非离子型二聚体造影剂(iotrolan)在直接和间接动脉造影中的初步经验:一项随机、个体内双盲研究,60例患者。

B Hagen, B I Wenzel-Hora
{"title":"非离子型二聚体造影剂(iotrolan)在直接和间接动脉造影中的初步经验:一项随机、个体内双盲研究,60例患者。","authors":"B Hagen,&nbsp;B I Wenzel-Hora","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The new isotonic contrast medium iotrolan has been compared with iopromide in aortofemoral arteriography, selective femoral arteriography, and intravenous digital substraction angiography (DSA). In each case a crossover study design has been chosen with special emphasis on patient comfort. Despite problems in the interpretation of results due to a \"hangover\" effect in selective peripheral arteriography, it may be concluded: (1) Iotrolan causes significantly less discomfort, such as the feeling of heat and most likely also pain, than iopromide. However, one patient reported slight pain after the injection of iotrolan even when no previous injection of iopromide had been performed; (2) in intravenous DSA contrast appeared 1 to 2 seconds later in the region of interest after the injection of iotrolan compared with iopromide, probably due to the slightly higher viscosity of the former agent; (3) otherwise, no differences between the two agents have been observed. No cardiovascular or other kind of side effects occurred with the exception of one slight allergy-like reaction in 60 patients.</p>","PeriodicalId":75861,"journal":{"name":"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband","volume":"128 ","pages":"54-60"},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Initial experience with a nonionic, dimeric contrast medium (iotrolan) in direct and indirect arteriography: a randomized, intraindividual double-blind study in 60 patients.\",\"authors\":\"B Hagen,&nbsp;B I Wenzel-Hora\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The new isotonic contrast medium iotrolan has been compared with iopromide in aortofemoral arteriography, selective femoral arteriography, and intravenous digital substraction angiography (DSA). In each case a crossover study design has been chosen with special emphasis on patient comfort. Despite problems in the interpretation of results due to a \\\"hangover\\\" effect in selective peripheral arteriography, it may be concluded: (1) Iotrolan causes significantly less discomfort, such as the feeling of heat and most likely also pain, than iopromide. However, one patient reported slight pain after the injection of iotrolan even when no previous injection of iopromide had been performed; (2) in intravenous DSA contrast appeared 1 to 2 seconds later in the region of interest after the injection of iotrolan compared with iopromide, probably due to the slightly higher viscosity of the former agent; (3) otherwise, no differences between the two agents have been observed. No cardiovascular or other kind of side effects occurred with the exception of one slight allergy-like reaction in 60 patients.</p>\",\"PeriodicalId\":75861,\"journal\":{\"name\":\"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband\",\"volume\":\"128 \",\"pages\":\"54-60\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

新型等渗造影剂iotrolan与ioproide在股动脉造影、选择性股动脉造影和静脉数字减影血管造影(DSA)中的应用进行了比较。在每一个案例中,交叉研究设计的选择都特别强调患者的舒适度。尽管由于选择性外周动脉造影的“宿醉”效应在结果解释上存在问题,但可以得出以下结论:(1)Iotrolan引起的不适,如发热感,很可能还有疼痛感,明显少于ioproide。然而,一名患者在注射碘曲兰后报告轻微疼痛,即使之前没有注射过碘丙胺;(2)静脉DSA造影剂注射碘曲兰后感兴趣区出现时间较碘丙胺晚1 ~ 2秒,可能是由于前者黏度稍高所致;(3)其他情况下,未观察到两种药剂之间的差异。在60例患者中,除了一例轻微的过敏样反应外,没有发生心血管或其他类型的副作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Initial experience with a nonionic, dimeric contrast medium (iotrolan) in direct and indirect arteriography: a randomized, intraindividual double-blind study in 60 patients.

The new isotonic contrast medium iotrolan has been compared with iopromide in aortofemoral arteriography, selective femoral arteriography, and intravenous digital substraction angiography (DSA). In each case a crossover study design has been chosen with special emphasis on patient comfort. Despite problems in the interpretation of results due to a "hangover" effect in selective peripheral arteriography, it may be concluded: (1) Iotrolan causes significantly less discomfort, such as the feeling of heat and most likely also pain, than iopromide. However, one patient reported slight pain after the injection of iotrolan even when no previous injection of iopromide had been performed; (2) in intravenous DSA contrast appeared 1 to 2 seconds later in the region of interest after the injection of iotrolan compared with iopromide, probably due to the slightly higher viscosity of the former agent; (3) otherwise, no differences between the two agents have been observed. No cardiovascular or other kind of side effects occurred with the exception of one slight allergy-like reaction in 60 patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信