{"title":"使用高光谱图像的衍射成像透镜的计算机模拟","authors":"S.I. Kharitonov, V.A. Fursov","doi":"10.18287/2412-6179-co-1274","DOIUrl":null,"url":null,"abstract":"We offer a computer technology for modeling a process of optical imaging with a diffractive imaging lens. The central idea of the technology is to evaluate the quality of the optical system by matching the input and output images against criteria adopted in image processing. For this purpose, same-resolution hyperspectral images are fed to the input and generated at the output. Thanks to the large number of spectral components, a fairly accurate reproduction of the effects associated with the dependence of the refractive index on the wavelength is ensured. To compare input and output images in terms of PSNR (peak signal-to-noise ratio), standard three-component RGB images are \"assembled\" using standard matching functions over the entire optical range. Results of the study of the dependence of the PSNR indicator on the main parameters of the optical system are given: focal length, linear aperture and the number of diffraction orders taken into account.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computer simulation of diffractive imaging lenses using hyperspectral images\",\"authors\":\"S.I. Kharitonov, V.A. Fursov\",\"doi\":\"10.18287/2412-6179-co-1274\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We offer a computer technology for modeling a process of optical imaging with a diffractive imaging lens. The central idea of the technology is to evaluate the quality of the optical system by matching the input and output images against criteria adopted in image processing. For this purpose, same-resolution hyperspectral images are fed to the input and generated at the output. Thanks to the large number of spectral components, a fairly accurate reproduction of the effects associated with the dependence of the refractive index on the wavelength is ensured. To compare input and output images in terms of PSNR (peak signal-to-noise ratio), standard three-component RGB images are \\\"assembled\\\" using standard matching functions over the entire optical range. Results of the study of the dependence of the PSNR indicator on the main parameters of the optical system are given: focal length, linear aperture and the number of diffraction orders taken into account.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18287/2412-6179-co-1274\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18287/2412-6179-co-1274","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Computer simulation of diffractive imaging lenses using hyperspectral images
We offer a computer technology for modeling a process of optical imaging with a diffractive imaging lens. The central idea of the technology is to evaluate the quality of the optical system by matching the input and output images against criteria adopted in image processing. For this purpose, same-resolution hyperspectral images are fed to the input and generated at the output. Thanks to the large number of spectral components, a fairly accurate reproduction of the effects associated with the dependence of the refractive index on the wavelength is ensured. To compare input and output images in terms of PSNR (peak signal-to-noise ratio), standard three-component RGB images are "assembled" using standard matching functions over the entire optical range. Results of the study of the dependence of the PSNR indicator on the main parameters of the optical system are given: focal length, linear aperture and the number of diffraction orders taken into account.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.