Paulius Vestfal, Jurgita Černeckienė, Lina Šeduikytė
{"title":"高空间建筑采暖系统解决方案对建筑节能的影响分析","authors":"Paulius Vestfal, Jurgita Černeckienė, Lina Šeduikytė","doi":"10.5755/j01.sace.33.2.34305","DOIUrl":null,"url":null,"abstract":"The existence of stratification in high-ceiling buildings is real, but not visible or easy noticeable by humans. For field measurements, the Prayer House – The Kaunas Basilica of the Resurrection of Christ, located in Kaunas, Lithuania, was chosen, in which the temperature distribution at different heights (6 m, 8 m, 10 m, 12 m, 14 m, 16 m and 18 m) during the heating season was observed. The Basilica had radiant heaters installed at 5 m height. According to the plan of the Prayer House, CFD model was created, and the temperature distribution of the different heating (radiant heating and floor heating) systems were compared. The IDA-ICE modelling of energy consumption was conducted using the CFD results as a basis, and the economic analysis was performed based on the obtained results. The study confirmed the existence of stratification in high-ceiling buildings.","PeriodicalId":36795,"journal":{"name":"Journal of Sustainable Architecture and Civil Engineering","volume":"60 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of the Impact of High-Space Building Heating System Solutions on Building Energy Efficiency\",\"authors\":\"Paulius Vestfal, Jurgita Černeckienė, Lina Šeduikytė\",\"doi\":\"10.5755/j01.sace.33.2.34305\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The existence of stratification in high-ceiling buildings is real, but not visible or easy noticeable by humans. For field measurements, the Prayer House – The Kaunas Basilica of the Resurrection of Christ, located in Kaunas, Lithuania, was chosen, in which the temperature distribution at different heights (6 m, 8 m, 10 m, 12 m, 14 m, 16 m and 18 m) during the heating season was observed. The Basilica had radiant heaters installed at 5 m height. According to the plan of the Prayer House, CFD model was created, and the temperature distribution of the different heating (radiant heating and floor heating) systems were compared. The IDA-ICE modelling of energy consumption was conducted using the CFD results as a basis, and the economic analysis was performed based on the obtained results. The study confirmed the existence of stratification in high-ceiling buildings.\",\"PeriodicalId\":36795,\"journal\":{\"name\":\"Journal of Sustainable Architecture and Civil Engineering\",\"volume\":\"60 6\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sustainable Architecture and Civil Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5755/j01.sace.33.2.34305\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sustainable Architecture and Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5755/j01.sace.33.2.34305","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
Analysis of the Impact of High-Space Building Heating System Solutions on Building Energy Efficiency
The existence of stratification in high-ceiling buildings is real, but not visible or easy noticeable by humans. For field measurements, the Prayer House – The Kaunas Basilica of the Resurrection of Christ, located in Kaunas, Lithuania, was chosen, in which the temperature distribution at different heights (6 m, 8 m, 10 m, 12 m, 14 m, 16 m and 18 m) during the heating season was observed. The Basilica had radiant heaters installed at 5 m height. According to the plan of the Prayer House, CFD model was created, and the temperature distribution of the different heating (radiant heating and floor heating) systems were compared. The IDA-ICE modelling of energy consumption was conducted using the CFD results as a basis, and the economic analysis was performed based on the obtained results. The study confirmed the existence of stratification in high-ceiling buildings.