷直到心输出量增加约60%。研究表明,人工瓣膜在血流动力学特性上不屈服于国外模型的心脏瓣膜,其狭窄效应也比人工瓣膜小。假体之间没有发现本质差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Comparative hemodynamic characteristics of Soviet-made mechanical heart valve prostheses in the mitral position].

The article deals with hemodynamic evaluation of Soviet-made, and heart valve prostheses in late-term periods after operation for mitral valve replacement. Fourty-six patients were examined: a ball prosthesis was implanted in 21 patients (1st group), as disk prosthesis--in 15 patients (2nd group) and a prosthesis--in 10 patients (3rd group). A good clinical result of the operation was achieved in all patients, they were referred to functional class I and II. Catheterization of the left and right parts of the heart, left ventriculography, and test with dosed physical exertion were carried out. Loading was continued till cardiac output increased approximately by 60 per cent in 6 patients of the 1st group, 12 patients of the second group, and in all 10 patients of the 3rd group. The study showed that the prostheses do not yield to foreign models of heart valves in hemodynamic characteristics and cause a lower stenosing effect than the prostheses do. No essential differences were detected between the prostheses.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信