尼日利亚三角洲州Ogorode热电厂热力参数审计及性能分析。

Sunday Iweriolor, Anwule Liberty, Blessing Josephine Ossai
{"title":"尼日利亚三角洲州Ogorode热电厂热力参数审计及性能分析。","authors":"Sunday Iweriolor, Anwule Liberty, Blessing Josephine Ossai","doi":"10.61448/jerisd12232","DOIUrl":null,"url":null,"abstract":"The exergy analysis of the Ogorode steam plant is presented. The aim was to determine and identify the magnitudes and locations of real exergy losses in order to improve plant efficiency. The exergy losses occurred in the various components of the steam plant, such as the boiler, economizer, turbine, super heater, condenser, pump, feed water heater, reheater, and air pre-heater, and these have been calculated using the concepts of availability or available exergy and irreversibility. The temperature and pressure of the plant's running conditions were combined to determine the process irreversibility (exergy losses) and the exergy efficiency of the plant. The exergy losses of the individual components of the plant show that the maximum exergy losses are in steam turbine operation one (STO ) and steam turbine operation two (STO ). STO and STO are 813 kJ/kg, 1 2 1 2 820 kJ/kg, 822 kJ/kg, and 815 kJ/kg that occurred in the turbine between 2019 and 2021, while the minimum exergy losses in STO and STO are 68 kJ/kg, 150 kJ/kg, 1 2 280 kJ/kg, and 276 kJ/kg that occurred in the boiler system between 2019 and 2021. There was a high energy efficiency of 82% and 80% in the superheater between 2019 and 2021, while 89% in the feed water heater and 73% in the superheater had the same duration. The efficiency of 15% and 21% were the minimum in the pump system between 2019 and 2021, while the turbine had a minimum of 20% and 27% from 2019 to 2021. The highest losses of exergy occurred in the turbine as a result of the irreversibility inherent in the turbine process, corroded turbine blades as a result of wet steam, and low energy delivered to the superheater tubes. It was concluded that the turbine inlet temperature should be increased, more energy delivered to the superheater should be increased, boiler pressure should be increased, and weak feed water heaters should be replaced for better performance of the thermal plant.","PeriodicalId":484452,"journal":{"name":"Journal Of Engineering Research Innovation And Scientific Development","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exergy Audit of Thermodynamic Parameters and Performance Analysis of Ogorode Thermal Power Plant in Delta State, Nigeria.\",\"authors\":\"Sunday Iweriolor, Anwule Liberty, Blessing Josephine Ossai\",\"doi\":\"10.61448/jerisd12232\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The exergy analysis of the Ogorode steam plant is presented. The aim was to determine and identify the magnitudes and locations of real exergy losses in order to improve plant efficiency. The exergy losses occurred in the various components of the steam plant, such as the boiler, economizer, turbine, super heater, condenser, pump, feed water heater, reheater, and air pre-heater, and these have been calculated using the concepts of availability or available exergy and irreversibility. The temperature and pressure of the plant's running conditions were combined to determine the process irreversibility (exergy losses) and the exergy efficiency of the plant. The exergy losses of the individual components of the plant show that the maximum exergy losses are in steam turbine operation one (STO ) and steam turbine operation two (STO ). STO and STO are 813 kJ/kg, 1 2 1 2 820 kJ/kg, 822 kJ/kg, and 815 kJ/kg that occurred in the turbine between 2019 and 2021, while the minimum exergy losses in STO and STO are 68 kJ/kg, 150 kJ/kg, 1 2 280 kJ/kg, and 276 kJ/kg that occurred in the boiler system between 2019 and 2021. There was a high energy efficiency of 82% and 80% in the superheater between 2019 and 2021, while 89% in the feed water heater and 73% in the superheater had the same duration. The efficiency of 15% and 21% were the minimum in the pump system between 2019 and 2021, while the turbine had a minimum of 20% and 27% from 2019 to 2021. The highest losses of exergy occurred in the turbine as a result of the irreversibility inherent in the turbine process, corroded turbine blades as a result of wet steam, and low energy delivered to the superheater tubes. It was concluded that the turbine inlet temperature should be increased, more energy delivered to the superheater should be increased, boiler pressure should be increased, and weak feed water heaters should be replaced for better performance of the thermal plant.\",\"PeriodicalId\":484452,\"journal\":{\"name\":\"Journal Of Engineering Research Innovation And Scientific Development\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal Of Engineering Research Innovation And Scientific Development\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.61448/jerisd12232\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal Of Engineering Research Innovation And Scientific Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.61448/jerisd12232","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Exergy Audit of Thermodynamic Parameters and Performance Analysis of Ogorode Thermal Power Plant in Delta State, Nigeria.
The exergy analysis of the Ogorode steam plant is presented. The aim was to determine and identify the magnitudes and locations of real exergy losses in order to improve plant efficiency. The exergy losses occurred in the various components of the steam plant, such as the boiler, economizer, turbine, super heater, condenser, pump, feed water heater, reheater, and air pre-heater, and these have been calculated using the concepts of availability or available exergy and irreversibility. The temperature and pressure of the plant's running conditions were combined to determine the process irreversibility (exergy losses) and the exergy efficiency of the plant. The exergy losses of the individual components of the plant show that the maximum exergy losses are in steam turbine operation one (STO ) and steam turbine operation two (STO ). STO and STO are 813 kJ/kg, 1 2 1 2 820 kJ/kg, 822 kJ/kg, and 815 kJ/kg that occurred in the turbine between 2019 and 2021, while the minimum exergy losses in STO and STO are 68 kJ/kg, 150 kJ/kg, 1 2 280 kJ/kg, and 276 kJ/kg that occurred in the boiler system between 2019 and 2021. There was a high energy efficiency of 82% and 80% in the superheater between 2019 and 2021, while 89% in the feed water heater and 73% in the superheater had the same duration. The efficiency of 15% and 21% were the minimum in the pump system between 2019 and 2021, while the turbine had a minimum of 20% and 27% from 2019 to 2021. The highest losses of exergy occurred in the turbine as a result of the irreversibility inherent in the turbine process, corroded turbine blades as a result of wet steam, and low energy delivered to the superheater tubes. It was concluded that the turbine inlet temperature should be increased, more energy delivered to the superheater should be increased, boiler pressure should be increased, and weak feed water heaters should be replaced for better performance of the thermal plant.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信