{"title":"用暴露温度评价耐火涂料的性能","authors":"Hyun Kang, Heung Youl Kim, Oh Sang Kweon","doi":"10.7731/kifse.7db87c58","DOIUrl":null,"url":null,"abstract":"In Korea, industrial complexes for manufacturing and producing various products have been established in the region. Owing to their rapid development and ease of management, most industrial complexes are composed of steel-structured buildings, and only few buildings are reinforced concrete structures. Steel-structure buildings are generally known to have relatively low fire resistance depending on their material characteristics, which necessitates additional fire resistance reinforcement procedures to ensure structural safety. In this study, we experimentally evaluated the behavioral characteristics according to the exposure temperature of intumescent paint, which is a fire-resistant reinforcement material applied in various steel structures (including industrial complexes), to use it as a database for the diagnostic evaluation of fire-damaged steel structures.","PeriodicalId":6687,"journal":{"name":"2019 9th International Conference on Fire Science and Fire Protection Engineering (ICFSFPE)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Behavioral Characteristics of the Fire Resistant Paint by Exposure Temperature\",\"authors\":\"Hyun Kang, Heung Youl Kim, Oh Sang Kweon\",\"doi\":\"10.7731/kifse.7db87c58\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In Korea, industrial complexes for manufacturing and producing various products have been established in the region. Owing to their rapid development and ease of management, most industrial complexes are composed of steel-structured buildings, and only few buildings are reinforced concrete structures. Steel-structure buildings are generally known to have relatively low fire resistance depending on their material characteristics, which necessitates additional fire resistance reinforcement procedures to ensure structural safety. In this study, we experimentally evaluated the behavioral characteristics according to the exposure temperature of intumescent paint, which is a fire-resistant reinforcement material applied in various steel structures (including industrial complexes), to use it as a database for the diagnostic evaluation of fire-damaged steel structures.\",\"PeriodicalId\":6687,\"journal\":{\"name\":\"2019 9th International Conference on Fire Science and Fire Protection Engineering (ICFSFPE)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 9th International Conference on Fire Science and Fire Protection Engineering (ICFSFPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7731/kifse.7db87c58\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 9th International Conference on Fire Science and Fire Protection Engineering (ICFSFPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7731/kifse.7db87c58","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of Behavioral Characteristics of the Fire Resistant Paint by Exposure Temperature
In Korea, industrial complexes for manufacturing and producing various products have been established in the region. Owing to their rapid development and ease of management, most industrial complexes are composed of steel-structured buildings, and only few buildings are reinforced concrete structures. Steel-structure buildings are generally known to have relatively low fire resistance depending on their material characteristics, which necessitates additional fire resistance reinforcement procedures to ensure structural safety. In this study, we experimentally evaluated the behavioral characteristics according to the exposure temperature of intumescent paint, which is a fire-resistant reinforcement material applied in various steel structures (including industrial complexes), to use it as a database for the diagnostic evaluation of fire-damaged steel structures.