高效液相色谱-串联质谱法测定尿中阿糖胞苷的毒性动力学和排泄研究

Q3 Chemistry
İbrahim DANİŞ, Ayşegül GÖLCÜ, Durişehvar ÜNAL
{"title":"高效液相色谱-串联质谱法测定尿中阿糖胞苷的毒性动力学和排泄研究","authors":"İbrahim DANİŞ, Ayşegül GÖLCÜ, Durişehvar ÜNAL","doi":"10.18596/jotcsa.1190202","DOIUrl":null,"url":null,"abstract":"Cytarabine (Cyt) (also known as cytosine arabinoside (ara-C)) used in the treatment of acute myeloid leukemia (AML), acute lymphocytic leukemia (ALL). CYT applied in high doses for treatment can cause renal failure. Monitoring excreted urine drug levels can help kidney failure. For this reason, a method was developed and validated by HPLC-MSMS for urine CYT analysis, which is not included in the literature. In this study, a liquid chromatography (HPLC) with triple quadrupole Mass Spectrometric (MS/MS) method developed for the determination of Cyt from urine for toxicokinetic evaluation. Positive MRM mode selected for the quantification of Cyt. The product and major fragment ion for Cyt 244.0 > 112.0 m/z, for IS 198.0 > 152.0 m/z. The optimal MS parameters for Cyt and IS are as follows Fragmentor 80 V, 70 V, Collision energy, 6, 9 respectively. A novel simple, high-throughput and highly sensitive HPLC-MS/MS method was successfully developed and validated for the determination of Cyt from urine. The developed method has a simple one-step extraction method and a short run time (2.0 minutes) for analysis. The proposed method could be practical and reliable for excretion and toxicokinetic studies and as well as the Therapeutic Drug Monitoring study in humans without an invasive route for Cyt.","PeriodicalId":17402,"journal":{"name":"Journal of the Turkish Chemical Society, Section A: Chemistry","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cytarabine determination from urine for Toxicokinetic and Excretion studies by High- Performance Liquid Chromatography-Tandem Mass Spectrometry\",\"authors\":\"İbrahim DANİŞ, Ayşegül GÖLCÜ, Durişehvar ÜNAL\",\"doi\":\"10.18596/jotcsa.1190202\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cytarabine (Cyt) (also known as cytosine arabinoside (ara-C)) used in the treatment of acute myeloid leukemia (AML), acute lymphocytic leukemia (ALL). CYT applied in high doses for treatment can cause renal failure. Monitoring excreted urine drug levels can help kidney failure. For this reason, a method was developed and validated by HPLC-MSMS for urine CYT analysis, which is not included in the literature. In this study, a liquid chromatography (HPLC) with triple quadrupole Mass Spectrometric (MS/MS) method developed for the determination of Cyt from urine for toxicokinetic evaluation. Positive MRM mode selected for the quantification of Cyt. The product and major fragment ion for Cyt 244.0 > 112.0 m/z, for IS 198.0 > 152.0 m/z. The optimal MS parameters for Cyt and IS are as follows Fragmentor 80 V, 70 V, Collision energy, 6, 9 respectively. A novel simple, high-throughput and highly sensitive HPLC-MS/MS method was successfully developed and validated for the determination of Cyt from urine. The developed method has a simple one-step extraction method and a short run time (2.0 minutes) for analysis. The proposed method could be practical and reliable for excretion and toxicokinetic studies and as well as the Therapeutic Drug Monitoring study in humans without an invasive route for Cyt.\",\"PeriodicalId\":17402,\"journal\":{\"name\":\"Journal of the Turkish Chemical Society, Section A: Chemistry\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Turkish Chemical Society, Section A: Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18596/jotcsa.1190202\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Turkish Chemical Society, Section A: Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18596/jotcsa.1190202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

摘要

阿糖胞苷(Cyt)(又称阿糖胞苷(ara-C))用于治疗急性髓性白血病(AML)、急性淋巴细胞白血病(ALL)。高剂量CYT用于治疗可引起肾功能衰竭。监测排出尿液的药物水平可以帮助治疗肾衰竭。因此,我们开发了一种尿液CYT分析的方法,并通过HPLC-MSMS进行了验证,该方法未在文献中包含。本研究建立了一种液相色谱-三重四极杆质谱(MS/MS)法测定尿液中Cyt的毒性动力学评价方法。选择阳性MRM模式定量Cyt。Cyt 244.0的产物和主要片段离子;112.0 m/z,适用于IS 198.0 >152.0 m / z。Cyt和IS的最佳MS参数分别为Fragmentor 80 V, 70 V, Collision energy, 6, 9。建立了一种简便、高通量、高灵敏度的高效液相色谱-质谱联用(HPLC-MS/MS)测定尿液中Cyt的方法。该方法一步提取方法简单,分析运行时间短(2.0分钟)。该方法对于人体排泄和毒性动力学研究以及治疗性药物监测研究具有实用性和可靠性,无需侵入性Cyt途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cytarabine determination from urine for Toxicokinetic and Excretion studies by High- Performance Liquid Chromatography-Tandem Mass Spectrometry
Cytarabine (Cyt) (also known as cytosine arabinoside (ara-C)) used in the treatment of acute myeloid leukemia (AML), acute lymphocytic leukemia (ALL). CYT applied in high doses for treatment can cause renal failure. Monitoring excreted urine drug levels can help kidney failure. For this reason, a method was developed and validated by HPLC-MSMS for urine CYT analysis, which is not included in the literature. In this study, a liquid chromatography (HPLC) with triple quadrupole Mass Spectrometric (MS/MS) method developed for the determination of Cyt from urine for toxicokinetic evaluation. Positive MRM mode selected for the quantification of Cyt. The product and major fragment ion for Cyt 244.0 > 112.0 m/z, for IS 198.0 > 152.0 m/z. The optimal MS parameters for Cyt and IS are as follows Fragmentor 80 V, 70 V, Collision energy, 6, 9 respectively. A novel simple, high-throughput and highly sensitive HPLC-MS/MS method was successfully developed and validated for the determination of Cyt from urine. The developed method has a simple one-step extraction method and a short run time (2.0 minutes) for analysis. The proposed method could be practical and reliable for excretion and toxicokinetic studies and as well as the Therapeutic Drug Monitoring study in humans without an invasive route for Cyt.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.60
自引率
0.00%
发文量
81
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信