一种新型低成本、可穿戴式运动监测仪在实验室环境中的有效性

Jacob Barkley, Andrew Newton, Ellen Glickman
{"title":"一种新型低成本、可穿戴式运动监测仪在实验室环境中的有效性","authors":"Jacob Barkley, Andrew Newton, Ellen Glickman","doi":"10.53520/rdhs2023.10469","DOIUrl":null,"url":null,"abstract":"Introduction: Wearable physical activity monitors are popular and may provide a more accurate data than subjective methods. The present study assessed the validity of a novel, low-cost wearable physical activity monitor (Movband 3) relative to established measures. Methods: Participants (N = 19) completed four treadmill stages (1.5, 3.0, 4.0, 6.0 MPH) while wearing the Movband 3 and the validated Actigraph GT1M monitor. Oxygen consumption (VO2 ml/kg/min) and heart rate (beats/min) were recorded. The relationship between Movband data and established measures was assessed via Pearson’s correlations. Tests of agreement were performed for actual and Movband miles traveled. Results: There were large, positive, significant (p < 0.001) effect sizes for the associations between Movband counts and Actigraph counts (r = 0.72), VO2 (r = 0.59), and heart rate (r = 0.63). There was also a large, positive, significant (p < 0.001) association between actual and Movband miles (r = 0.97). However, the difference (Δ) between Movband and actual miles was greater than a null hypothesis of zero (∆ = 0.77 ± 0.45 miles or 31.8%, t = 7.4, p < 0.001). Conclusion: While there was evidence to support the validity of the Movband 3 for the assessment of physical activity intensity this device did not provide an accurate measure of miles traveled.","PeriodicalId":74674,"journal":{"name":"Research Directs in health sciences","volume":"210 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Validity of a Novel Low-Cost, Wearable Physical Activity Monitor in a Laboratory Setting\",\"authors\":\"Jacob Barkley, Andrew Newton, Ellen Glickman\",\"doi\":\"10.53520/rdhs2023.10469\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Wearable physical activity monitors are popular and may provide a more accurate data than subjective methods. The present study assessed the validity of a novel, low-cost wearable physical activity monitor (Movband 3) relative to established measures. Methods: Participants (N = 19) completed four treadmill stages (1.5, 3.0, 4.0, 6.0 MPH) while wearing the Movband 3 and the validated Actigraph GT1M monitor. Oxygen consumption (VO2 ml/kg/min) and heart rate (beats/min) were recorded. The relationship between Movband data and established measures was assessed via Pearson’s correlations. Tests of agreement were performed for actual and Movband miles traveled. Results: There were large, positive, significant (p < 0.001) effect sizes for the associations between Movband counts and Actigraph counts (r = 0.72), VO2 (r = 0.59), and heart rate (r = 0.63). There was also a large, positive, significant (p < 0.001) association between actual and Movband miles (r = 0.97). However, the difference (Δ) between Movband and actual miles was greater than a null hypothesis of zero (∆ = 0.77 ± 0.45 miles or 31.8%, t = 7.4, p < 0.001). Conclusion: While there was evidence to support the validity of the Movband 3 for the assessment of physical activity intensity this device did not provide an accurate measure of miles traveled.\",\"PeriodicalId\":74674,\"journal\":{\"name\":\"Research Directs in health sciences\",\"volume\":\"210 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research Directs in health sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53520/rdhs2023.10469\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research Directs in health sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53520/rdhs2023.10469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

简介:可穿戴式身体活动监测仪很受欢迎,它可以提供比主观方法更准确的数据。本研究评估了一种新型、低成本的可穿戴身体活动监测器(Movband 3)相对于现有测量方法的有效性。方法:参与者(N = 19)在佩戴Movband 3和经过验证的Actigraph GT1M监测器的情况下完成了四个跑步机阶段(1.5,3.0,4.0,6.0 MPH)。记录耗氧量(VO2 ml/kg/min)和心率(次/min)。通过Pearson相关性评估Movband数据与既定测量之间的关系。对实际里程和移动里程进行了一致性测试。结果:有较大、阳性、显著(p <0.001)动带计数和活动图计数(r = 0.72)、摄氧量(r = 0.59)和心率(r = 0.63)之间关联的效应大小。还有一个巨大的、积极的、显著的(p <0.001)实际里程数和移动带里程之间的关联(r = 0.97)。然而,Movband与实际里程之间的差异(Δ)大于零的零假设(∆= 0.77±0.45英里或31.8%,t = 7.4, p <0.001)。结论:虽然有证据支持Movband 3在评估身体活动强度方面的有效性,但该设备并没有提供准确的旅行里程测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Validity of a Novel Low-Cost, Wearable Physical Activity Monitor in a Laboratory Setting
Introduction: Wearable physical activity monitors are popular and may provide a more accurate data than subjective methods. The present study assessed the validity of a novel, low-cost wearable physical activity monitor (Movband 3) relative to established measures. Methods: Participants (N = 19) completed four treadmill stages (1.5, 3.0, 4.0, 6.0 MPH) while wearing the Movband 3 and the validated Actigraph GT1M monitor. Oxygen consumption (VO2 ml/kg/min) and heart rate (beats/min) were recorded. The relationship between Movband data and established measures was assessed via Pearson’s correlations. Tests of agreement were performed for actual and Movband miles traveled. Results: There were large, positive, significant (p < 0.001) effect sizes for the associations between Movband counts and Actigraph counts (r = 0.72), VO2 (r = 0.59), and heart rate (r = 0.63). There was also a large, positive, significant (p < 0.001) association between actual and Movband miles (r = 0.97). However, the difference (Δ) between Movband and actual miles was greater than a null hypothesis of zero (∆ = 0.77 ± 0.45 miles or 31.8%, t = 7.4, p < 0.001). Conclusion: While there was evidence to support the validity of the Movband 3 for the assessment of physical activity intensity this device did not provide an accurate measure of miles traveled.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信