{"title":"对Muhammadiyah Purwokerto大学环境中的ch AR Fachruddin的避雷针保护系统进行评估","authors":"Winarso Winarso, Zyon Ridho","doi":"10.30595/pspfs.v6i.859","DOIUrl":null,"url":null,"abstract":"Universitas Muhammadiyah Purwokerto has numerous buildings, including the rectorate and the 55.27-meter-tall K.H. A.R. Fachruddin building, that could be struck by lightning and as a result, it require an efficient lightning arrester system (SPP). This study aims to evaluate the building's lightning safety level in compliance with SNI 03-7015-2004, the General Regulations for Lightning Protection Installation (PUIPP), and the building's lightning arrester system's state. Direct measurements of building structures, lightning arrester system components, lightning arrester conditions, and soil resistance are employed to collect research data using the observational approach. The study calculates the degree of protection in structures in accordance with the General Regulations for Lightning Protection Installation (PUIPP) standards and determines the value of the protection range using SNI 03-7015-2004. Both the KH AR Fachruddin building and the rectorate building have an R index of 14, which means that they both desperately need an efficient lightning arrester. The Rector building's system is only 75% effective, compared to 91% in the KH AR Fachruddin building.","PeriodicalId":165554,"journal":{"name":"Proceedings Series on Physical & Formal Sciences","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluasi Sistem Proteksi Penangkap Petir pada Gedung Rektorat dan Gedung KH AR Fachruddin di Lingkungan Universitas Muhammadiyah Purwokerto\",\"authors\":\"Winarso Winarso, Zyon Ridho\",\"doi\":\"10.30595/pspfs.v6i.859\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Universitas Muhammadiyah Purwokerto has numerous buildings, including the rectorate and the 55.27-meter-tall K.H. A.R. Fachruddin building, that could be struck by lightning and as a result, it require an efficient lightning arrester system (SPP). This study aims to evaluate the building's lightning safety level in compliance with SNI 03-7015-2004, the General Regulations for Lightning Protection Installation (PUIPP), and the building's lightning arrester system's state. Direct measurements of building structures, lightning arrester system components, lightning arrester conditions, and soil resistance are employed to collect research data using the observational approach. The study calculates the degree of protection in structures in accordance with the General Regulations for Lightning Protection Installation (PUIPP) standards and determines the value of the protection range using SNI 03-7015-2004. Both the KH AR Fachruddin building and the rectorate building have an R index of 14, which means that they both desperately need an efficient lightning arrester. The Rector building's system is only 75% effective, compared to 91% in the KH AR Fachruddin building.\",\"PeriodicalId\":165554,\"journal\":{\"name\":\"Proceedings Series on Physical & Formal Sciences\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings Series on Physical & Formal Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30595/pspfs.v6i.859\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Series on Physical & Formal Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30595/pspfs.v6i.859","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
Universitas Muhammadiyah Purwokerto有许多建筑,包括校长和55.27米高的k.h.a.r. Fachruddin大楼,这些建筑可能会被闪电击中,因此,它需要一个有效的避雷器系统(SPP)。本研究旨在根据SNI 03-7015-2004、防雷装置通用规定(PUIPP)和建筑物避雷器系统状态评估建筑物的防雷安全水平。采用观测方法直接测量建筑结构、避雷器系统组件、避雷器条件和土壤阻力来收集研究数据。本研究按照《防雷装置通用规程》(PUIPP)标准计算结构的防护程度,采用SNI 03-7015-2004确定防护范围的数值。KH AR Fachruddin大楼和校长大楼的R指数都是14,这意味着它们都迫切需要一个有效的避雷器。校长大楼的系统效率只有75%,而KH AR法克鲁丁大楼的效率为91%。
Evaluasi Sistem Proteksi Penangkap Petir pada Gedung Rektorat dan Gedung KH AR Fachruddin di Lingkungan Universitas Muhammadiyah Purwokerto
Universitas Muhammadiyah Purwokerto has numerous buildings, including the rectorate and the 55.27-meter-tall K.H. A.R. Fachruddin building, that could be struck by lightning and as a result, it require an efficient lightning arrester system (SPP). This study aims to evaluate the building's lightning safety level in compliance with SNI 03-7015-2004, the General Regulations for Lightning Protection Installation (PUIPP), and the building's lightning arrester system's state. Direct measurements of building structures, lightning arrester system components, lightning arrester conditions, and soil resistance are employed to collect research data using the observational approach. The study calculates the degree of protection in structures in accordance with the General Regulations for Lightning Protection Installation (PUIPP) standards and determines the value of the protection range using SNI 03-7015-2004. Both the KH AR Fachruddin building and the rectorate building have an R index of 14, which means that they both desperately need an efficient lightning arrester. The Rector building's system is only 75% effective, compared to 91% in the KH AR Fachruddin building.