非延性开阔地面层钢筋混凝土框架倒塌能力评价

Emre AKIN, Emad KANAS
{"title":"非延性开阔地面层钢筋混凝土框架倒塌能力评价","authors":"Emre AKIN, Emad KANAS","doi":"10.31127/tuje.1071965","DOIUrl":null,"url":null,"abstract":"It is a well-known fact that the absence of infill walls at the ground story, which is termed as “open ground story” may lead to a soft-story deficiency, especially in the case of non-ductile buildings. The previous severe earthquakes have shown that catastrophic destruction may occur in such a condition. Therefore, the seismic assessment of open ground story reinforced frames, where the effects of infill walls are incorporated, is of vital importance. However, the effects of infill walls are generally disregarded or considered indirectly in the seismic assessment procedures of the codes. This may mislead the actual condition of the open ground story buildings at different performance levels. This study aims to assess a non-ductile reinforced concrete frame with an open ground story regarding the collapse prevention performance level. The pushover and incremental dynamic analyses results are evaluated following the code limitations for collapse prevention. The results demonstrate the measure of misleading caused by the ignorance of infills at the upper stories while applying these code limitations.","PeriodicalId":23377,"journal":{"name":"Turkish Journal of Engineering and Environmental Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Collapse capacity assessment of non-ductile open ground story reinforced concrete frame\",\"authors\":\"Emre AKIN, Emad KANAS\",\"doi\":\"10.31127/tuje.1071965\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is a well-known fact that the absence of infill walls at the ground story, which is termed as “open ground story” may lead to a soft-story deficiency, especially in the case of non-ductile buildings. The previous severe earthquakes have shown that catastrophic destruction may occur in such a condition. Therefore, the seismic assessment of open ground story reinforced frames, where the effects of infill walls are incorporated, is of vital importance. However, the effects of infill walls are generally disregarded or considered indirectly in the seismic assessment procedures of the codes. This may mislead the actual condition of the open ground story buildings at different performance levels. This study aims to assess a non-ductile reinforced concrete frame with an open ground story regarding the collapse prevention performance level. The pushover and incremental dynamic analyses results are evaluated following the code limitations for collapse prevention. The results demonstrate the measure of misleading caused by the ignorance of infills at the upper stories while applying these code limitations.\",\"PeriodicalId\":23377,\"journal\":{\"name\":\"Turkish Journal of Engineering and Environmental Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Engineering and Environmental Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31127/tuje.1071965\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Engineering and Environmental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31127/tuje.1071965","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

众所周知的事实是,在地面层(被称为“开放地面层”)缺乏填充墙可能导致软层不足,特别是在非延性建筑的情况下。以前的大地震表明,在这种情况下可能会发生灾难性的破坏。因此,考虑填充墙影响的露天层加筋框架的抗震评估是至关重要的。然而,在规范的地震评估过程中,填充墙的影响通常被忽略或间接考虑。这可能会误导不同性能水平的开放地面层建筑的实际情况。本研究旨在评估具有开放地面层的非延性钢筋混凝土框架的抗倒塌性能水平。根据防止倒塌的规范限制,对推覆和增量动态分析结果进行了评估。结果表明,在应用这些代码限制时,由于忽略上层的填充而造成的误导的度量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Collapse capacity assessment of non-ductile open ground story reinforced concrete frame
It is a well-known fact that the absence of infill walls at the ground story, which is termed as “open ground story” may lead to a soft-story deficiency, especially in the case of non-ductile buildings. The previous severe earthquakes have shown that catastrophic destruction may occur in such a condition. Therefore, the seismic assessment of open ground story reinforced frames, where the effects of infill walls are incorporated, is of vital importance. However, the effects of infill walls are generally disregarded or considered indirectly in the seismic assessment procedures of the codes. This may mislead the actual condition of the open ground story buildings at different performance levels. This study aims to assess a non-ductile reinforced concrete frame with an open ground story regarding the collapse prevention performance level. The pushover and incremental dynamic analyses results are evaluated following the code limitations for collapse prevention. The results demonstrate the measure of misleading caused by the ignorance of infills at the upper stories while applying these code limitations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信