{"title":"CE-C4D法同时测定苄基二甲基辛基氯化铵和苄基二甲基十二烷基氯化铵","authors":"Chien Dinh Viet, Anh Huong Nguyen Thi","doi":"10.47866/2615-9252/vjfc.4115","DOIUrl":null,"url":null,"abstract":"Benzyldimethyloctylammonium chloride (BAC-C8) and Benzyldimethyldodecyl ammonium chloride (BAC-C12) are bactericidal surfactants which widely used in the pharmaceutical industry as anti-microbial disinfectants in skin antiseptic solution. According to current international regulations, the standard of finished antiseptic solution must have regulations on the limit of preservatives when used in the formulation. In this study, simultaneous determination of BAC-C8 and BAC-C12 was performed by capillary electrophoresis using capacitively coupled contactless conductivity detection (CE-C4D) with analytical conditions including: fused silica capillary (50 µm ID.) with effective length of 40 cm, background electrolyte solution of 100 mM acetic acid (Ace) added 30% acetonitril (ACN); hydrodynamic sample injection at height of 10 cm in 20 s; separation voltage of +15 kV. The detection limit of BAC-C8 and BAC-C12 were 1.5 mg/L and 3.5 mg/L, respectively. This method has been applied to determine the content of BAC-C8 and BACC12 in the disinfectant solution samples.","PeriodicalId":498772,"journal":{"name":"Tạp chí Kiểm nghiệm và An toàn thực phẩm","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous determination of benzyldimethyloctylammonium chloride and benzyldimethyldodecylammonium chloride by CE-C4D\",\"authors\":\"Chien Dinh Viet, Anh Huong Nguyen Thi\",\"doi\":\"10.47866/2615-9252/vjfc.4115\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Benzyldimethyloctylammonium chloride (BAC-C8) and Benzyldimethyldodecyl ammonium chloride (BAC-C12) are bactericidal surfactants which widely used in the pharmaceutical industry as anti-microbial disinfectants in skin antiseptic solution. According to current international regulations, the standard of finished antiseptic solution must have regulations on the limit of preservatives when used in the formulation. In this study, simultaneous determination of BAC-C8 and BAC-C12 was performed by capillary electrophoresis using capacitively coupled contactless conductivity detection (CE-C4D) with analytical conditions including: fused silica capillary (50 µm ID.) with effective length of 40 cm, background electrolyte solution of 100 mM acetic acid (Ace) added 30% acetonitril (ACN); hydrodynamic sample injection at height of 10 cm in 20 s; separation voltage of +15 kV. The detection limit of BAC-C8 and BAC-C12 were 1.5 mg/L and 3.5 mg/L, respectively. This method has been applied to determine the content of BAC-C8 and BACC12 in the disinfectant solution samples.\",\"PeriodicalId\":498772,\"journal\":{\"name\":\"Tạp chí Kiểm nghiệm và An toàn thực phẩm\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tạp chí Kiểm nghiệm và An toàn thực phẩm\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47866/2615-9252/vjfc.4115\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tạp chí Kiểm nghiệm và An toàn thực phẩm","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47866/2615-9252/vjfc.4115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simultaneous determination of benzyldimethyloctylammonium chloride and benzyldimethyldodecylammonium chloride by CE-C4D
Benzyldimethyloctylammonium chloride (BAC-C8) and Benzyldimethyldodecyl ammonium chloride (BAC-C12) are bactericidal surfactants which widely used in the pharmaceutical industry as anti-microbial disinfectants in skin antiseptic solution. According to current international regulations, the standard of finished antiseptic solution must have regulations on the limit of preservatives when used in the formulation. In this study, simultaneous determination of BAC-C8 and BAC-C12 was performed by capillary electrophoresis using capacitively coupled contactless conductivity detection (CE-C4D) with analytical conditions including: fused silica capillary (50 µm ID.) with effective length of 40 cm, background electrolyte solution of 100 mM acetic acid (Ace) added 30% acetonitril (ACN); hydrodynamic sample injection at height of 10 cm in 20 s; separation voltage of +15 kV. The detection limit of BAC-C8 and BAC-C12 were 1.5 mg/L and 3.5 mg/L, respectively. This method has been applied to determine the content of BAC-C8 and BACC12 in the disinfectant solution samples.