{"title":"生物医学应用的超宽带分形环形天线","authors":"Ilyas Saleem, Umair Rafique, Shobit Agarwal, Hüseyin Şerif SAVCI, Syed Muzahir Abbas, Subhas Mukhopadhyay","doi":"10.1155/2023/5515263","DOIUrl":null,"url":null,"abstract":"In this paper, an efficient, coplanar waveguide (CPW)-fed printed circular ring fractal ultra-wideband (UWB) antenna is presented for biomedical applications. In UWB technology, short-range wireless communication is possible with low transceiving power, a characteristic that is particularly advantageous in the context of microwave and millimeter-wave (mmWave) medical imaging. In the proposed antenna configuration, the UWB response is achieved by introducing wedged slots in the radiating patch, designed on a low-loss substrate. A CPW partial ground plane is truncated from the edges to optimize the antenna impedance. Experimental results indicate the antenna’s robust performance across the frequency range of 3.2–20 GHz. The well-matched measured and simulated results confirm our contribution’s employability. Furthermore, a time-domain study offers valuable insights into how the antenna responds to transient signals, highlighting its responsiveness and adaptability to biomedical applications.","PeriodicalId":54392,"journal":{"name":"International Journal of Antennas and Propagation","volume":"32 1","pages":"0"},"PeriodicalIF":1.2000,"publicationDate":"2023-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Ultra-Wideband Fractal Ring Antenna for Biomedical Applications\",\"authors\":\"Ilyas Saleem, Umair Rafique, Shobit Agarwal, Hüseyin Şerif SAVCI, Syed Muzahir Abbas, Subhas Mukhopadhyay\",\"doi\":\"10.1155/2023/5515263\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an efficient, coplanar waveguide (CPW)-fed printed circular ring fractal ultra-wideband (UWB) antenna is presented for biomedical applications. In UWB technology, short-range wireless communication is possible with low transceiving power, a characteristic that is particularly advantageous in the context of microwave and millimeter-wave (mmWave) medical imaging. In the proposed antenna configuration, the UWB response is achieved by introducing wedged slots in the radiating patch, designed on a low-loss substrate. A CPW partial ground plane is truncated from the edges to optimize the antenna impedance. Experimental results indicate the antenna’s robust performance across the frequency range of 3.2–20 GHz. The well-matched measured and simulated results confirm our contribution’s employability. Furthermore, a time-domain study offers valuable insights into how the antenna responds to transient signals, highlighting its responsiveness and adaptability to biomedical applications.\",\"PeriodicalId\":54392,\"journal\":{\"name\":\"International Journal of Antennas and Propagation\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Antennas and Propagation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/5515263\",\"RegionNum\":4,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Antennas and Propagation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/5515263","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Ultra-Wideband Fractal Ring Antenna for Biomedical Applications
In this paper, an efficient, coplanar waveguide (CPW)-fed printed circular ring fractal ultra-wideband (UWB) antenna is presented for biomedical applications. In UWB technology, short-range wireless communication is possible with low transceiving power, a characteristic that is particularly advantageous in the context of microwave and millimeter-wave (mmWave) medical imaging. In the proposed antenna configuration, the UWB response is achieved by introducing wedged slots in the radiating patch, designed on a low-loss substrate. A CPW partial ground plane is truncated from the edges to optimize the antenna impedance. Experimental results indicate the antenna’s robust performance across the frequency range of 3.2–20 GHz. The well-matched measured and simulated results confirm our contribution’s employability. Furthermore, a time-domain study offers valuable insights into how the antenna responds to transient signals, highlighting its responsiveness and adaptability to biomedical applications.
期刊介绍:
International Journal of Antennas and Propagation publishes papers on the design, analysis, and applications of antennas, along with theoretical and practical studies relating the propagation of electromagnetic waves at all relevant frequencies, through space, air, and other media.
As well as original research, the International Journal of Antennas and Propagation also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.