离子型和非离子型(异位聚亚胺钠和碘丙胺)x射线造影剂对血液流变学的影响。

E P Strecker, M Stengel, S Witte
{"title":"离子型和非离子型(异位聚亚胺钠和碘丙胺)x射线造影剂对血液流变学的影响。","authors":"E P Strecker,&nbsp;M Stengel,&nbsp;S Witte","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In two groups of ten patients each, an ionic and a nonionic contrast medium was injected intravenously, for digital subtraction angiography of the supra-aortic branches, to examine the influence of hemorrheologic properties. Afterward, blood samples were obtained through a central venous catheter and evaluated by a new instrument (oscillating capillary rheometer and densitometer). The viscous and elastic components of the complex blood viscosity and the hematocrit decreased after injection of ionic and nonionic contrast media. A statistically significant difference between the patient groups could not be found. The evaluated results describe an improvement of the hemorrheologic properties after contrast media injection.</p>","PeriodicalId":75861,"journal":{"name":"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband","volume":"128 ","pages":"24-7"},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of an ionic and a nonionic (sodium meglumine diatrizoate and iopromide) x-ray contrast medium of hemorrheology.\",\"authors\":\"E P Strecker,&nbsp;M Stengel,&nbsp;S Witte\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In two groups of ten patients each, an ionic and a nonionic contrast medium was injected intravenously, for digital subtraction angiography of the supra-aortic branches, to examine the influence of hemorrheologic properties. Afterward, blood samples were obtained through a central venous catheter and evaluated by a new instrument (oscillating capillary rheometer and densitometer). The viscous and elastic components of the complex blood viscosity and the hematocrit decreased after injection of ionic and nonionic contrast media. A statistically significant difference between the patient groups could not be found. The evaluated results describe an improvement of the hemorrheologic properties after contrast media injection.</p>\",\"PeriodicalId\":75861,\"journal\":{\"name\":\"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband\",\"volume\":\"128 \",\"pages\":\"24-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在两组各10名患者中,静脉注射离子和非离子造影剂,对主动脉上分支进行数字减影血管造影,以检查血液流变学特性的影响。随后,通过中心静脉导管采集血液样本,并通过一种新的仪器(振荡毛细管流变仪和密度计)进行评估。注射离子型和非离子型造影剂后,复合血液黏度和红细胞压积的黏性和弹性成分均有所下降。患者组间没有统计学上的显著差异。评价结果描述了注射造影剂后血液流变学特性的改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of an ionic and a nonionic (sodium meglumine diatrizoate and iopromide) x-ray contrast medium of hemorrheology.

In two groups of ten patients each, an ionic and a nonionic contrast medium was injected intravenously, for digital subtraction angiography of the supra-aortic branches, to examine the influence of hemorrheologic properties. Afterward, blood samples were obtained through a central venous catheter and evaluated by a new instrument (oscillating capillary rheometer and densitometer). The viscous and elastic components of the complex blood viscosity and the hematocrit decreased after injection of ionic and nonionic contrast media. A statistically significant difference between the patient groups could not be found. The evaluated results describe an improvement of the hemorrheologic properties after contrast media injection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信