视像目镜与交替棱镜盖法测量斜视的比较分析。

IF 3.7 3区 医学 Q1 OPHTHALMOLOGY
Asia-Pacific Journal of Ophthalmology Pub Date : 2023-11-01 Epub Date: 2023-11-17 DOI:10.1097/APO.0000000000000641
Mario Cantó-Cerdán, Antonio Martínez-Abad, Ana Siverio-Colomina, Rosa Díez, María A Amesty
{"title":"视像目镜与交替棱镜盖法测量斜视的比较分析。","authors":"Mario Cantó-Cerdán, Antonio Martínez-Abad, Ana Siverio-Colomina, Rosa Díez, María A Amesty","doi":"10.1097/APO.0000000000000641","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of the study was to compare distance vision measurements obtained with video oculography (VOG) and an alternate prism cover test (APCT).</p><p><strong>Design: </strong>Single-center, retrospective, and cross-sectional.</p><p><strong>Methods: </strong>Eighty-seven subjects with strabismus were included. All patients underwent an optometric examination. The measurement of strabismus in distance vision was performed with the best optical correction using the APCT and the VOG GazeLab. Subjects were divided according to the type of strabismus; 41 were esotropic and 46 were exotropic.</p><p><strong>Results: </strong>The general comparison of APCT and VOG showed a mean difference of 0.60±2.74 prism diopters (Δ), not observing statistical differences between both methods ( P =0.059) and presenting a correlation of 0.976 ( P <0.001). Using APCT, the mean amount of esotropia for the group was 18.31±11.64 Δ and that of exotropia was 19.62±8.80 Δ. Compared with the VOG, the mean value of esotropia for the group was 18.65±11.65 Δ and that of exotropia was 19.48±8.62 Δ. The means are statistically different for the esotropia group ( P =0.005) but not for the exotropia group ( P =0.318). There was a high direct correlation between the methods of measurement for both the esotropic ( R =0.980; P <0.001) and exotropic patients ( R =0.975; P <0.001). Bland-Altman analysis shows a mean difference of 1.37±2.76 Δ for the esotropia patients and 0.31±2.66 Δ for the exotropic patients, respectively.</p><p><strong>Conclusions: </strong>This study demonstrated comparable results in measuring strabismus between VOG and APTC for esotropia and exotropia, with an excellent correlation between both methods and good agreement, especially in subjects with exotropia.</p>","PeriodicalId":8594,"journal":{"name":"Asia-Pacific Journal of Ophthalmology","volume":" ","pages":"582-590"},"PeriodicalIF":3.7000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Analysis of Strabismus Measurement Using a Video Oculagraphy System and Alternate Prism Cover Test.\",\"authors\":\"Mario Cantó-Cerdán, Antonio Martínez-Abad, Ana Siverio-Colomina, Rosa Díez, María A Amesty\",\"doi\":\"10.1097/APO.0000000000000641\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of the study was to compare distance vision measurements obtained with video oculography (VOG) and an alternate prism cover test (APCT).</p><p><strong>Design: </strong>Single-center, retrospective, and cross-sectional.</p><p><strong>Methods: </strong>Eighty-seven subjects with strabismus were included. All patients underwent an optometric examination. The measurement of strabismus in distance vision was performed with the best optical correction using the APCT and the VOG GazeLab. Subjects were divided according to the type of strabismus; 41 were esotropic and 46 were exotropic.</p><p><strong>Results: </strong>The general comparison of APCT and VOG showed a mean difference of 0.60±2.74 prism diopters (Δ), not observing statistical differences between both methods ( P =0.059) and presenting a correlation of 0.976 ( P <0.001). Using APCT, the mean amount of esotropia for the group was 18.31±11.64 Δ and that of exotropia was 19.62±8.80 Δ. Compared with the VOG, the mean value of esotropia for the group was 18.65±11.65 Δ and that of exotropia was 19.48±8.62 Δ. The means are statistically different for the esotropia group ( P =0.005) but not for the exotropia group ( P =0.318). There was a high direct correlation between the methods of measurement for both the esotropic ( R =0.980; P <0.001) and exotropic patients ( R =0.975; P <0.001). Bland-Altman analysis shows a mean difference of 1.37±2.76 Δ for the esotropia patients and 0.31±2.66 Δ for the exotropic patients, respectively.</p><p><strong>Conclusions: </strong>This study demonstrated comparable results in measuring strabismus between VOG and APTC for esotropia and exotropia, with an excellent correlation between both methods and good agreement, especially in subjects with exotropia.</p>\",\"PeriodicalId\":8594,\"journal\":{\"name\":\"Asia-Pacific Journal of Ophthalmology\",\"volume\":\" \",\"pages\":\"582-590\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asia-Pacific Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/APO.0000000000000641\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/APO.0000000000000641","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是比较视频眼图(VOG)和交替棱镜盖测试(APCT)获得的远视力测量结果。设计:单中心,回顾性和横断面。方法:87例斜视患者。所有患者都进行了验光检查。使用APCT和VOG GazeLab进行最佳光学校正,测量远视斜视。根据斜视类型对受试者进行分组;内向型41只,外向型46只。结果:APCT与VOG的一般比较平均相差0.60±2.74棱镜屈光度(Δ),两种方法间无统计学差异(P=0.059),相关性为0.976 (P)。结论:本研究证明了VOG与APTC测量内斜视和外斜视的斜视结果具有可比性,两种方法之间具有良好的相关性,一致性较好,特别是在外斜视的受试者中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative Analysis of Strabismus Measurement Using a Video Oculagraphy System and Alternate Prism Cover Test.

Purpose: The aim of the study was to compare distance vision measurements obtained with video oculography (VOG) and an alternate prism cover test (APCT).

Design: Single-center, retrospective, and cross-sectional.

Methods: Eighty-seven subjects with strabismus were included. All patients underwent an optometric examination. The measurement of strabismus in distance vision was performed with the best optical correction using the APCT and the VOG GazeLab. Subjects were divided according to the type of strabismus; 41 were esotropic and 46 were exotropic.

Results: The general comparison of APCT and VOG showed a mean difference of 0.60±2.74 prism diopters (Δ), not observing statistical differences between both methods ( P =0.059) and presenting a correlation of 0.976 ( P <0.001). Using APCT, the mean amount of esotropia for the group was 18.31±11.64 Δ and that of exotropia was 19.62±8.80 Δ. Compared with the VOG, the mean value of esotropia for the group was 18.65±11.65 Δ and that of exotropia was 19.48±8.62 Δ. The means are statistically different for the esotropia group ( P =0.005) but not for the exotropia group ( P =0.318). There was a high direct correlation between the methods of measurement for both the esotropic ( R =0.980; P <0.001) and exotropic patients ( R =0.975; P <0.001). Bland-Altman analysis shows a mean difference of 1.37±2.76 Δ for the esotropia patients and 0.31±2.66 Δ for the exotropic patients, respectively.

Conclusions: This study demonstrated comparable results in measuring strabismus between VOG and APTC for esotropia and exotropia, with an excellent correlation between both methods and good agreement, especially in subjects with exotropia.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.10
自引率
18.20%
发文量
197
审稿时长
6 weeks
期刊介绍: The Asia-Pacific Journal of Ophthalmology, a bimonthly, peer-reviewed online scientific publication, is an official publication of the Asia-Pacific Academy of Ophthalmology (APAO), a supranational organization which is committed to research, training, learning, publication and knowledge and skill transfers in ophthalmology and visual sciences. The Asia-Pacific Journal of Ophthalmology welcomes review articles on currently hot topics, original, previously unpublished manuscripts describing clinical investigations, clinical observations and clinically relevant laboratory investigations, as well as .perspectives containing personal viewpoints on topics with broad interests. Editorials are published by invitation only. Case reports are generally not considered. The Asia-Pacific Journal of Ophthalmology covers 16 subspecialties and is freely circulated among individual members of the APAO’s member societies, which amounts to a potential readership of over 50,000.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信