Michael Swikehardt , Janice Newsome , Matthew Macey , Peter Park , Rajendran Vilvendhan , Arif Kamil , Zachary Bercu , Sebastian Flacke MD, PhD
{"title":"介入放射学中的经皮机器人技术","authors":"Michael Swikehardt , Janice Newsome , Matthew Macey , Peter Park , Rajendran Vilvendhan , Arif Kamil , Zachary Bercu , Sebastian Flacke MD, PhD","doi":"10.1016/j.tvir.2023.100917","DOIUrl":null,"url":null,"abstract":"<div><p>The accuracy of the robotic device not only relies on a reproducible needle advancement, but also on the possibility to correct target movement at chosen checkpoints and to deviate from a linear to a nonlinear trajectory. We report our experience in using the robotic device for the insertion of trocar needles in CT guided procedures. The majority of procedures were targeted organ biopsies in the chest abdomen or pelvis. The accuracy of needle placement after target adjustments did not significantly differ from those patients where a linear trajectory could be used. The steering capabilities of the robot allow correction of target movement of the fly.</p></div>","PeriodicalId":51613,"journal":{"name":"Techniques in Vascular and Interventional Radiology","volume":"26 3","pages":"Article 100917"},"PeriodicalIF":1.4000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Percutaneous Robotics in Interventional Radiology\",\"authors\":\"Michael Swikehardt , Janice Newsome , Matthew Macey , Peter Park , Rajendran Vilvendhan , Arif Kamil , Zachary Bercu , Sebastian Flacke MD, PhD\",\"doi\":\"10.1016/j.tvir.2023.100917\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The accuracy of the robotic device not only relies on a reproducible needle advancement, but also on the possibility to correct target movement at chosen checkpoints and to deviate from a linear to a nonlinear trajectory. We report our experience in using the robotic device for the insertion of trocar needles in CT guided procedures. The majority of procedures were targeted organ biopsies in the chest abdomen or pelvis. The accuracy of needle placement after target adjustments did not significantly differ from those patients where a linear trajectory could be used. The steering capabilities of the robot allow correction of target movement of the fly.</p></div>\",\"PeriodicalId\":51613,\"journal\":{\"name\":\"Techniques in Vascular and Interventional Radiology\",\"volume\":\"26 3\",\"pages\":\"Article 100917\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Techniques in Vascular and Interventional Radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1089251623000331\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Vascular and Interventional Radiology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1089251623000331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
The accuracy of the robotic device not only relies on a reproducible needle advancement, but also on the possibility to correct target movement at chosen checkpoints and to deviate from a linear to a nonlinear trajectory. We report our experience in using the robotic device for the insertion of trocar needles in CT guided procedures. The majority of procedures were targeted organ biopsies in the chest abdomen or pelvis. The accuracy of needle placement after target adjustments did not significantly differ from those patients where a linear trajectory could be used. The steering capabilities of the robot allow correction of target movement of the fly.
期刊介绍:
Interventional radiology is an area of clinical diagnosis and management that is highly technique-oriented. Therefore, the format of this quarterly journal, which combines the visual impact of an atlas with the currency of a journal, lends itself perfectly to presenting the topics. Each issue is guest edited by a leader in the field and is focused on a single clinical technique or problem. The presentation is enhanced by superb illustrations and descriptive narrative outlining the steps of a particular procedure. Interventional radiologists, neuroradiologists, vascular surgeons and neurosurgeons will find this a useful addition to the clinical literature.