{"title":"[1.5 T全身核磁共振扫描仪局部蛋白谱的再现性]。","authors":"M Pfeffer,&nbsp;W I Jung,&nbsp;O Lutz,&nbsp;K Müller,&nbsp;H Weissmann","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The CODEX method was employed for volume selective proton NMR spectroscopy with a whole body imager in order to control the quality of reproduction with phantoms. The spectral resolution and time stability during typical measuring times are almost better than 3.10(-8) and are usually sufficient for the requirements of high resolution in vivo proton spectroscopy.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 4","pages":"123-6"},"PeriodicalIF":0.0000,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Reproducibility of localized protein spectra with a 1.5 T whole body nuclear magnetic resonance scanner].\",\"authors\":\"M Pfeffer,&nbsp;W I Jung,&nbsp;O Lutz,&nbsp;K Müller,&nbsp;H Weissmann\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The CODEX method was employed for volume selective proton NMR spectroscopy with a whole body imager in order to control the quality of reproduction with phantoms. The spectral resolution and time stability during typical measuring times are almost better than 3.10(-8) and are usually sufficient for the requirements of high resolution in vivo proton spectroscopy.</p>\",\"PeriodicalId\":77527,\"journal\":{\"name\":\"Digitale Bilddiagnostik\",\"volume\":\"9 4\",\"pages\":\"123-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digitale Bilddiagnostik\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digitale Bilddiagnostik","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用CODEX方法对全身成像仪进行体积选择质子核磁共振波谱,以控制带影生殖的质量。在典型的测量时间内,光谱分辨率和时间稳定性几乎优于3.10(-8),通常足以满足体内高分辨率质子光谱的要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Reproducibility of localized protein spectra with a 1.5 T whole body nuclear magnetic resonance scanner].

The CODEX method was employed for volume selective proton NMR spectroscopy with a whole body imager in order to control the quality of reproduction with phantoms. The spectral resolution and time stability during typical measuring times are almost better than 3.10(-8) and are usually sufficient for the requirements of high resolution in vivo proton spectroscopy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信