二次绕组非隔离三相变压器式SFCL故障限流操作分析

Tae-Hee Han, Seok-Cheol Ko, Sung-Hun Lim
{"title":"二次绕组非隔离三相变压器式SFCL故障限流操作分析","authors":"Tae-Hee Han, Seok-Cheol Ko, Sung-Hun Lim","doi":"10.5207/jieie.2023.37.5.062","DOIUrl":null,"url":null,"abstract":"Three-phase transformer type superconducting fault current limiter(SFCL) using secondary windings with non-isolation, which consisted of three-phase transformer windings wound on three legs of E-I iron core and three superconducting modules(SCMs), were suggested and its fault current limiting operations according to ground-fault types were analyzed. To verify the effective operation of three-phase transformer type SFCL using secondary windings with non-isolation, the unsymmetrical ground and the symmetrical ground faults were applied into three-phase power simulated system with the suggested SFCL. From the analysis on the experiment, three-phase transformer type SFCL using secondary windings with non-isolation showed lower power burden of three SCMs compared to the SFCL using secondary winding with isolation, especially in case of an unsymmetrical ground fault occurrence.","PeriodicalId":488820,"journal":{"name":"Journal of The Korean Institute of Illuminating and Electrical Installation Engineers","volume":"79 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis on Fault Current Limiting Operations of Three-Phase Transformer Type SFCL Using Secondary Windings with Non-Isolation\",\"authors\":\"Tae-Hee Han, Seok-Cheol Ko, Sung-Hun Lim\",\"doi\":\"10.5207/jieie.2023.37.5.062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Three-phase transformer type superconducting fault current limiter(SFCL) using secondary windings with non-isolation, which consisted of three-phase transformer windings wound on three legs of E-I iron core and three superconducting modules(SCMs), were suggested and its fault current limiting operations according to ground-fault types were analyzed. To verify the effective operation of three-phase transformer type SFCL using secondary windings with non-isolation, the unsymmetrical ground and the symmetrical ground faults were applied into three-phase power simulated system with the suggested SFCL. From the analysis on the experiment, three-phase transformer type SFCL using secondary windings with non-isolation showed lower power burden of three SCMs compared to the SFCL using secondary winding with isolation, especially in case of an unsymmetrical ground fault occurrence.\",\"PeriodicalId\":488820,\"journal\":{\"name\":\"Journal of The Korean Institute of Illuminating and Electrical Installation Engineers\",\"volume\":\"79 \",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Korean Institute of Illuminating and Electrical Installation Engineers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5207/jieie.2023.37.5.062\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Korean Institute of Illuminating and Electrical Installation Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5207/jieie.2023.37.5.062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种采用非隔离二次绕组的三相变压器型超导故障限流器(SFCL),由三相变压器绕组绕在E-I铁芯的三支腿上与三个超导模块(scm)组成,并根据接地故障类型分析了其故障限流操作。为了验证采用非隔离二次绕组的三相变压器式SFCL的有效运行,将非对称接地和对称接地故障应用于三相电力仿真系统。从实验分析来看,采用二次绕组不隔离的三相变压器型SFCL与采用二次绕组带隔离的SFCL相比,三台单片机的功率负荷更低,特别是在发生不对称接地故障时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis on Fault Current Limiting Operations of Three-Phase Transformer Type SFCL Using Secondary Windings with Non-Isolation
Three-phase transformer type superconducting fault current limiter(SFCL) using secondary windings with non-isolation, which consisted of three-phase transformer windings wound on three legs of E-I iron core and three superconducting modules(SCMs), were suggested and its fault current limiting operations according to ground-fault types were analyzed. To verify the effective operation of three-phase transformer type SFCL using secondary windings with non-isolation, the unsymmetrical ground and the symmetrical ground faults were applied into three-phase power simulated system with the suggested SFCL. From the analysis on the experiment, three-phase transformer type SFCL using secondary windings with non-isolation showed lower power burden of three SCMs compared to the SFCL using secondary winding with isolation, especially in case of an unsymmetrical ground fault occurrence.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信