单侧截肢者的声发射分析(AEA)作为未来骨科技术的质量工具来评估与膝关节炎相关的调整假体

Q4 Engineering
Joerg Subke, Adeline Keller, Hermawan Hermawan, Michael Schmeiler, Benedict Schneider, Hans-Joachim Schwalbe
{"title":"单侧截肢者的声发射分析(AEA)作为未来骨科技术的质量工具来评估与膝关节炎相关的调整假体","authors":"Joerg Subke, Adeline Keller, Hermawan Hermawan, Michael Schmeiler, Benedict Schneider, Hans-Joachim Schwalbe","doi":"10.1515/cdbme-2023-1179","DOIUrl":null,"url":null,"abstract":"Abstract In orthopaedic technology unilateral leg amputees are provided with prosthesis which are attached through a shaft to the remaining part of the leg. The prosthesis legs are built according to manufacturer’s specifications and get adjusted to the individual needs through motion analysis. If the prosthesis is not adjusted correctly to the individual needs of the user, the chance for development of arthritis in the remaining knee joint is greatly increased. The goal of this paper is to develop a procedure based on AEA to detect signs of arthritis in the remaining knee joint early and the base of a procedure for a future assessment of the quality of the care. The measurement system consists of the AEA - measurement device, a force plate to measure ground reaction forces, two strain gauges which are attached to handles on a test rig and two video cameras which record the movement from frontal and sagittal view. The amputee performs a standard movement in the test rig which consists of three knee bends in ten seconds while wearing the prosthesis legs. The test rig is provided so the amputee can support themselves using arms and hands as prosthesis’ support during the extension phase of the knee bend. The posture and load of the knee joint during the movement is analyzed with the video and force data. The ground reaction forces show the load distribution between the remaining leg and the prosthesis and its support during the movement. The hand forces give clues how well the amputee can balance and which arm is favored under load. By combining kinematic data and AEA the state of the load transfer zones can be evaluated. Thus, it’s possible to examine the remaining knee joint for defects and evaluate the quality of the prosthesis adjustment.","PeriodicalId":10739,"journal":{"name":"Current Directions in Biomedical Engineering","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Acoustic Emission Analysis (AEA) in unilateral leg amputees as a future quality tool in orthopaedic technology to evaluate the adjusted prosthesis in relation to gonarthritis\",\"authors\":\"Joerg Subke, Adeline Keller, Hermawan Hermawan, Michael Schmeiler, Benedict Schneider, Hans-Joachim Schwalbe\",\"doi\":\"10.1515/cdbme-2023-1179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract In orthopaedic technology unilateral leg amputees are provided with prosthesis which are attached through a shaft to the remaining part of the leg. The prosthesis legs are built according to manufacturer’s specifications and get adjusted to the individual needs through motion analysis. If the prosthesis is not adjusted correctly to the individual needs of the user, the chance for development of arthritis in the remaining knee joint is greatly increased. The goal of this paper is to develop a procedure based on AEA to detect signs of arthritis in the remaining knee joint early and the base of a procedure for a future assessment of the quality of the care. The measurement system consists of the AEA - measurement device, a force plate to measure ground reaction forces, two strain gauges which are attached to handles on a test rig and two video cameras which record the movement from frontal and sagittal view. The amputee performs a standard movement in the test rig which consists of three knee bends in ten seconds while wearing the prosthesis legs. The test rig is provided so the amputee can support themselves using arms and hands as prosthesis’ support during the extension phase of the knee bend. The posture and load of the knee joint during the movement is analyzed with the video and force data. The ground reaction forces show the load distribution between the remaining leg and the prosthesis and its support during the movement. The hand forces give clues how well the amputee can balance and which arm is favored under load. By combining kinematic data and AEA the state of the load transfer zones can be evaluated. Thus, it’s possible to examine the remaining knee joint for defects and evaluate the quality of the prosthesis adjustment.\",\"PeriodicalId\":10739,\"journal\":{\"name\":\"Current Directions in Biomedical Engineering\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Directions in Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/cdbme-2023-1179\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Directions in Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cdbme-2023-1179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

在骨科技术中,为单侧腿截肢者提供假体,假体通过轴连接到腿的其余部分。假腿是根据制造商的规格制造的,并通过运动分析来调整个人需求。如果假体没有正确地调整到使用者的个人需求,那么在剩余的膝关节中发展关节炎的机会就会大大增加。本文的目的是开发一种基于AEA的程序,以早期检测剩余膝关节的关节炎迹象,并为将来评估护理质量的程序奠定基础。测量系统由AEA -测量装置、测量地面反作用力的测力板、连接在试验台手柄上的两个应变片和两个从正面和矢状视图记录运动的摄像机组成。截肢者戴着假腿,在测试台上做一个标准的动作,包括在十秒钟内弯曲三次膝盖。提供测试平台,以便截肢者可以在膝关节弯曲的延伸阶段使用手臂和手作为假体的支持来支撑自己。利用视频和受力数据分析膝关节在运动过程中的姿态和负荷。地面反作用力显示了运动过程中残肢与假肢及其支撑之间的载荷分布。手的力量提供了截肢者平衡能力的线索,以及哪只手臂在负荷下更受欢迎。将运动学数据与AEA相结合,可以评估载荷传递区的状态。因此,可以检查剩余膝关节的缺陷并评估假体调整的质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Acoustic Emission Analysis (AEA) in unilateral leg amputees as a future quality tool in orthopaedic technology to evaluate the adjusted prosthesis in relation to gonarthritis
Abstract In orthopaedic technology unilateral leg amputees are provided with prosthesis which are attached through a shaft to the remaining part of the leg. The prosthesis legs are built according to manufacturer’s specifications and get adjusted to the individual needs through motion analysis. If the prosthesis is not adjusted correctly to the individual needs of the user, the chance for development of arthritis in the remaining knee joint is greatly increased. The goal of this paper is to develop a procedure based on AEA to detect signs of arthritis in the remaining knee joint early and the base of a procedure for a future assessment of the quality of the care. The measurement system consists of the AEA - measurement device, a force plate to measure ground reaction forces, two strain gauges which are attached to handles on a test rig and two video cameras which record the movement from frontal and sagittal view. The amputee performs a standard movement in the test rig which consists of three knee bends in ten seconds while wearing the prosthesis legs. The test rig is provided so the amputee can support themselves using arms and hands as prosthesis’ support during the extension phase of the knee bend. The posture and load of the knee joint during the movement is analyzed with the video and force data. The ground reaction forces show the load distribution between the remaining leg and the prosthesis and its support during the movement. The hand forces give clues how well the amputee can balance and which arm is favored under load. By combining kinematic data and AEA the state of the load transfer zones can be evaluated. Thus, it’s possible to examine the remaining knee joint for defects and evaluate the quality of the prosthesis adjustment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Directions in Biomedical Engineering
Current Directions in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
0.90
自引率
0.00%
发文量
239
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信