{"title":"基于多级滤波的心电信号预处理","authors":"Mohammed Waheed","doi":"10.29292/jics.v18i2.698","DOIUrl":null,"url":null,"abstract":"In this paper, a new approach was adopted in order to remove the artifacts present in the raw ECG signal. To realizing this process a multiple types of filters for a variety of types of noises have been applied to obtain the lowest possible noise. Initially, the ECG signal was filtered from the electromyography signal, and then the filtered signal was passed again on another filter for the purpose of removing its drift from the baseline. The effectiveness of the suggested approach has been assessed in comparison to the conventional ECG signal. Results of this study showed significantly less signaling noise than was present in the conventional signal. Overall, the signal to noise ratio and the mean square error of the filtered ECG reached 15.72 and 0.006, respectively, in the filtered signal of one of the ECG recordings.","PeriodicalId":39974,"journal":{"name":"Journal of Integrated Circuits and Systems","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pre-processing of ECG signal based on multistage filters\",\"authors\":\"Mohammed Waheed\",\"doi\":\"10.29292/jics.v18i2.698\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a new approach was adopted in order to remove the artifacts present in the raw ECG signal. To realizing this process a multiple types of filters for a variety of types of noises have been applied to obtain the lowest possible noise. Initially, the ECG signal was filtered from the electromyography signal, and then the filtered signal was passed again on another filter for the purpose of removing its drift from the baseline. The effectiveness of the suggested approach has been assessed in comparison to the conventional ECG signal. Results of this study showed significantly less signaling noise than was present in the conventional signal. Overall, the signal to noise ratio and the mean square error of the filtered ECG reached 15.72 and 0.006, respectively, in the filtered signal of one of the ECG recordings.\",\"PeriodicalId\":39974,\"journal\":{\"name\":\"Journal of Integrated Circuits and Systems\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Integrated Circuits and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29292/jics.v18i2.698\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Integrated Circuits and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29292/jics.v18i2.698","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
Pre-processing of ECG signal based on multistage filters
In this paper, a new approach was adopted in order to remove the artifacts present in the raw ECG signal. To realizing this process a multiple types of filters for a variety of types of noises have been applied to obtain the lowest possible noise. Initially, the ECG signal was filtered from the electromyography signal, and then the filtered signal was passed again on another filter for the purpose of removing its drift from the baseline. The effectiveness of the suggested approach has been assessed in comparison to the conventional ECG signal. Results of this study showed significantly less signaling noise than was present in the conventional signal. Overall, the signal to noise ratio and the mean square error of the filtered ECG reached 15.72 and 0.006, respectively, in the filtered signal of one of the ECG recordings.
期刊介绍:
This journal will present state-of-art papers on Integrated Circuits and Systems. It is an effort of both Brazilian Microelectronics Society - SBMicro and Brazilian Computer Society - SBC to create a new scientific journal covering Process and Materials, Device and Characterization, Design, Test and CAD of Integrated Circuits and Systems. The Journal of Integrated Circuits and Systems is published through Special Issues on subjects to be defined by the Editorial Board. Special issues will publish selected papers from both Brazilian Societies annual conferences, SBCCI - Symposium on Integrated Circuits and Systems and SBMicro - Symposium on Microelectronics Technology and Devices.