脉冲调节器在最大功率传输模式下的工作特点,在其输出端存在蓄能器

IF 1.6 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
V. Y. Romashko, L. M. Batrak, O. O. Abakumova
{"title":"脉冲调节器在最大功率传输模式下的工作特点,在其输出端存在蓄能器","authors":"V. Y. Romashko, L. M. Batrak, O. O. Abakumova","doi":"10.20998/2074-272x.2023.6.11","DOIUrl":null,"url":null,"abstract":"Introduction. For the efficient use of non-traditional and renewable sources of electrical energy, it is necessary to ensure their operation at the maximum power point, which is possible if the load resistance is equal to the output resistance of the source. To match the load resistance with the output impedance of the source, a matching switching regulator is connected between the source and the load. Very often, the amount of energy received from such sources depends on external conditions. To ensure a uniform supply of electrical energy to the load, a battery operating in buffer mode is connected at the output of the switching regulator. Problem. In this case, the load of the switching regulator is the battery, and the input impedance of the regulator will perform the role of the load of the power source. This resistance depends on the voltage of the battery, the type of switching regulator and its mode of operation. In such cases, the maximum power extraction mode from the source can be provided by selecting the appropriate operating mode of the switching regulator. The aim of the work is to analyze the conditions and determine the modes under which the transfer of the maximum possible amount of electrical energy from the source to the battery is ensured, as well as the features of the switching regulator in these modes. Methods. For this purpose, the regulating characteristics of step-up and step-down switching regulators were determined and analyzed, taking into account the presence of an accumulator at their output. Taking into account that in the maximum power transmission mode, the output resistance of the source and the load resistance are of the same order of magnitude, when determining the regulating characteristics, the internal resistance of the source was taken into account. Results. As a result of the analysis of the obtained regulating characteristics, the conditions were determined under which the transfer of energy from the source to the battery is ensured, and the parameters of the operating mode of the switching regulator were determined, under which the maximum power will be taken from the source of electrical energy. Novelty. The originality of the work is the consideration of the internal resistance of the source of electrical energy in determining the regulating characteristics of pulse regulators. Practical value. The obtained results made it possible to indicate the appropriate range of battery voltages for different types of pulse regulators, as well as to give practical recommendations for choosing the mode of operation of the pulse regulator depending on its type, as well as the amount of voltage on the battery.","PeriodicalId":44198,"journal":{"name":"Electrical Engineering & Electromechanics","volume":"23 2","pages":"0"},"PeriodicalIF":1.6000,"publicationDate":"2023-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Features of the work of pulse regulators in the maximum power transmission mode, with the presence of an accumulator at their output\",\"authors\":\"V. Y. Romashko, L. M. Batrak, O. O. Abakumova\",\"doi\":\"10.20998/2074-272x.2023.6.11\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction. For the efficient use of non-traditional and renewable sources of electrical energy, it is necessary to ensure their operation at the maximum power point, which is possible if the load resistance is equal to the output resistance of the source. To match the load resistance with the output impedance of the source, a matching switching regulator is connected between the source and the load. Very often, the amount of energy received from such sources depends on external conditions. To ensure a uniform supply of electrical energy to the load, a battery operating in buffer mode is connected at the output of the switching regulator. Problem. In this case, the load of the switching regulator is the battery, and the input impedance of the regulator will perform the role of the load of the power source. This resistance depends on the voltage of the battery, the type of switching regulator and its mode of operation. In such cases, the maximum power extraction mode from the source can be provided by selecting the appropriate operating mode of the switching regulator. The aim of the work is to analyze the conditions and determine the modes under which the transfer of the maximum possible amount of electrical energy from the source to the battery is ensured, as well as the features of the switching regulator in these modes. Methods. For this purpose, the regulating characteristics of step-up and step-down switching regulators were determined and analyzed, taking into account the presence of an accumulator at their output. Taking into account that in the maximum power transmission mode, the output resistance of the source and the load resistance are of the same order of magnitude, when determining the regulating characteristics, the internal resistance of the source was taken into account. Results. As a result of the analysis of the obtained regulating characteristics, the conditions were determined under which the transfer of energy from the source to the battery is ensured, and the parameters of the operating mode of the switching regulator were determined, under which the maximum power will be taken from the source of electrical energy. Novelty. The originality of the work is the consideration of the internal resistance of the source of electrical energy in determining the regulating characteristics of pulse regulators. Practical value. The obtained results made it possible to indicate the appropriate range of battery voltages for different types of pulse regulators, as well as to give practical recommendations for choosing the mode of operation of the pulse regulator depending on its type, as well as the amount of voltage on the battery.\",\"PeriodicalId\":44198,\"journal\":{\"name\":\"Electrical Engineering & Electromechanics\",\"volume\":\"23 2\",\"pages\":\"0\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrical Engineering & Electromechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20998/2074-272x.2023.6.11\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering & Electromechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20998/2074-272x.2023.6.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

介绍。为了有效利用非传统和可再生的电能,有必要确保它们在最大功率点运行,如果负载电阻等于电源的输出电阻,这是可能的。为了使负载电阻与源的输出阻抗相匹配,在源和负载之间连接一个匹配的开关稳压器。通常,从这种来源获得的能量取决于外部条件。为了确保向负载提供均匀的电能,在开关调节器的输出端连接一个以缓冲模式工作的电池。问题。在这种情况下,开关稳压器的负载就是电池,稳压器的输入阻抗就会起到电源负载的作用。这个电阻取决于电池的电压、开关稳压器的类型及其工作模式。在这种情况下,可以通过选择开关稳压器的适当工作模式来提供源的最大功率提取模式。这项工作的目的是分析并确定在哪些模式下可以保证从电源向电池传输最大可能量的电能,以及在这些模式下开关稳压器的特性。方法。为此,确定和分析了升压和降压开关稳压器的调节特性,并考虑了其输出端存在蓄能器。考虑到在最大功率传输方式下,源的输出电阻与负载电阻在同一数量级,在确定调节特性时,考虑了源的内阻。结果。通过对所获得的调节特性的分析,确定了保证能量从电源向电池传递的条件,确定了开关稳压器的工作模式参数,在此条件下从电能源获取最大功率。新鲜事物。这项工作的独创性在于在确定脉冲调节器的调节特性时考虑了电能源的内阻。实用价值。所获得的结果使得有可能指出不同类型的脉冲调节器的适当电池电压范围,以及根据其类型选择脉冲调节器的操作模式给出实用建议,以及电池上的电压量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Features of the work of pulse regulators in the maximum power transmission mode, with the presence of an accumulator at their output
Introduction. For the efficient use of non-traditional and renewable sources of electrical energy, it is necessary to ensure their operation at the maximum power point, which is possible if the load resistance is equal to the output resistance of the source. To match the load resistance with the output impedance of the source, a matching switching regulator is connected between the source and the load. Very often, the amount of energy received from such sources depends on external conditions. To ensure a uniform supply of electrical energy to the load, a battery operating in buffer mode is connected at the output of the switching regulator. Problem. In this case, the load of the switching regulator is the battery, and the input impedance of the regulator will perform the role of the load of the power source. This resistance depends on the voltage of the battery, the type of switching regulator and its mode of operation. In such cases, the maximum power extraction mode from the source can be provided by selecting the appropriate operating mode of the switching regulator. The aim of the work is to analyze the conditions and determine the modes under which the transfer of the maximum possible amount of electrical energy from the source to the battery is ensured, as well as the features of the switching regulator in these modes. Methods. For this purpose, the regulating characteristics of step-up and step-down switching regulators were determined and analyzed, taking into account the presence of an accumulator at their output. Taking into account that in the maximum power transmission mode, the output resistance of the source and the load resistance are of the same order of magnitude, when determining the regulating characteristics, the internal resistance of the source was taken into account. Results. As a result of the analysis of the obtained regulating characteristics, the conditions were determined under which the transfer of energy from the source to the battery is ensured, and the parameters of the operating mode of the switching regulator were determined, under which the maximum power will be taken from the source of electrical energy. Novelty. The originality of the work is the consideration of the internal resistance of the source of electrical energy in determining the regulating characteristics of pulse regulators. Practical value. The obtained results made it possible to indicate the appropriate range of battery voltages for different types of pulse regulators, as well as to give practical recommendations for choosing the mode of operation of the pulse regulator depending on its type, as well as the amount of voltage on the battery.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electrical Engineering & Electromechanics
Electrical Engineering & Electromechanics ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
2.40
自引率
50.00%
发文量
53
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信