Wael A. Salah, Basem Abu Zneid, Amir Abu_Al_Aish, Mays Nofal
{"title":"医用智能便携式可控注射泵系统的研制","authors":"Wael A. Salah, Basem Abu Zneid, Amir Abu_Al_Aish, Mays Nofal","doi":"10.5614/j.eng.technol.sci.2023.55.3.7","DOIUrl":null,"url":null,"abstract":"Due to their efficiency and adaptability, automated applications are consistently gaining popularity around the world. Robotics and their applications as used in a variety of commonplace industries, such as medical applications, require a high level of precision and accuracy. This can be achieved by utilizing automated applications. In this work, the development and design of a regulated injection pump is detailed. The developed prototype is a type of robot that can be utilized in hospitals and other medical facilities. The proposed design is used to pump specific liquid volumes as specified by the user. During liquid pumping, both the fluid’s volume and velocity can be manipulated. Implementation of the proposed system required the development of a complete mechanical system and a controller. The proposed system was implemented successfully, and its operation was deemed satisfactory. According to the results, the accuracy of the system was also satisfactory. Using a flow sensor, the reference value and the measured value acquired from the designed device were compared. Compared to similar devices, the proposed system demonstrated exceptional precision, with an average error rate of less than 1.5%. The proposed model has the advantages of using a commercially available injection syringe and being significantly less expensive than similar devices on the market.","PeriodicalId":15689,"journal":{"name":"Journal of Engineering and Technological Sciences","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of Smart and Portable Controllable Syringe Pump System for Medical Applications\",\"authors\":\"Wael A. Salah, Basem Abu Zneid, Amir Abu_Al_Aish, Mays Nofal\",\"doi\":\"10.5614/j.eng.technol.sci.2023.55.3.7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to their efficiency and adaptability, automated applications are consistently gaining popularity around the world. Robotics and their applications as used in a variety of commonplace industries, such as medical applications, require a high level of precision and accuracy. This can be achieved by utilizing automated applications. In this work, the development and design of a regulated injection pump is detailed. The developed prototype is a type of robot that can be utilized in hospitals and other medical facilities. The proposed design is used to pump specific liquid volumes as specified by the user. During liquid pumping, both the fluid’s volume and velocity can be manipulated. Implementation of the proposed system required the development of a complete mechanical system and a controller. The proposed system was implemented successfully, and its operation was deemed satisfactory. According to the results, the accuracy of the system was also satisfactory. Using a flow sensor, the reference value and the measured value acquired from the designed device were compared. Compared to similar devices, the proposed system demonstrated exceptional precision, with an average error rate of less than 1.5%. The proposed model has the advantages of using a commercially available injection syringe and being significantly less expensive than similar devices on the market.\",\"PeriodicalId\":15689,\"journal\":{\"name\":\"Journal of Engineering and Technological Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Engineering and Technological Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5614/j.eng.technol.sci.2023.55.3.7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering and Technological Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5614/j.eng.technol.sci.2023.55.3.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
Development of Smart and Portable Controllable Syringe Pump System for Medical Applications
Due to their efficiency and adaptability, automated applications are consistently gaining popularity around the world. Robotics and their applications as used in a variety of commonplace industries, such as medical applications, require a high level of precision and accuracy. This can be achieved by utilizing automated applications. In this work, the development and design of a regulated injection pump is detailed. The developed prototype is a type of robot that can be utilized in hospitals and other medical facilities. The proposed design is used to pump specific liquid volumes as specified by the user. During liquid pumping, both the fluid’s volume and velocity can be manipulated. Implementation of the proposed system required the development of a complete mechanical system and a controller. The proposed system was implemented successfully, and its operation was deemed satisfactory. According to the results, the accuracy of the system was also satisfactory. Using a flow sensor, the reference value and the measured value acquired from the designed device were compared. Compared to similar devices, the proposed system demonstrated exceptional precision, with an average error rate of less than 1.5%. The proposed model has the advantages of using a commercially available injection syringe and being significantly less expensive than similar devices on the market.
期刊介绍:
Journal of Engineering and Technological Sciences welcomes full research articles in the area of Engineering Sciences from the following subject areas: Aerospace Engineering, Biotechnology, Chemical Engineering, Civil Engineering, Electrical Engineering, Engineering Physics, Environmental Engineering, Industrial Engineering, Information Engineering, Mechanical Engineering, Material Science and Engineering, Manufacturing Processes, Microelectronics, Mining Engineering, Petroleum Engineering, and other application of physical, biological, chemical and mathematical sciences in engineering. Authors are invited to submit articles that have not been published previously and are not under consideration elsewhere.